검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 121

        21.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Background: The CKCUES test evaluates the functional performance of the shoulder joint. The CKCUES test scores CKC exercises of the upper limbs to examine shoulder stability. Although the CKCUES test provides quantitative data on functional ability and performance, no study has determined the relationship between CKCUES scores and SA and TB muscle strength. Objects: The objective of this study is to determine the relationship between the CKCUES test scores and the strength of the SA and TB muscles in the CKCUES and unilateral CKCUES tests. Methods: Sixty-six healthy male volunteers participated in the study. A Smart KEMA strength sensor measured SA and TB muscle strength. Two parallel lines on the floor indicated the initial hand placement to start CKCUES tests. For 15 seconds, the subject raises one hand and reaches over to touch the supporting hand, then returns to the starting position. Results: The correlation between the CKCUES test scores and the strength of the SA was strong (r = 0.650, p < 0.001), and the TB was moderate (r = 0.438, p < 0.001). The correlation between the unilateral CKCUES test and the strength of the SA of the supporting side was strong (r = 0.605, p < 0.001), and swing side was strong (r = 0.681, p < 0.001). The correlation between the unilateral CKCUES test and the strength of the TB of the supporting side was moderate (r = 0.409, p < 0.001), and swing side was moderate (r = 0.482, p < 0.001). Conclusion: Our study showed that the CKCUES test had a strong association with isometric strength of SA and moderate association with that of TB. These findings suggest that the CKCUES test can evaluate the function of the SA. Moreover, the unilateral CKCUES test can evaluate unilateral shoulder function.
        4,000원
        22.
        2021.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study examined the effect of ultraviolet (UV) application on bacterial disinfection in a commercialized humidifier using ultrasonic wave (UW). To accurately examine disinfection kinetics in tap-water condition, tap-water was sterilized using a filter, and then inoculated with pure cultures of E. coli and P. putida with known viable counts. The disinfection kinetic characteristics were experimentally compared when UV alone, UW alone, and UW+UV together were applied in disinfecting the added bacteria in the commercialized humidifier. When UV alone was applied, bacterial disinfection kinetics followed a first-order decay reaction, and showed an approximately 10-time weaker disinfection compared to the typical UV disinfection in water treatment or wastewater treatment. When UW alone was applied, bacterial disinfection kinetics followed a second-order decay reaction with a low disinfection rate constant of 0.0002 min-1(CFU/mL)-1. When UV and UW were applied together, however and interestingly, the disinfection rate constant (0.0211 min-1(CFU/mL)-1) was approximately 100 times increased than that for the UW alone case. These results revealed that the co-use of UV and UW can provide synergistic effect on bacterial disinfection in a tap-water condition in household humidifiers.
        4,000원
        23.
        2021.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        High voltage impulse (HVI) has been gained attention as an alternative technique that could control the CaCO3 scale problems encountered in water main, pipe, cooling tower and heat exchanger vessels. The aim of this study was to investigate the effect of electric field (E) and contact time (t) of HVI on reduction of Ca2+ concentration at two different temperatures of 25℃ and 60℃. A kinetic model on the effect of E and t was investigated too. As the E and t increased, the Ca2+ concentration decreased more than that of the control (= no HVI). The Ca2+ concentration decreased up to 81% at 15 kV/cm at 60℃, which was nearly 2 times greater than the control. With these experimental data-set of reduction of Ca2+ concentration under different E and t, the kinetic model was developed. The relationship between E and t required to reduce the concentration of Ca2+ by 30% was modeled at each temperature. The empirical model equations were; E0.83· t = 60.3 at 25℃ and E0.08· t = 1.1 at 60℃. These equations state the products of En and t is always constant, which means that the required contact time can be reduced in accordance with the increment of E and vice versa.
        4,000원
        24.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Background: Repetitive damage to the ankle joint causes chronic ankle instability, and studies comparing the effects of exercise in open and closed chains as a treatment method are very rare. Objectives: To investigate the effects of open and closed kinetic exercises on muscle activity and dynamic balance of ankle joint in adults with chronic ankle instability. Design: Single-blind randomized controlled trial. Methods: The selected 30 subjects are randomly divided into open kinetic chain exercise experimental group (EGⅠ, n=10), closed kinetic chain exercise experimental group (EGⅡ, n=10), and stretching control group (CG, n=10). Open and closed kinetic exercises lasted 30 minutes three times a week for six weeks and stretching exercises performed four actions for 20 seconds and five sets. The measurement tools using surface electromyography to measure muscle activity in the ankle joint. The dynamic balance of the ankle was evaluated using the Y-Balance test. Results: Following the intervention, closed and open kinetic chain exercise group showed significant difference in tibialis anterior and gastrocnemius muscle activity and dynamic balance (P<.05). However, no significant difference in tibialis anterior and gastrocnemius muscle activity and dynamic balance between closed and open kinetic chain exercise group (P<.05). Conclusion: This study provides evidence that closed and open kinetic chain exercise can be presented as an effective exercise for the muscle activity of ankle muscle and dynamic balance of the subject with chronic ankle instability.
        4,000원
        25.
        2020.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Background: The hip muscle plays various roles. Several types of functional performance tests are used for the assessment of patients with various lower extremity injuries. Hip muscle functions are important to test the performance of maintaining the spine, pelvic, and leg during bridging exercise. We designed a novel functional performance test tool, which we named close kinetic chain dynamic lower extremity stability (CKCLE) test to assess hip muscle functions. Objects: The purpose of this study was to determine the relationship between CKCLE test and hip extensor, external rotator, and abductor strengths. Methods: Twenty-two subjects were recruited in the present study (13 males and 9 females). The hip extensor, external rotator, and abductor muscle strengths were measured using a Smart KEMA strength sensor. When the examiner said “Go”, the subject performed the CKCLE test by moving one leg from the floor and touching the opposite knee and then return to the floor while maintaining the bridging position. The subjects attempted as many “touches” as possible in the allotted time (20 seconds) during the maximal tests. The correlation between the hip muscle (extensor, external rotator, and abductor) strength of the supporting leg and the number of CKCLE tests performed in 20 seconds was determined using the Pearson correlation. Results: Hip extensor (r = 0.626, p < 0.05), hip external rotator (r = 0.616, p < 0.05), and hip abductor muscle strengths (r = 0.475, p < 0.05) positively correlated with the number of CKCLE tests performed. Conclusion: We designed a CKCLE test and found that performance in the test correlated with hip extensor, external rotator, and abductor muscle strengths. The result suggests that the CKCLE test can be applied as a performance test to assess the functions of the hip extensor, external rotator, and hip abductor muscles.
        4,000원
        26.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 딥 스쿼트 동작 시 발목 관절 유연성이 무릎 관절의 운동역학적 요인들간의 관련성을 분석하는데 있었다. 본 연구는 최근 1년간 하지 근골격계 병력이 없는 성인 남성 19명과 여성 8명이 연구대상자로 참여하였다. 딥 스쿼드 시 발목 관절 유연성과 하지 관절의 운동역학적 요인들과 상관관계를 검증하기 위해 pearson의 적률상관계수(pearson’s correlation coefficient)를 이용하였고(SPSS 24.0, Armonk, NY, USA), 통계적으로 유의미한 상관성을 나타낸 변인들은 단순회기분석(simple regression analysis)을 실시하였으며, 유의 수준은 .05로 설정하였다. 본 연구를 통해 발목 관절 유연성과 무릎 관절의 압력을 결정하는 최대 관절모멘트와 관절반발력 요인들 간의 관련성을 확인할 수 있었다. 그러므로 근력 트레이닝 시 딥 스쿼트와 같은 무릎 관절에 많은 부하를 발생시킬 수 있는 운동을 적용할 때 개인에 신체적 특성 중 발목 관절의 유연성의 정도를 확인하는 것은 신체의 안정성과 무릎 관절의 상해 위험성을 감소시킬 수 있는 운동 강도를 설정하는데 도움이 될 수 있을 것으로 기대한다.
        4,000원
        27.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Although membrane bio-reactor (MBR) has been widely applied for wastewater treatment plants, the membrane fouling problems are still considered as an obstacle to overcome. Thus, many studies and commercial developments on mitigating membrane fouling in MBR have been carried out. Recently, high voltage impulse (HVI) has gained attention for a possible alternative technique for desalting, non-thermal sterilization, bromate-free disinfection and mitigation of membrane fouling. In this study, it was verified if the HVI could be used for mitigation of membrane fouling, particularly the internal pore fouling in MBR. The HVI was applied to the fouled membrane under different conditions of electric fields (E) and contact time (t) of HVI in order to investigate how much of internal pore fouling was reduced. The internal pore fouling resistance (Rf) after HVI induction was reduced as both E and t increased. For example, Rf decreased by 19% when the applied E was 5 kV/cm and t was 80 min. However, the Rf decreased by 71% as the E increased to 15 kV/cm under the same contact time. The correlation between E and t that needed for 20% of Rf reduction was modeled based on kinetics. The model equation, E1.54t = 1.2 × 103 was obtained by the membrane filtration data that were obtained with and without HVI induction. The equation states the products of En and t is always constant, which means that the required contact time can be reduced in accordance with the increase of E.
        4,000원
        28.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The impact of storage temperature on the changes in acid value(AV), peroxide value(POV), color value, total phenolic content(TPC), and antioxidant activity in perilla seed(PS) was investigated. The PS was stored at 25, 35, and 45℃ for four weeks. An increase in the storage temperature resulted in significantly increased AV, POV, redness, and yellowness of the PS. Conversely, TPC, antioxidant activity, and redness of the PS significantly decreased. The changes in the AV and POV followed a first-order kinetic model, and the kinetic parameters such as k, t1/2, Q10 and Ea were calculated. The k and t1/2 values decreased with increasing storage temperature and the Q10 values for the AV and POV were 1.56, 1.91, 4.61, and 3.43, respectively. The Ea for the changes in of the AV and POV in the PS were 70.40, 102.63 kJ/mol, respectively. The half-life values for the AV and POV of the PS at 25℃ were 169.52 and 373.18 days, respectively, while the values at 45℃ for those, were 28.47 and 27.93 days, respectively.
        4,000원
        30.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Batch adsorption tests were performed to evaluate the applicability of adsorption kinetic model by using hydrogel chitosan bead crosslinked with glutaraldehyde (HCB-G) for Cu(II) as cation and/or phosphate as anion. Pseudo first and second order model were applied to determine the sorption kinetic property and intraparticle and Boyd equation were used to predict the diffusion of Cu(II) and phosphate at pore and boundary-layer, respectively. According to the value of theoretical and experimental uptake of Cu(II) and phosphate, pseudo second order is more suitable. On comparison with the value of adsorption rate constant (k), phosphate kinetic was 2-4 times faster than that of Cu(II) at any experimental condition indicating the electrostatic interaction between NH3 + and phosphate is dominated at the presence of single component. However, when Cu(II) and phosphate simultaneously exist, the value of k for phosphate was sharply decreased and then the difference was not significant. Both diffusion models confirmed that the sorption rate was controlled by film mass transfer at the beginning time (t < 3 hr) and pore diffusion at next time section (t > 6 hr).
        4,000원
        31.
        2019.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Background: After stroke, in order to improve gait function, it is necessary to increase the muscle strength and to enhance the propriocetive function of the lower extremity. Objects: This study aimed to compare the effects of open kinetic chain (OKC) versus closed kinetic chain (CKC) isokinetic exercise of the hemiparetic knee using the isokinetic equipment on lower extremity sensorimotor function and gait ability in patients with chronic stroke. Methods: Thirty participants with chronic hemiplegia (> 6 months post-stroke) were randomly divided into 2 equal groups: CKC group and OKC group. Patients from both groups attended conventional physiotherapy sessions 3 times a week for 6 weeks. Additionally, subjects from the CKC group performed isokinetic exercise using the CKC attachment, while those from the OKC group performed isokinetic exercise using the OKC attachment. The isokinetic knee and ankle muscles strength, position sense of the knee joint, and spatiotemporal gait parameters were measured before and after interventions. Results: The knee muscles peak torque/body weight (PT/BW) and hamstring/quadriceps (H/Q) ratio significantly increased in both groups (p<.01). In particular, ankle plantarflexors PT/BW, position sense of the knee, gait velocity, and spatial gait symmetry significantly improved in the CKC group (p<.01, p<.05, p<.01, and p<.01, respectively). Conclusion: CKC isokinetic exercise can be an effective therapeutic intervention for the improvement of sensorimotor function of the lower extremity and gait functions, such as gait velocity and symmetry. CKC position in isokinetic strength training is effective to improve functional ability in patients with chronic stroke.
        4,300원
        32.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study examined the influence of operating parameters on the electrosorptive recovery system of lithium ions from aqueous solutions using a spinel-type lithium manganese oxide adsorbent electrode and investigated the electrosorption kinetics and isotherms. The results revealed that the electrosorption data of lithium ions from the lithium containing aqueous solution were well-fitted to the Langmuir isotherm at electrical potentials lower than –0.4 V and to the Freundlich isotherm at electrical potentials higher than –0.4 V. This result may due to the formation of a thicker electrical double layer on the surface of the electrode at higher electrical potentials. The results showed that the electrosorption reached equilibrium within 200 min under an electrical potential of –1.0 V, and the pseudo-second-order kinetic model was correlated with the experimental data. Moreover, the adsorption of lithium ions was dependent on pH and temperature, and the results indicate that higher pH values and lower temperatures are more suitable for the electrosorptive adsorption of lithium ions from aqueous solutions. Thermodynamic results showed that the calculated activation energy of 22.61 kJ mol–1 during the electrosorption of lithium ions onto the adsorbent electrode was primarily controlled by a physical adsorption process. The recovery of adsorbed lithium ions from the adsorbent electrode reached the desorption equilibrium within 200 min under reverse electrical potential of 3.5 V.
        4,000원
        33.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The effects of intake system on turbulent kinetic energy for the in-cylinder flow of a four-valve SI engine were studied. For this study, the same head, cylinder, and the piston were used to examine turbulence characteristics in two different intake systems. In-cylinder flow measurements were conducted using three dimensional LDV system. The measurement method, which simultaneously collects 3-D velocity data, allowed a evaluation of turbulent kinetic energy inside a cylinder. High levels of turbulent kinetic energy were found in regions of high shear flow, attributed to the collisions of intake flows. These specific results support the more general conclusion that the slightly offset direction of the intake system produced higher in-cylinder velocities on the +x-axis side of the cylinder which caused some asymmetric flow patterns about the z-axis. Higher levels of turbulent kinetic energy prevailed in zones of mean velocity collisions and regions where significant directional changes in the mean velocity patterns occurred.
        4,000원
        34.
        2017.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To automate cooking processes, quantitative descriptions are needed on how quality parameters, such as texture change during heating. Understanding mechanical property changes in foods during thermal treatment due to changes in chemical composition or physical structure is important in the context of engineering models and in precise control of quality in general. Texture degradation of food materials has been studied widely and softening kinetic parameters have been reported in many studies. For a better understanding of kinetic parameters, applied kinetic models were investigated, then rate constants at 100°C and activation energy from previous kinetic studies were compared. The food materials are hardly classified into similar softening kinetics. The range of parameters is wide regardless of food types due to the complexity of food material, different testing methods, sample size, and geometry. Kinetic parameters are essential for optimal process design. For broad and reliable applications, kinetic parameters should be generated by a more consistent manner so that those of foods could be compared or grouped.
        4,000원
        35.
        2017.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Background: Methods for exercising serratus anterior (SA) and upper trapezius (UT) muscles are important for the recovery of patients with various shoulder disorders, yet the efficacy of closed or open kinetic chain exercises have not yet been evaluated. Objects: The purpose of this study was to compare the activation of the SA and UT muscles during scapular protraction considering both closed and open kinetic chain exercises. Methods: Thirty subjects were randomly divided into experimental groups (closed kinetic chain exercise) and control groups (open kinetic chain exercise) in which scapular protraction was performed at 90° or 125° shoulder flexion. Electromyographic activity data were collected from the SA and UT muscles per position and exercise method. Results: Separate mixed 2-way analysis of variance showed significant differences in the activation of the SA (F1,28=6.447, p=.017) and the UT (F1,28=35.450, p=.001) muscles between the groups at 90° and 125° shoulder flexion. Also, the SA/UT ratio measures at 90° and 125° shoulder flexion significantly differed between the groups (F1,28=15.457, p=.001). That is, the closed chain exercise was more effective than open chain exercise for strengthening the SA muscle and controlling the UT muscle, 125° of shoulder joint was more effective than 90°. Conclusion: The findings suggest that scapular protraction with shoulder 125° flexion at the closed kinetic chain exercise may be more effective in increasing SA muscle activation and decreasing UT muscle activation as well as increasing the SA/UT ratio than open kinetic chain exercise.
        4,000원
        37.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently EC-MBR (Elctrocoagulation - Membrane Bio Reactor) has been suggested as one of alternative processes to overcome membrane fouling problems. Most important operational parameters in the EC-MBR are known to current density and contact time. Their effect on membrane filtration performances has been reported well, however, quantitative interrelationship between both parameters not been investigated yet. The purpose of this study is to give a kinetic model suggesting the current density and the contact time required to reduce the membrane fouling. The 4 different set of current densities (2.5, 6, 12 and 24 A/m2) and contact times (0, 2, 6 and 12 hr) were selected as operational parameters. After each electro-coagulation under the 16 different conditions, a series of membrane filtration was carried out. The membrane fouling decreased as the current density and contact time increased, Total fouling resistances under different conditions, Rt(=Rc+Rf) were calculated and compared to those of the controls (R0), which were calculated from the data of experiments without electro-coagulation. A kinetic approach for the fouling reduction rate (Rt / R0) was carried out and the equation ρi0.46t=7.0 was obtained, which means that the product of current density and the contact time needed to reduce the fouling in certain amounts (in this study, 10% of fouling reduction) is always constant.
        4,000원
        40.
        2017.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Carboxylated multi-wall carbon nanotubes (MWCNTs-COOH) have been used as efficient adsorbents for the removal of picric acid from aqueous solutions under stirring and ultrasound conditions. Batch experiments were conducted to study the influence of the different parameters such as pH, amount of adsorbents, contact time and concentration of picric acid on the adsorption process. The kinetic data were fitted with pseudo-first order, pseudo-secondorder, Elovich and intra-particle diffusion models. The kinetic studies were well described by the pseudo-second-order kinetic model for both methods. In addition, the adsorption isotherms of picric acid from aqueous solutions on the MWCNTs were investigated using six two-parameter models (Langmuir, Freundlich, Tempkin, Halsey, Harkins-Jura, Fowler- Guggenheim), four three-parameter models (Redlich-Peterson, Khan, Radke-Prausnitz, and Toth), two four-parameter equations (Fritz-Schlunder and Baudu) and one five-parameter equation (Fritz-Schlunder). Three error analysis methods, correlation coefficient, chi-square test and average relative errors, were applied to determine the best fit isotherm. The error analysis showed that the models with more than two parameters better described the picric acid sorption data compared to the two-parameter models. In particular, the Baudu equation provided the best model for the picric acid sorption data for both methods.
        4,200원
        1 2 3 4 5