검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 110

        1.
        2024.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aimed to investigate the language usage of outdoor advertisements and find ways to improve it from the perspective of public language. Anyone is exposed to signboards without limitations, and it allows the public to learn fixed language forms for a long time. Therefore, it has both direct and indirect effects on the public’s language lives. This study focuses on sign language as a public language. Here, signboards from four districts in Gyeonggi-do were collected and analyzed in three ways. Signboards marked only in Korean accounted for a relatively large proportion of the main words, whereas mixed types of characters were used together in the subwords. In addition, there were cases of intentional violation of the language norm and listed only the initial consonants, those conscious of ambiguity. Results show that follow-up studies, such as conducting an additional survey, designating a demonstration area for the practical maintenance of sign language, and preparing guidelines for the production of outdoor advertisements, are expected to continue.
        7,800원
        2.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        과거 감시와 통제, 박탈의 역할을 담당했던 교정시절은 보안성에 중점을 두어 설계되었다. 책임형벌주 의에 따른 자유박탈처분은 불가결한 것이지만 현대의 행형이념이 재소자의 재사회에 있다는 점, 구금 으로 인해 발생하는 재소자들의 정신, 심리적 문제 등이 적지 않다는 점 등으로 교정시설의 처우개선을 위한 논의가 진행되고 있다. 이에 본 연구는 교정시설 공간에서의 일상성 회복과 치유를 통한 재소자의 재사회화와 회복적 개념의 교정시설 설계를 제안하였다. 대상지에 대한 일성상 회복의 개념을 적용한 외부공간 설계의 구체적인 설계 전략은 다음과 같다. 첫째, 회복과 치유를 위한 6가지의 원칙을 적용하 였다. 물리적으로 안전하고 사고의 위험 요소가 없는 환경, 긍정적 교류의 장으로서의 환경, 차분한 분 위기의 환경, 이동과 선택의 자유가 보장되는 환경, 일상적 환경과 닮은 공간, 교정시설의 느낌이 사라 진 환경 등이다. 둘째, 연결에 중점을 둔 동선 체계화로 재소자와 자연환경의 상호작용을 촉진하였다. 셋째, 절화정원 조성을 통한 외부 사회와의 소통, 인간적인 연결, 일상성 회복과 치유의 조화를 모색하 였다. 본 연구는 교정시설에 대한 일상성 회복 개념의 적용 논의를 확장하고 앞으로 회복적 개념의 교정 시설 설계를 위한 참고 자료를 제공하는데 학술적 의의가 있다.
        4,000원
        4.
        2023.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The use of hanging scaffolding for exterior wall painting and cleaning in building construction and maintenance carries the inherent risk of fall accidents. While periodic rope replacement is crucial for preventing accidents resulting from rope breakage, current regulations lack specificity in determining appropriate disposal period for fiber ropes. This study analyzed the tensile strength of the most commonly used PP fiber ropes with different diameters (16 mm, 20 mm) in the domestic construction industry. Additionally, the effect of outdoor exposure was examined by measuring the tensile strength of new ropes and ropes exposing to outdoor conditions for 30 days and 90 days. The results showed that the new ropes and those exposed to outdoor for 30 days met the KS (Korean Standards) criteria for tensile strength. However, a significant decrease in tensile strength was observed in ropes exposed to outdoor for 90 days compared to both the new ropes and those exposed for 30 days. Furthermore, the ropes exposed for 90 days did not meet the KS criteria. These findings indicate the degradation of PP fiber ropes due to UV (Ultra Violet) radiation, highlighting the importance of considering this factor when determining the replacement period for fiber ropes used in scaffolding work.
        4,000원
        5.
        2023.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to analyze research trends regarding outdoor wear. For this purpose, the data-collection period was limited to January 2002–October 2022, and the collection consisted of titles of papers, academic names, abstracts, and publication years from the Research Information Sharing Service (RISS). Frequency analysis was conducted on 227 papers in total to check academic journals and annual trends, and LDA topic-modeling analysis was conducted using 20,964 tokens. Data pre-processing was performed prior to topic-modeling analysis; after that, topic-modeling analysis, core topic derivation, and visualization were performed using a Python algorithm. A total of eight topics were obtained from the comprehensive analysis: experiential marketing and lifestyle, property and evaluation of outdoor wear, design and patterns of outdoor wear, outdoor-wear purchase behavior, color, designs and materials of outdoor wear, promotional strategies for outdoor wear, purchase intention and satisfaction depending on the brand image of outdoor wear, differences in outdoor wear preferences by consumer group. The results of topic-modeling analysis revealed that the topic, which includes a study on the design and material of outdoor wear and the pattern of jackets related to the overall shape, was the highest at 30.9% of the total topics. The next highest topic was also the design and color of outdoor wear, indicating that design-related research was the main research topic in outdoor wear research. It is hoped that analyzing outdoor wear research will help comprehend the research conducted thus far and reveal future directions.
        5,100원
        6.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Although monitoring of radon has been extensively implemented throughout South Korea, the risk assessment has been mainly limited to indoor environments such as schools, workplaces, and multi-use facilities, and evaluations have normally been performed separately. In this study, the differences in radon exposure according to two groups (< 1 and 1-6 years old) were evaluated considering various indoor and outdoor environments, timeactivity patterns, variations in radon concentrations, and dwelling type (single detached and apartment house) using Monte-Carlo simulation. The distribution and representative values of radon concentration by micro-environments were confirmed through the Anders-Darling test, and a uniform distribution was applied in case of uncertainty. The effective dose ranged from 1.81 ± 1.19 to 2.81 ± 3.02mSv/y. Comparing the levels recommended by EPA, WHO, and ICRP with the value of the 95th percentile of this study, it was found that the results for those dwelling in detached houses exceeded recommended levels. Infants that spend a lot of time in homes with relatively high levels of concentration of radon are assessed to be somewhat more vulnerable to radon exposure.
        4,000원
        7.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A Catholic school is a school that spreads religious ideology to students by combining religious education with regular school curriculum. But, most Catholic schools do not have a separate liturgical space, mass is performed in multipurpose spaces such as auditoriums, and are exposed to severe acoustic defects due to the very aging facilities and lack of sound performance suitable for the liturgical space. So, in this study, an improvement plan was proposed using sound simulation after identifying acoustic defects through field measurements in the liturgical space of Haeseong High School in Jeonju. Also, hearing experiment using Acoustic Psychological Analysis was conducted to identify changes in subjective responses felt by students as they improved their acoustic performance. The results of study, before and after sound performance improvement sound pressure level(SPL500Hz) was 64.8dB at 66.7dB, the weighted sound level(SPLdB(A)) was 67.9dB(A) at 75.8dB(A), reverberation time(RT500Hz) was 2.04sec at 2.52sec, definition(D50,500Hz) was 40.2% at 33.5%, clarity(C80.500Hz) was –0.8dB at –1.18dB, and RASTI was 57.7% at 49.2% was evaluated. In addition, the amount of improvement in subjective responses before and after sound performance through psycho-acoustic experiment decreased by “Reverberation” -17.0%, “Loudness” -11.3% and increased by “Clear” 21.3%, “Vivid” 21.3%, “Intimacy” 12.4%, “Warmth” 14.3%, “Stability” 19.3%, “Godliness” 18.8%. Therefore, after improving sound performance, Haesung High School's liturgical space improved satisfaction with subjective sound performance felt by students and teachers to ensure sound performance suitable for the liturgical space.
        4,800원
        8.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we investigated the Indoor and Outdoor concentrations of PM10 in Y area, Jeollanam-do. We conducted personal exposure concentration estimates, and Exposure and Risk Assessments using the Time-weighted Average Model. The concentration of Indoor PM10 was 49.38 μg/m3 and that of Outdoor PM10 was 48.02 μg/m3, with the Indoor/ Outdoor Ratio value being 1 or more, and it was found that there was an indoor source of pollution. The Indoor/Outdoor Cr ratio value was 1 or more, and the source of Cr was confirmed to be indoor. Based on our analysis, there was a positive correlation between heavy metals Ni, Cr, and Mn (p<0.05). Using the Time-Weighted Average model, we determined the PM10 personal exposure concentration to be 49.36 μg/m3 and confirmed the feasibility of this model in utilizing the PM10 personal exposure concentrations. In this study, the findings are likely to provide useful data that can be used to determine the concentration of indoor pollutants that are not easy to survey. However, to accurately evaluate indoor air quality, more factors need to be considered and evaluated.
        4,000원
        9.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Volatile organic compounds (VOCs) are chemicals to which humans are exposed frequently via various mediums, including vehicle emissions that contain fine dust and heavy metals, use of organic solvent building materials, furniture, and smoking. Exposure to high concentrations of VOCs may result in loss of consciousness, paralysis, convulsions, and, in the most severe cases, death. Therefore, the present study investigated the indoor and outdoor concentrations of total volatile organic compounds (TVOC) and five types of VOCs (benzene, toluene, styrene, m,p-xylene, and o-xylene) in apartments, a representative residential environment accounting for ~55% of the housing in the Seoul metropolitan area. The research was conducted over four seasons from May 2020 to February 2021, and the levels of VOC concentrations were analyzed by classifying them by season, weekday/weekend, and indoor/outdoor locations. The seasonal trend in VOC concentrations showed that TVOC concentration was highest in summer, with values of 1630.93 ± 1184.10 μg/m3 and 1610.36 ± 1363.43 μg/m3 for indoor and outdoor environments, respectively. The seasonal trends of the concentrations of the five types of VOCs showed that concentrations of benzene and toluene were highest in spring, the concentrations of m,p-xylene and o-xylene were highest in summer, and the concentration of styrene was highest in winter, irrespective of spatial characteristics such as indoor/outdoor environments. In all four seasons, the indoor concentrations were higher than the outdoor concentrations. These results reveal the spatial and temporal distribution characteristics of the VOCs and so can serve as useful basic data for managing indoor and outdoor levels of VOCs.
        4,500원
        11.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to investigate the quality characteristics of bread made with 1%, 3%, 5%, and 7% of Bigeumdo Seomcho powder (Spinacia oleracea L.). The pH of dough and bread decreased as the amount of addition increased; 7% indicated the lowest. The moisture level correlated negatively with the powder addition, but the difference was not statistically meaningful (p<0.05). As the amount of addition was increased, the intensity of color increased but the volume decreased. The brightness and redness of the bread decreased as the amount of addition increased. The volume, specific volume, and baking loss rate correlated negatively with the powder addition. Regarding springiness, cohesiveness, and gumminess, the experiment group was higher than the control group and they lowered as the addition amount increased. The brittleness showed positive correlation with the addition amount. Out of the amino acids of bread, glutamic acid showed the highest value as the amount of addition was increased. Overall, it is possible to produce bakery bread using functional ingredients.
        4,000원
        13.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, we conducted a survey to reveal the general perception of parents toward outdoor air quality, particulate matter (PM), and indoor air quality (IAQ) at schools where their children attend. A total of 1,030 parents participated in this survey, where the age of their children ranged between 7 years to over 19 years of age. Each participant was either a member of a non-governmental organization (NGO) with a keen interest in air quality or an ordinary public panel member with less interest. The result of the survey indicated that the participants had a negative perception of air quality, and parents believed that the outdoor and indoor air is extremely polluted. The participants pointed out that they believe that the main reason for the pollution is due to particulate matter (PM) and school classrooms are the location where their children are exposed to PM the most. Based on our study, the majority of the participants prefer a mechanical ventilation system to reduce indoor air pollutants in schools. Our study should be referred to by school officials in order to maintain IAQ and as a way of addressing the concerns of parents who want to protect their children’s health.
        4,000원
        14.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study examines the effects of surrounding outdoor environmental characteristics in multi-use public facilities that are used by the susceptible population, on the concentration and distribution of indoor airborne bacteria. For this study, areas were divided into ‘factory area,’ ‘city area,’ and ‘forest area.’ The research was conducted from October 2017 to April 2018, and the selected target facilities were daycare centers, hospitals, postpartum care centers, and nursing homes for the elderly. In order to measure airborne bacteria, indoor air samples were collected using a six-stage viable particulate cascade impactor, and airborne bacteria samples were collected using MCE (Mixed cellulose esters) filters. Moreover, the outdoor airborne bacteria concentration was also measured to determine the concentration ratio (I/O ratio) of the total indoor airborne bacteria and total outdoor airborne bacteria concentrations. The results showed that the total outdoor airborne bacteria concentration was highest in the city area, with 74.2 ± 60.0 CFU/m3, and the lowest in the factory area, with 45.9 ± 35.8 CFU/m3. Furthermore, the distribution of the total outdoor airborne bacteria concentrations significantly differed across each surrounding environment (p < 0.05). On the other hand, no statistically significant difference in total indoor airborne bacteria concentrations, according to surrounding environments, was observed (p > 0.05). These findings suggest that the concentration of outdoor airborne bacteria differs across surrounding environments, unlike that of the indoor airborne bacteria.
        4,300원
        17.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 귀추적 탐구 중심 야외 지질 답사 교육의 실제에 대한 설명을 제공하기 위해, 명시적 지질학 지식 및 탐구 학습 도입 전·후의 지질 답사에서 나타난 학생들의 귀추 수행 특징을 살펴보았다. 이를 위해 사전 평가, 초기 답사, 명시적 지질학 지식 및 탐구 학습, 후기 답사, 사후 평가 등의 순서로 진행되는 21차시의 프로그램을 개발하여 중학생 9명에게 적용했다. 연구 자료로서 야외 지질 답사 수업 녹화·녹음 자료 및 학생 활동지가 수집되어 질적으로 분석되었다. 연구 결과, 초기 답사에서 학생들은 지질학적 중요도가 낮은 단서를 포착했고, 해당 단서의 생성 원인에 대한 가설 생성을 요구받자 일상 경험 및 일반 과학 지식을 규칙으로 활용했으며, 생성된 가설을 규칙의 과학성이나 임의적 기준에 의해 평가했다. 한편, 후기 답사에서 학생들은 지질학적 핵심 단서를 포착했고, 자발적으로 해당 단서와 관련된 지질학적 사건 가설을 지질학 개념을 규칙으로 차용해 생성했으며, 생성된 가설을 관찰 증거와 규칙의 정합성을 바탕으로 과학적으로 평가했다. 이러한 결과를 종합하여, 지질 답사에서 능숙한 귀추 수행을 위해 학습자의 지질학 지식과 탐구(귀추) 역량이 미치는 영향을 경로로 제시했다.
        6,100원
        18.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As the population of consumers of outdoor wear expands, there is increasing interest among consumers in trendy lifestyle outdoor. Accordingly, it is essential to develop designs that are drawn from outdoor wear. This can be limited to traditional mountaineering suits, and designs developed from men’s outdoor zip-up T-shirts, which are highly utilized in everyday life, are very important. This study developed the design of a summer zip-up T-shirt for men with both functional and aesthetic qualities. Visual images of foreign brands and domestic outdoor-focused T-shirts from the spring/summer seasons of 2013-2019 were collected to analyze the following modeling elements: silhouettes, details, colors, materials, and prints. In addition, the design concept was derived by analyzing presentations from the global outdoor trade Fairs (2013-2019). To develop a sustainable eco-friendly outdoor summer T-shirt for men, the concept was derived according to three categories: eco-friendly, sportismexpressed active elements of sports, and an outro-concept of urban town wear as an outdoor lifestyle. Thus, a total of 12 styles of design were developed. High utilization of the outdoor wear T-shirts (which are also popular as lifestyle wear), is an important aspect of building a segmented lineup of the slow-growing outdoor wear market and supports expansion of the scope of theoretical research on outdoor wear design.
        4,800원
        19.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 한냉지에서 실외기에 서리가 형성되지 않는 난방이 가능한 히트펌프를 개발하고자 한다. 그래서 실내에서 –25℃의 환경을 제공할 수 있는 항온기 및 실험챔버를 구성하였다. 실험장치 내에 설치된 히트펌프의 실외기 전면에 도달하는 공기의 특성을 파악할 필요가 있어 범용소프트웨어인 ANSYS CFX를 이용하여 유동해석을 하였다. 그 결과 시뮬레이션 조건(5.0∼7.0 m/s)의 모든 영역에서 실외기 전방에 도달하는 공기의 유속이 자연상태와 다르게 분포함을 파악하였다. 따라서 실외기 전면에 일정한 공기 유속이 도달할 수 있도록 별도의 공기분배기를 추가 설치할 필요가 있다고 판단된다.
        4,000원
        20.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Outdoor air pollution with particulate matter has become more severe in Korea. Ambient particle concentration affects the indoor environment through various routes through building envelopes. In this study, we investigated particle exposure in residential buildings. Indoor and outdoor particle sources determined the indoor concentrations and particle exposure. This paper measured indoor particles and CO2 concentrations in two different apartment buildings and conducted the survey for 24 hours. The I/O ratio of the occupant awake period was higher than the asleep period. The I/O ratio in the awake period is 0.93-3.65, while the I/O ratio in the asleep period is 0.31- 0.76.Indoor peak events such as cooking or cleaning temporarily increase the I/O ratio and emit the indoor particle sources. Decay rate constant is 0.49-6.84 (1/h) in the indoor peak events during the operation of the exhaust hood and natural ventilation. The size range of 0.3-0.5 μm size is over half for the proportions of emitted particles (55.6%). Daily exposure is divided into indoor sources (45.2%) and outdoor sources (54.8%). We found the differences for the proportion of particle exposure. The ratio of daily exposure in particles for 0.3-0.5 μm size is 43.1 (indoor)/ 56.9 (outdoor) %. However, indoor sources are higher than outdoor sources for the ratio of daily exposure in particles for the 0.5-10.0 μm size.
        4,000원
        1 2 3 4 5