검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 16

        1.
        2019.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The tendency to use a probabilistic design method rather than a deterministic design method for the design of nuclear power plants (NPPs) will increase because their safety should be considered and strictly controlled in relation to various causes of damage. The distance between a seismically isolated NPP structure and a moat wall is called the clearance to stop. The clearance to stop is obtained from the 90th percentile displacement response of a seismically isolated NPP subject to a beyond design basis earthquake (BDBE) in the probabilistic design method. The purpose of this study is to analyze the effects of heating and buckling effects on the 90th percentile displacement response of a lead-rubber bearing (LRB) subject to a BDBE. The analysis results show that considering the heating and buckling effects to estimate the clearance to stop is conservative in the evaluation of the 90th percentile displacement response. If these two effects are not taken into account in the calculation of the clearance to stop, the underestimation of the clearance to stop causes unexpected damage because of an increase in the collision probability between the moat wall and the seismically isolated NPP.
        4,200원
        2.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The seismically isolated nuclear power plants shall be designed for design basis earthquake (DBE) and considered to ensure safety against beyond design basis earthquake (BDBE). In order to limit the excessive displacement of the seismic isolation system of the seismically isolated structure, the moat is installed at a certain distance from the upper mat supporting the superstructure. This certain distance is called clearance to stop (CS) and is calculated from the 90th percentile displacement of seismic isolation system subjected to BDBE. For design purposes, the CS can be obtained simply by multiplying the median displacement of the seismic isolation system against DBE by scale factor with a value of 3. The DBE and BDBE used in this study were generated by using 30 sets of artificial earthquakes corresponding to the nuclear standard design spectrum. In addition, latin hyper cube sampling was applied to generate 30 sets of artificial earthquakes corresponding to maximum - minimum spectra. For the DBE, the median displacement and the 99th percentile displacement of the seismic isolation system were calculated. For the BDBE, the suitability of the scale factor was assessed after calculating the 90th percentile displacement of the seismic isolation system.
        4,000원
        3.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to modeling seismic isolation system such as lead-rubber bearing (LRB), bilinear model is widely used by many researchers. In general, an actual force-displacement relationship for LRB has a smooth hysteretic shape. So, Bouc-Wen model with smooth hysteretic shape represents more accurately actual hysteretic shape than bilinear model. In this study, seismic responses for seismically isolated nuclear power plant (NPP) with LRB modelled by Bouc-Wen and bilinear models are compared with those of NPP without seismic isolation system. To evaluate effect of earthquake characteristics for seismic responses of NPP isolated by LRB, 5 different site class earthquakes distinguished by Geomatrix 3rd Letter Site Classification and artificially generated earthquakes corresponding to standard design spectrum by Reg. Guide 1.60 are used as input earthquakes. From the seismic response results of seismically isolated NPP, it can be observed that maximum displacements of seismic isolation modelled by Bouc-Wen model are larger than those by bilinear model. Seismic responses of NPP with LRB is significantly reduced than those without LRB. This reduction effect for seismic responses of NPP subjected to Site A (rock) earthquakes is larger than that to Site E (soft soil) earthquakes.
        4,000원
        4.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, many people have become interested in seismic stability enhancement and a chain of research and development be proceed for application of nuclear power plant according to increase the frequency and magnitude of earthquake event. Such as seismic isolation system is applied to general structure (architecture, bridge and LNG tank etc.) from ancient times. But the application results is limited for Nuclear power plant. In this paper, we proposed a stability of variable axial load from beyond design basis earthquake in Nuclear power plant. Also, the change of stiffness in isolator from the application of generally design equation is not equal to according to change in axial load compare with the experimental result in variable axial load. Therefore we proposed the empirical formula of design equation from test result of full-scale multi-lead rubber bearing for seismic analysis with real behavior (variable axial load) in the earthquake motion.
        4,000원
        5.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The lead-rubber bearing (LRB) dissipates seismic energy through plastic deformation of lead core. Under large-displacement cyclic motion, the temperature increases in the lead core. The shear strength of a lead–rubber bearing is reduced due to the heating effect of the lead core. In this study, the seismic responses such as displacement increasing, shear strength and vertical stiffness degradations of LRB due to the heating effect are evaluated for design basis earthquake (DBE) and beyond design basis earthquake (150% DBE, 167% DBE, 200% DBE).
        4,000원
        6.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to increase seismic performance of nuclear power plant (NPP) in strong seismic zone, lead-rubber bearing (LRB) can be applied to seismic isolation system of NPP structures. Simple equivalent linear model as structural analysis model of LRB is more widely used in initial design process of LRB than a bilinear model. Seismic responses for seismically isolated NPP containment structures subjected to earthquakes categorized into 5 different soil-site classes are calculated by both of the equivalent linear- and bilinear- LRB models and compared each others. It can be observed that the maximum displacements of LRB and shear forces of containment in the case of the equivalent linear LRB model are larger than those in the case of bilinear LRB model. From the seismic fragility curves of NPP containment structures isolated by LRB, it can be observed that seismic fragility in the case of equivalent linear LRB model are about 5~30 % larger than those in the case of bilinear LRB model.
        4,200원
        7.
        2015.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to perform a soil-isolation-structure interaction analysis of seismically isolated nuclear power plant (NPP) structures, the nonlinear behavior of a seismic isolation system may be converted to an equivalent linear model used in frequency domain analysis. Seismic responses for seismically isolated NPP containment structures subjected to a simple artificial acceleration history and different site class earthquakes are evaluated for the equivalent-linear and nonlinear models that have been applied to lead-rubber bearing (LRB) modeling. It can be observed that the maximum displacements of the equivalent linear model are larger than that of the nonlinear model. From the floor response spectrum analysis for the top of NPP containment structures, it can be observed that the spectral acceleration of an equivalent linear model at about 0.5 Hz frequency is about 2~3 times larger than that of a nonlinear model.
        4,200원
        8.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Rubber laminated bearings with lead core are highly affected by changes in temperature because key materials which are rubber and lead have temperature dependencies. In this study, two full scale LRB(D800, S=5) are manufactured and temperature dependency tests on shear properties are accomplished. The shear properties at the 3rd cycle are used at -10℃, 0℃, 10℃,20℃, 30℃, 40℃ respectively. The double shear configuration, simultaneously testing two pieces, is applied for compression shear test in order to minimize the friction effects due to the test machine, described in ISO 22762-1:2010. Characteristic strength, post-yield stiffness, effective stiffness, equivalent damping ratio are estimated and presented coefficient due to the temperature changes.
        4,000원
        9.
        2002.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 지진하중을 받는 사장교의 진동제어 기법 개발을 위해 제공된 벤치마크 사장교에 복합제어 기법을 적용하였다. 이 벤치마크 문제는 2003년 완공 예정으로 미국 Missouri 주에 건설중인 Cape Girardeau 교를 대상 구조물로 고려하였다. Cape Girardeau 교는 New Madrid 지진구역에 위치하고 Mississippi 강을 횡단하는 주요 교량이라는 점 때문에 설계 단계에서부터 내진 문제를 중요하게 고려하였다. 벤치마크 문제에는 사장교의 상세한 설계도면에 기초해 교량의 복잡한 거동을 나타낼 수 있는 3자원 선형모델과 각 제어기법의 성능을 평가하기 위한 18개의 평가기준이 제시되어 있다. 본 연구에서 적용한 복합제어 기법은 지진하중으로 인해 구조물에 발생되는 하중을 줄이기 위한 수동제어 기법과 상판변위와 같은 구조물의 응답을 추가적으로 제어하기 위한 능동제어 기법이 결합된 제어 방법이다. 수동제어 장지로는 납고무받침을 사용하였고 Bouc-Wen 모델을 사용하여 비선형 거동을 고려 할 수 있도륵 모델링 하였다. 능동제어 장치로는 이상적인 hydraulic actuators 가 사용되었으며 제어 알고리듬은 H_2/LQG 를 적용하였다. 수치해석 결과 제안방법의 성능은 수동제어 방법에 비해 매우 효과적이며, 능동제어 방법에 비해서는 약간 좋은 제어성능을 나타내었다. 복합제어 방법은 수동제어 부분 때문에 능동제어 방법에 비해 보다 신뢰할 수 있는 제어 방법이다. 따라서 제안된 제어방법은 지진하중을 받는 사장교의 제어를 위해 효과적으로 사용될 수 있다.
        4,500원
        11.
        2001.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 수평전단시험을 통하여 LRB(lead-rubber hearing)의 동적 특성을 분석하였다. 10ton 및 200ton 용량의 LRB를 이용하여 수평전단시험을 수행한 결과 LRB의 동적 특성은 수평하중의 재하속도, 연직하중의 크기 및 전단변형률 등에 따라 크게 달라지는 것으로 나타났다. 세장비가 큰 면진장치에 과도한 변형을 가할 경우 내부 납심에 소성한지가 발생되어 납심이 파괴되는 것으로 나타났다. 따라서 면진구조물의 설계 및 해석 시에는 지진응답과 재하하중의 크기에 따라서 달라지는 LRB의 기계적 특성치를 적용하여 안전한 설계가 이루어질 수 있도록 하여야 한다.
        4,000원
        12.
        1998.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        구조물의 내진 성능 향상을 위해 현재 종종 사용되어지고 있는 기초분리장치인 적층고베어링과 납-고무 베어링의 내진성능을 실험적으로 파악하였다 베어링의 전단 변형률 또는 가해진 수직 하중이 클수록 베어링의 전단 강성은 감소하며 가력 속도에 대한 영향을 무시할 만하다. 베어링은 순수압축력에는 강하며 인장력에는 그 반대이다.
        4,000원
        13.
        2017.04 서비스 종료(열람 제한)
        The magnitude of the earthquake in the world has increased recently, and the interest in the seismic performance of the structures and major facilities has increased after the Gyeongju earthquake(2016.09). In this study, it secured the seismic performance of the tank to store oil, LPG and water etc. by applying Lead Rubber Bearing and performed shaking table test to verify.
        14.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        The magnitude of the earthquake in the world has increased recently, and the interest in the seismic performance of the structures and major facilities has increased after the Gyeongju earthquake(2016.09). In this study, it secured the seismic performance of the tank to store oil, LPG and water etc. by applying Lead Rubber Bearing and performed shaking table test to verify.
        15.
        2014.10 서비스 종료(열람 제한)
        Has been widely applied in order to minimize damage such as earthquake engineering and building structures, because the economics and efficiency is relatively good seismic isolators. Are widely used from the seismic isolation bearings LRB inhibits excessive displacement occurs on foot by improving the damping capacity of the seismic isolation structure with the flexibility of the rubber bearings during the earthquake, and secure the safety by reducing the seismic forces. The flexible backing is required unlike the conventional one for civil engineering, considering the characteristics of the seismic isolation building plate is the upper structure. The aim of this study was to perform a compression and shear tests to validate the performance limits of the performance of seismic isolation bearings supporting the main features of the structure and lateral displacement.
        16.
        2009.05 KCI 등재 서비스 종료(열람 제한)
        지진으로부터 구조물의 안전을 확보하기 위하여 많은 공학자들의 연구가 계속되고 있다. 본 연구에서는 납의 이력특성을 이용하여 지진하중을 감소시키는 LRB(lead rubber bearing)의 감쇠능력에 대한 실험적 연구를 수행하였다. 납 플러그의 면적비를 주요변수로 설계한 2종류 12개의 시험체를 제작하여 변위제어시험을 시행하였다. 감쇠비 결정을 위한 이력감쇠곡선을 얻기 위하여 2개의 시험체가 한 쌍을 이루도록 배치하고 3회 반복이력시험을 수행하였다. 실험결과로부터 본 연구에서의 납 플러그 면적비가 큰 LRB는 지진시 구조물의 지진하중을 감소시키는데 충분한 감쇠비를 보유하고 있음을 알 수 있었다.