검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 154

        61.
        2017.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the present study, single-phase heat transfer characteristics for downstream flow in the support grid of 6×6 rod bundle were investigated. It has been known that a turbulence generation due to a support grid with split mixing vanes enhances heat transfer in rod bundle but its heat transfer enhancement actually affects to relatively shorter distance. On the other hand, it has been also turned out that a support grid with large scale vortex flow (LSVF) mixing vanes results in heat transfer enhancement to a longer distance. Based on the results of literatre survey, single-phase water heat transfer experiments were performed for Reynolds numbers at around 30,000, and the heat transfer enhancement effect with both i) the split mixing vanes and ii) the LSVF mixing vanes was compared in this study. The key results showed that the effect of heat transfer enhancement in rod bundle region by the split mixing vanes was maintained up to the length of 15Dh behind the spacer grid. For the Reynolds numbers at around 30,000, it was also observed that the effect using the LSVF mixing vanes was stronger at about 3% when compared to the case using the split mixing vanes only for the distance ranging from 1 to 15Dh behind the spacer grid.
        4,000원
        62.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The heat transfer characteristics of forced convection according to the geometric shapes with four rectangular blocks in a horizontal PCB channel was analyzed numerically using SST (Shear Stress Transport) turbulence model. As the boundary condition for CFD (Computational Fluid Dynamics) analysis, the inlet temperature and air velocity were respectively 300 K and 3.84 m/s and the heat flux of the block surface was 358 W/㎡. The shape factors of block were width, height, spacing and channel entrance height. As the results, the heat transfer rate was decreased as the width ratio (x/h) was increased, while it was increased as the height ratio (h/x) is increased. Also as the block spacing ratio (s/x) was increased, the heat transfer effects was not significantly affected. And as the channel entrance height ratio (H/x) was increased, the heat transfer performance was decreased.
        4,000원
        63.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the heat flow characteristics of wave heat exchanger was investigated by being applied to the white smoke reduction system. Through numerical analysis, the heat transfer and flow characteristics of the wave heat exchanger with the change of inlet condition of air-side and water-side were analyzed. To investigate the temperature, the absolute humidity, heat transfer rate, pressure drop and turbulence characteristics of the wave heat exchanger, the simulation analysis was conducted by using the commercial computational fluid dynamics software (Solidworks Flow Simulation) under uniform flow conditions. As the inflow rate of air decreased and the inflow temperature of water increased, the heat transfer coefficient of the wave heat exchanger decreased. When the experimental conditions of water-side were the same, the air outlet temperature and absolute humidity of the wave heat exchanger increased with increasing inflow rate of air. To reduce the white smoke, the air outlet temperature and absolute humidity of the wave heat exchanger must be reduced. Therefore, the lower the air velocity and the water inflow temperature into the wave heat exchanger, the more effective it is.
        4,000원
        64.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES :Conductive and convective heat transfer simulations for an asphalt mixture were made by using discrete element method (DEM) and similarity principle.METHODS :In this research, virtual specimens composed of discrete element method particles were generated according to four different predetermined particle size distribution curves. Temperature variations of the four different particles for a given condition were estimated and were compared with measurements and analytical solutions.RESULTS :The virtual specimen with mixed particles and with the smallest particle show very good agreement with laboratory test results and analytical solutions. As particle size decreases, better heat transfer simulation can be performed due to smaller void ratio and more contact points and areas. In addition, by utilizing the similarity principle of thermal properties and corresponding time unit, analytical time can be drastically reduced.CONCLUSIONS :It is concluded that the DEM asphalt mixture specimens with similarity principle could be used to predict the temperature variation for a given condition. It is observed that the void ratio has critical effect on prediction of temperature variation. Comparing the prediction for a 4 mm particle specimen with a mixed particle specimen, it is also concluded that predicting the mixed particle specimen temperature is much more efficient considering the number of particles that are directly associated with computational time in DEM analysis.
        4,000원
        65.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a direct contact membrane module was manufactured to be used in a pilot scale membrane distillation process to treat 3 m3/day of the digestate produced from anaerobic digestion of livestock manure. In order to investigate the performance of the membrane module, permeate flux was measured with and without spacer inside the module under various condition of temperature difference and cross flow velocity (CFV) through the membrane surfaces. Flux recovery rate after chemical cleaning was also investigated by applying three different cleaning methods. Additionally, thermal energy consumption was theoretically simulated based on actual pilot plant operation conditions. As results, we observed flux of the module with spacer was almost similar to the theoretically predicted value because the installation of spacer reduced the channeling effect inside the module. Under the same operating condition, the permeate flux also increased with increasing temperature difference and CFV. As a result of chemical in-line cleaning using NaOCl and citric acid for the fouled membranes, the recovery rate was 83.7% compared to the initial flux when NaOCl was used alone, and 87% recovery rate was observed when only citric acid was used. However, in the case of using only citric acid, the permeate flux was decreased at a rapid rate. It seemed that a cleaning by NaOCl was more effective to recover the flux of membrane contaminated by the organic matter as compared to a cleaning by citric acid. The total heat energy consumption increased with increasing CFV and temperature difference across the membrane. Thus, further studies should be intensively conducted to obtain a high permeate flux while keeping the energy consumption to a minimum for a practical application of membrane distillation process to treat wastewater.
        4,000원
        66.
        2017.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Ablative material in a rocket nozzle is exposed to high temperature combustion gas, thus undergoes complicated thermal/chemical change in terms of chemical destruction of surface and thermal decomposition of inner material. Therefore, method for conjugate analysis of thermal response inside carbon/phenolic material including rocket nozzle flow, surface chemical reaction and thermal decomposition is developed in this research. CFD is used to simulate flow field inside nozzle and conduction in the ablative material. A change in material density and a heat absorption caused by the thermal decomposition is considered in solid energy equation. And algebraic equation under boundary layer assumption is used to deduce reaction rate on the surface and resulting destruction of the surface. In order to test the developed method, small rocket nozzle is solved numerically. Although the ablation of nozzle throat is deduced to be higher than the experiment, shape change and temperature distribution inside material is well predicted. Error in temperature with experimental results in rapid heating region is found to be within 100 K.
        4,000원
        67.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we investigated to the heat transfer performance of coating nano-structure with various shapes and patterns on the heat transfer surface. As a result of the measurement of the 3D nano shape, it was confirmed that the roughness generally increases when the adhesive is sprayed on the coating surface and finished durability experiment. In the case of TEOS adhesive, the roughness increased by 0.074 ㎛, 0.012 ㎛ and 0.015 ㎛, and the contact angle decreased 12.64°, 1.31°, 9.84° at the coating time of 120 seconds, 180 seconds and 240 seconds, respectively. In the case of PVA adhesive, the roughness increased by 0.069 ㎛, 0.056 ㎛ and 0.03 ㎛, and the contact angle decreased 2.85°, 4.82°, 6.96° at the coating time of 120 seconds, 180 seconds and 240 seconds, respectively. In the case of DGEBF adhesive, the roughness increased by 0.042 ㎛, 0.053 ㎛ and 0 ㎛, and the contact angle decreased 0.81° at the coating time of 120 seconds, increased 4.82°, 6.96° at the coating time of 180 seconds and 240 seconds, respectively. As a result, the durability tends to decrease as more nano-structures are deposited, and 3D nano shapes, contact angles and SEM photographs showed that the performance of the PVA adhesive was superior among the three adhesives.
        4,000원
        68.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Numerical models of composite floor systems with various thickness of phase change material and sizes of circular spacers were developed based on finite element analysis. In order to perform a heat transfer analysis, thermal properties of steels were determined and those of phase change material were estimated from experiment results. In addition, the thermal insulation performance of composite floor systems with respect to different thickness of phase change material and sizes of circular spacers was predicted. To verify the validity of analysis, analysis results were compared with vertical furnace fire test results of equivalent conditions. As a result, available thicknesses of phase change material and sizes of circular spacers were proposed to satisfy the thermal insulation criteria of Korean Standards.
        4,000원
        69.
        2017.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The heat transfer of Jet impingement is a very effective technique for exchanging high heat fluxs between a heated plate and a fluid. The purpose of current investigation is to carry out the experiment in order to study heat transfer characteristics between a vertical round water jet and a horizontal surface for different flow rates and geometric conditions. The effect of flow rates on heat transfer were investigated. The data obtained in this study are represented in terms of Nusselt number as a function of Reynolds and Peclet numbers. The correlation for the Nusselts number in terms of the Peclet number and  was obtained. The proposed correlation predicts the current data of heat transfer very well.
        4,000원
        70.
        2017.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        1차원 등엔트로피 모델과 통합된 경계층 적분법은 초음속 노즐의 설계과정에서 내열재 표면의 열전달을 예측하는데 효과 적으로 사용되고 있지만 노즐 목과 같이 2차원 효과와 경계층과 노즐 코어유동의 상호작용이 발생하는 지점에서는 경계층 외부유동 해석의 부정확성으로 해석의 정확도가 감소한다. 따라서 본 연구에서는 경계층 적분법을 이용한 열전달 예측의 정 확도를 향상시키기 위해 CFD를 이용하여 2차원 효과와 노즐 코어유동의 상호작용이 고려된 경계층 외부유동 조건을 도출 하고 이를 경계조건으로 하는 해석기법을 개발하였다. 오일러 모델과 SST k-ω 모델을 CFD로 해석하여 경계조건으로 적용 했으며 계산방법을 검증하기 위해 선행문헌의 실험노즐에 대해 해석을 수행하였다. 계산 결과 CFD를 통해 경계층 외부유동 조건을 도출한 해석에서 노즐 열전달의 정확도가 향상되는 것을 확인하였으며 특히 노즐 목 후방과 팽창부에서의 차이가 크 게 나타났다. SST k-ω모델로 도출된 계산결과는 1차원 등엔트로피 모델과 비교 시 팽창부에서 실험결과와의 오차가 16% 감소하였다. 본 연구에서 개발된 해석기법은 향후 로켓노즐의 내열설계에 유용하게 사용될 것으로 평가된다.
        4,000원
        72.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we designed the 3-dimensional tire mold according to the A automobile company’s tire model, and analysed the distribution of temperature of mold using the numerical method when the heat flux and heat transfer time at the surface of tire mold were changed. A analysis region of mold was the 1/16 of entire mold, and the grid number was about more than 880 thousand. In order to analyze the temperature change of mold, the thinnest part of the mold was chosen as the research object, and then the temperature of 6 points on the vertical downward direction of the thinnest part was analyzed with the time change. While the numerical condition was that heat flux was 321,200 W/m2, 440,000 W/m2 and 880,000 W/m2, and measuring time was 0.1 second, 0.2 second, 0.5 second and 1 second, respectively. As a result, the temperature difference between the surface temperature and the lowest temperature of mold was 7.3℃ when the heat transfer time was 0.1 second. Also, the minimum temperature difference was almost 0.11℃ when the heat transfer increased to 1 second. It can be explained that the main material of tire mold was aluminum and its thermal conductivity was high (k=140 W/m·K). In addition, when the heat transfer time was more than 1 second, the heat flux of mold surface will be transmitted at the inside of the thinnest part, and the heat transfer will be a marked difference according to the shape of the thinnest part.
        4,000원
        73.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        단동 이중비닐하우스에서 수막에 의한 열전달 특성 및 가온효과를 구명하기 위하여 작물이 재배되는 수막온실의 실내외 기온과 수막의 수온 등을 계측하였고, 단위 피복면적당 수막에 의한 총 공급열량, 열관류율, 관류열량, 온실 내부로 전달되는 열량비율 변화를 비교·분석하였다. 1중과 2중사이의 기온은 외부기온보다는 수막유량과 공급수온에 따라 결정되는 것으로 나타났다. 수막유량이 증가할수록, 공급수온이 높을수록 수막과 2중 하우스 내부와의 열관류율(UW-IN)은 유의하게 증가하는 경향을 보였다. 그러나 수막유량과 공급수온이 일정조건(수 막유량 0.00266L·m-2·s-1, 공급수온 19.8oC) 이상에서는 UW-IN 값이 10W·m-2·oC-1 정도로 수렴되는 것으로 나타났다. 수막과 1·2중 공기 사이의 열관류율(UW-B)의 경우에도 수막유량 및 공급수온에 따라 증가하는 경향을 보였으나, 경향성은 상대적으로 작은 것으로 분석되었다. UW-B는 연구자에 따라 전체적으로 큰 차이를 보이고 있으며, 본 연구에서는 3.27~4.44W·m-2·oC-1의 범위를 보였다. 수막에 의한 총 공급열량(QW)과 온실 내외부로 전달 되는 관류열량(QW-IN, QW-B)의 경우, QW 값이 QW-IN과 QW-B의 합과 매우 유사하게 일치하고 있어 본 연구에서 제시한 결과가 신뢰성이 있음을 확인할 수 있었다. 수막에 의해 내부공기를 가열하는데 사용되는 열량은 최대 57% 수준으로 분석되었고, 우리나라 수막재배온실의 경우 약 22~28% 수준으로 판단된다. 본 연구는 농업인이 실제 사용하는 수막온실과 가장 유사한 조건에서 수막에 의한 온도변화, 열관류율과 관류열량을 계량화함으로써 향후 경제적인 수막온실 설계 시 활용할 수 있을 것으로 기대된다.
        4,000원
        76.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Flexible two-phase thermosyphons are devices that can transfer large amounts of heat flux with boiling and condensation of working fluid resulting from small temperature differences. A flexible two-phase thermosyphon consists of a evaporator, an insulation unit, and a condenser. The working fluid inside the evaporator is evaporated by heating the evaporator in the lower part of the flexible two-phase thermosyphon and the evaporated steam rises to the condenser in the upper part to transfer heat in response to the cooling fluid outside the tube. The resultant condensed working fluid flows downward along the inside surface of the tube due to gravity. These processes form a cycle. Using R134a refrigerant as the working fluid of a loop type flexible two-phase thermosyphon heat exchanger, an experiment was conducted to analyse changes in boiling heat transfer performances according to differences in the temperature of the oil for heating of the evaporator, the temperature variations of the refrigerant, and the mass flows. According to the results of the present study, the circulation rate of the refrigerant increased and the pressure in the evaporator also increased proportionally as the temperature of the oil in the evaporator increased. In addition, the heat transfer rate of the boiler increased as the temperature of the oil in the evaporator increased.
        4,000원
        77.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was investigated heat flow and heat transfer coefficient characteristics of around tube when changing the tube arrangement type and heat transfer area. When  ≒1∼4, convective heat transfer coefficient of staggered and aligned arrangement was increased. Growth rate of the heat transfer coefficient becomes smaller in case of ≒5∼8 because a change in the turbulence was very small. At the staggered arrangement, all tubes were always arranged in front of the open passage between the back of the tube. Then, the entire surface area of the tube was exposed to the main flow. Thus growth rate of heat transfer coefficient appear larger than aligned arrangement.
        4,000원
        78.
        2016.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: The national highways and expressways in Korea constitute a total length of 17,951 km. Of this total length of pavement, the asphalt pavement has significantly deteriorated, having been in service for over 10 years. Currently, hot in-place recycling (HIR) is used as the rehabilitation method for the distressed asphalt pavement. The deteriorated pavement becomes over-heated, however, owing to uncontrolled heating capacity during the pre-heating process of HIR in the field. METHODS: In order to determine the appropriate heating method and capacity of the pre-heater at the HIR process, the heating temperature of asphalt pavement is numerically simulated with the finite element software ABAQUS. Furthermore, the heating transfer effects are simulated in order to determine the inner temperature as a function of the heating system (IR and wire). This temperature is ascertained at 300 ℃, 400℃, 500℃, 600℃, 700°℃, and 800℃ from a slab asphalt specimen prepared in the laboratory. The inner temperature of this specimen is measured at the surface and five different depths (1 cm, 2 cm, 3 cm, 4 cm, and 5 cm) by using a data logger. RESULTS: The numerical simulation results of the asphalt pavement heating temperature indicate that this temperature is extremely sensitive to increases in the heating temperature. Moreover, after 10 min of heating, the pavement temperature is 36%~38% and 8%~10% of the target temperature at depths of 25 mm and 50 mm, respectively, from the surface. Therefore, in order to achieve the target temperature at a depth of 50 mm in the slab asphalt specimen, greater heating is required of the IR system compared to that of the gas. CONCLUSIONS : Numerical simulation, via the finite element method, can be readily used to analyze the appropriate heating method and theoretical basis of the HIR method. The IR system would provide the best heating method and capacity of HIR heating processes in the field.
        4,000원
        79.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 NO96 화물창의 BOG(boil off gas), BOR(boil off rate)을 감소시키기 위한 노력으로 단열재료 및 단열층을 변화시켜서 개발된 NO96-GW, NO96-L03의 방열구조에 대해서 BOG, BOR 값을 계산하고 단열성능을 비교․평가하였다. 두 가지의 변형된 NO96 모델을 기존의 NO96 방열과 단열층 및 단열재료의 차이점을 비교하고, 각각의 열저항 및 BOG/BOR 값의 비교 결과를 제시하였다. 열저항 값은 유한요소해석법을 이용하여 계산되었으며, 준정적 열평형 상태를 가정하여 열유속과 온도분포를 통하여 단열성능을 비교하였다. 계산에 사용된 화물창의 모든 재료물성치는 온도 의존값으로서 반영하여 -163oC에서의 극저온 상태에서 특성을 반영되었다. 각 화물창의 BOG, BOR 계산은 국부 열전달 해석을 통해 방열판에서 발생하는 열유속을 계산하고, 등가모델을 적용하여 계산하는 과정으로 수행되었으며, 그 결과를 각 화물창의 단열성능을 비교평가하기 위해서 검토하였다.
        4,000원
        80.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The heat transfer characteristics of a louver fin for a radiator are numerically analyzed to investigate the performance of radiator for automotive. The commercial code FLUENT is utilized to simulate a louver fin to analyze both the flow fields of air and the solid region of lover fin. The numerical analysis is performed with the variation of air mass flow rate. The results show that as mass flow rate increases, louver fin efficiency is nearly constant. The correlation of the average Nu is derived. The results of numerical study is useful in louvered fin design.
        4,000원
        1 2 3 4 5