        검색결과 154

        101.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Computational results with pseudoplastic fluid flows for fully developed non-Newtonian laminar flows have been obtained. Those consist of the product of friction factor and Modified Reynolds number and Nusselt numbers with respect to the shear rate parameter in an annular pipe. The numerical results of the product of friction factor and Reynolds numbers and the Nusselt numbers for both Newtonian region and the power law region were compared with previously published asymptotic results, respectively. In the present calculations, the product of friction factor and Newtonian Reynolds numbers for pseudoplastic fluid at power law region in annular pipe is 180% less than that for Newtonian fluid. For power law fluids with different power law flow indices, the difference of the product of friction factor and power law Reynolds number between previous and the present results at the power law region is within 0.20%. The solutions also show the effect of the shear rate parameter on the Nusselt number and about 11% increase of Nusselt number at the power region.
        4,000원
        102.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 국내 상업용 온실 피복재의 관류열전달계수를 산정히는데 필요한 기초자료를 제공하기 위하여 최근 국내에 많이 보급되어 사용되고 있는 플라스틱필름으로 피복된 온실에 대해 관류열량을 측정하고 관류열전달계수의 변화를 분석하였으며 그 결과를 요약하면 다음과 같다. 온실 내외부 온도차에 따른 관류열전달계수의 변화를 분석한 결과 피복의 층수에 따라 안정된 관류열전달계수를 나타내게 되는 온실 내외부 온도차의 값이 다르게 나타났기 때문에 온실 피복재에 대한 관류열전달계수를 결정할 때에는 피복층수별로 안정된 값을 나타내는 온실 내외부 온도차 범위에서의 관류열전달계수를 채택하여야할 것이다. 온도차이에 따른 관류열전달계수의 변화 경향은 기존의 연구결과와 잘 일치하였으나 안정된 값을 나타내는 온도차이의 구체적인 값은 다르게 나타났기 때문에 이에 대한 추가적인 연구가 필요할 것으로 판단된다. 풍속에 따른 관류열전달계수의 증가율은 연구자에 따라 많은 차이가 있음을 알 수 있었으며, 이중피복온실이나 커튼을 설치한 온실과 같이 보온성을 높인 온실은 일중피복온실에 비해 풍속에 따른 관류열 손실이 더 작다는 사실을 확인할 수 있었다. 관류열전달계수의 기존 연구결과들을 분석한 결과 연구자에 따라 값이 차이가 있었기 때문에 국내 온실의 정확한 난방부하량을 산정하는데 필요한 적절한 관류열전달계수를 제시하기 위해서는 우선 측정을 위한 표준화된 환경기준이 마련될 필요가 있으며, 또한 국내에서 실제로 사용되고 있는 주요 피복재별로 구체적인 관류열전달계수가 구해져야 할 것이다.
        4,000원
        103.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Experimental measurements of flame shape and heat transfer characteristics were performed for impinged inverse diffusion flame(IDF) using propane as a fuel. The purpose of this study is to identify the favorable co-axial inverse diffusion flame structure for impingement heating. The flame consisted of an entrainment zone and mixing and combustion zone. The heat flux which represents heat transfer rate is measured by using a heat flux sensor that is located at the center of the impingement plate. The inverse diffusion flame structure has been classified into six modes. In these modes, several favorable flames for impingement heating were identified. In this study, the parameters are overall equivalent ratio(Φ), nozzle to impingement plate distance(h/d), vertical distance from the stagnation point and Reynolds number(Re) of combustion air.
        4,000원
        104.
        2010.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        고준위 방사성 폐기물 처분장의 경우 폐기물의 방사성 붕괴에 의해 열이 발생되며, 암반을 통한 열전달 에 의해 처분장 주변 환경이 변화됨으로써 처분장의 안전성에 영향을 미칠 수 있다. 그러므로 지하 처분장 대기의 열전달계수를 결정하는 것은 매우 중요하다. 이에 본 연구에서는 Korea Atomic Energy Research Institute Underground Research Tunnel (KURT)에서 내부 환경 인자들의 측정을 통해 강제대류시 열전달계수를 산정하였다. 실험을 위해 KURT 내 히터구간의 막장 벽면에는 길이 2 m, 용량 5 kw의 히터를 삽 입하여 암반 내부를 90℃로 가열하였고, 외부와 연결된 급기용 팬에 의해 신선한 공기를 공급하였다. 연구 결과, 외부공기 공급 후 히터구간 대기의 기류속도는 평균 0.81 m/s로 측정되었고 레이놀즈수는 약 310,000 340,000의 값을 나타냈다. 그리고 강제대류조건에서 히터구간 내 계절별 열전달계수는 각각 여 름철 7.68 W/m2·K와 겨울철 7.24 W/m2·K의 수치를 나타냈다.
        4,200원
        105.
        2010.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The numerical analysis by using CFX 11.0 commercial code was done for proper design of the heat exchanger. The present experimental studies were also conducted to investigate the effects of circulating solid particles on the characteristics of fluid flow, heat transfer and cleaning effect in the fluidized bed vertical shell and tube type heat exchanger with counterflow, at which a variety of solid particles such as glass (3 mmΦ), aluminum (2~3 mm Φ), steel (2~2.5 mmΦ), copper (2.5 mmΦ) and sand (2~4 mmΦ) were used in the fluidized bed with a smooth tube. Seven different solid particles have the same volume, and the effects of various parameters such as water flow rates, particle diameter, materials and geometry were investigated. The present experimental and numerical results showed that the flow velocity range for collision of particles to the tube wall was higher with heavier density solid particles, and the increase in heat transfer was in the order of sand, copper, steel, aluminum, and glass. This behavior might be attributed to the parameters such as surface roughness or particle heat capacity.
        4,800원
        106.
        2009.12 구독 인증기관 무료, 개인회원 유료
        This study aims to evaluate the heat transfer characteristics and energy consumption in the wet and dry ondol systems. Conditions of the continued heating mode set the room temperature at 20℃ and hot water supply temperature at 60℃ and 70℃ for 3 days. The scheduled heating mode operates heating at 6~9am (room temperature at 20℃), suspends heating at 9~18pm (leaving mode), and runs heating at 1 8~24am (room temperature at 20℃) and 24~6am (room temperature at 17℃) for 2 days. The results from the continued heating mode in the dry/wet ondol systems confirmed that the dry and wet systems had the same average indoor temperature (18.9℃) and similar energy consumption. In addition, the results from the scheduled heating mode in the dry/wet ondol systems confirmed that the dry ondol system had lower energy consumption than the wet ondol system. Therefore, the scheduled heating mode in the dry ondol system is expected to reduce energy consumption.
        4,000원
        107.
        2009.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        전해제련 공정은 악티늄족 원소를 동시에 회수하는 공정으로써, Pyroprocessing의 핵확산 저항성을 보장 하는 중요한 공정이다. 공학규모의 전해제련 장치를 설계하기 위한 기본 도구를 개발하기 위해서 실험실 규 모의 장치에 대한 열전달 해석을 수행하였다. 열전달 해석을 수치 해석적으로 계산하기 위해 ANSYS CXF 상 용 코드를 사용하였다. 열전달 해석 결과, 가열부의 길이가 수직으로 용융염의 높이보다 약 3배 이상이 되었 을 때, 용융염의 온도를 일정하게 유지할 수 있었으며, 냉각부의 길이는 그 영향이 미비하였다. 전해조 덮개아래의 아르곤 가스의 온도는 냉각 판의 개수에 따라 감소하였으며, 5개 이상 설치 할 경우 250 ℃ 이하로 유 지할 수 있음을 보였다. 이러한 계산 결과는 실제 실험 장치에서 측정된 장치 내부 온도 분포와 경향성이 일 치하는 것을 볼 수 있었다. 본 연구에서 해석된 전해제련 장치의 열 분포 특성은 공학규모 장치의 설계를 위 해 중요한 자료로 사용 될 수 있을 것이다.
        4,000원
        108.
        2009.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The researcher inquired drying characteristics by reflecter shape. Near infrared ray (NIR) is very useful in various drying field. The researcher compared and investigated, temperature about reflecter's shape with numerical analysis method and experimental method. The researcher also investigated about distance between a lamp and a drying target plate using experimental method. As far as a experimental method is concerned, the researcher used the thermal image processing system for changing distance between a lamp and a drying target plate into H=500mm, 600mm and 700mm. Also presented experimental results are compared about thermal image for temperature distribution at each cases. As a result, the researcher has come to the H=700mm about best result in this study.
        4,000원
        109.
        2009.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The paper reports on the prediction of turbulent heat transfer in flows between parallel plates with wall transpiration. The elliptic blending second moment closure for turbulent stresses and the GGDH model for turbulent heat fluxes are employed to predict the turbulent flow and heat transfer. The numerical results by the adopted models are directly compared to the DNS data and the measurements to assess the performance of the model predictions. The predictions show correctly the effect of deceleration and acceleration of the flow caused by the transpiration, and the anisotropy of the turbulence structure is augmented towards downstream by the fluid injection. The turbulence structure and heat transfer characteristics of transpired flows are well captured by the present turbulence and heat flux models.
        4,000원
        110.
        2009.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study is experimentally to analyze the heat transfer characteristics and photographic observation of bubble generation in saturated nucleate pool boiling. The photographs were taken of water boiling from heated nickel wires. The attempts is made to explain the different nucleate boiling of water. Some of the bubbles photographed were very close to the spherical shape, while others were close to the hemispherical. Also, a number of bubble had intermediate shapes that were called oblate bubbles. At least, heat transfer regions of three and possibly four were found to exist in nucleate boiling depended upon the mode of vapor generation. The vapor structure on the surface progressed through a sequence of first discrete bubbles, then vapor columns and vapor mushrooms, and finally vapor paths, as the surface temperature was increased. These individual vapor structures or combinations of them determine the mechanism of heat transfer in the four nucleate boiling regions.
        4,000원
        111.
        2007.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 계면경계에서 특이성을 갖는 이종재료 열전달문제를 효율적으로 해석할 수 있는 이동최소제곱 유한차분법을 제시한다 이동최소제곱 유한차분법은 격자망(grid)없이 절점만으로 이동최소제곱법을 이용하여 Taylor 다항식을 구성하고 차분식을 만들어 미분방정식을 직접 푼다. 초평면함수 개념에 근거한 쐐기함수를 이동최소제곱 센스(sense)로 근사식에 매입하여 쐐기거동과 미분 점프에 따른 계면경계 특성을 효과적으로 묘사하고 고속으로 미분을 근사하는 이동최소제곱 유한차분법의 강점을 발휘하도록 했다. 서로 다른 열전달계수를 갖는 이종재료 열전도문제 해석을 통해 이동최소제곱 유한차분법이 계면경계문제에서도 뛰어난 계산효율성과 해의 정확성을 확보할 수 있음을 보였다.
        4,000원