검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 32

        21.
        2013.08 KCI 등재 서비스 종료(열람 제한)
        Ozone concentrations in water and air, and resulting disinfective properties, were measured following generation by either an ozone generator or a low-temperature dielectric barrier discharge plasma generator. In freshwater, ozone concentrations of 0.81 and 0.48 mg/L O3 were observed after the ozone and plasma generators had been operated for five minutes, respectively. Higher levels of dissolved O3 were attained more easily with the ozone generator. In seawater, both systems were capable of creating concentrations greater than 3.00 mg/L O3 after 5minutes of operation. Higher ozone levels were attained more easily in seawater than in freshwater. Rates of bacterial sterilization in seawater after three minutes were 96% and 88%, using the plasma and ozone generators, respectively. In freshwater, higher concentrations of ozone were released into the atmosphere by the ozone generator than by the plasma generator. In creating equivalent levels of dissolved ozone in freshwater, the plasma generator released 4.5 times more ozone into the atmosphere than did the ozone generator. This shows that ozone generators are more effective than plasma generators for creating ozonated water. For the same concentration of dissolved ozone in seawater, more ozone was released into the atmosphere using the ozone generator than using the plasma generator. Therefore, with regard to air pollution, plasma generators seem to be less expensive than ozone generators.
        22.
        2013.04 KCI 등재 서비스 종료(열람 제한)
        This study, changes in raw water quality is to indicate on the efficiency of ozone treatment of each pollutant as compared to derive the appropriate operating measures. The appropriate selection for injection rate of pre-ozone and did not inject pre-ozone assess changes in the water. When good water quality, you not injected of pre-ozone to evaluate the economic efficiency of electricity and put the most cost-effective ozone concentration were evaluated. Evaluation remove organic matter and chlorophyll-a concentration level in experiments with each factor of the water DOC> 2.5 ㎎ / L, THMFP> 70 ㎍ / L, Chl-a> 30 ㎎/ ㎥or less constant process, if you do not need to put pre-ozone showed little impact. It also does not put you in pre-ozone appropriate produce enough power rate savings was calculated as approximately 90 million won. Ability to remove organic materials and the ability to produce disinfection byproducts, and cost-effective decisions by considering the concentration of injection if pre-ozone 1 mg/L was investigated by the appropriate concentration of ozone injection.
        23.
        2013.04 서비스 종료(열람 제한)
        This study utilized atomic force microscopy (AFM) and nanoindentation methods to evaluate epoxy water-resistance and anti-corrosiveness. This study considered two different epoxy formulations to assess typical degradation characteristics of epoxy surfaces with regard to water-resistance and anti-corrosiveness. As a result, this study was able to clearly confirm changes in physical characteristics and performance tendencies regarding ozone oxidizing reactions.
        24.
        2012.02 서비스 종료(열람 제한)
        최근 수자원 내에서 미량오염물질이 번번히 발견되고 있고(Lee, 2012) 이중 항생제 내성도 하나의 미량 오염물질로 간주 될 수 있다. 수자원내 항생제 내성 유전자는 환경 내 항생제 내성균의 증가를 일으켜 궁극적으로 병원균 내의 항생제 내성균의 증가를 초래할 수 있다(Kim et al., 2010). 소독은 병원성 미생물 및 잠재적 위해성을 가진 미생물을 불활성화 시키기 위한 공정이며, 수처리 공정에서 소독방법은 염소소독, 오존, UV 또는 전자빔이 선택되어 왔다(Gehr et al., 2003). 본 연구에서는 강력한 산화 기법중의 하나인 오존 소독과 전통적 기법인 염소소독을 비교하는데 목적이 있다.
        25.
        2011.12 KCI 등재 서비스 종료(열람 제한)
        Ecological toxicity testing of the whole-effluent from the ozone ballast water treatment system was conducted as specified in the quality assurance project plans (QAPP). The growth inhibition test with microalgae, acute aquatic toxicity test with the Rotifer reproduction, toxicity test (or population growth) with the Rotifer, survival and growth toxicity test with larval fish and sediment toxicity test with amphipod were carried out to evaluate ecological toxicity on the movile test barge.
        26.
        2010.04 KCI 등재 서비스 종료(열람 제한)
        밸러스트수 처리를 위한 Plasma Gun의 전기적 특성과 오존 생성에 미치는 주요 운전변수들의 영향에 관해 실험실 규모 연구를 수행하였다. 방전개시전압보다 높은 전압이 인가되면 방전이 시작되고 오존이 생성되었으며 전압이 증가함에 따라 기체로 전달되는 에너지 및 오존 농도가 거의 선형적으로 증가하였다. 오존 생성 측면에서 최적의 에너지 효율성을 얻을 수 있는 전극간 거리가 존재하였으며 실험된 장치에서는 1.95 mm의 전극간 거리에서 최적 효율이 얻어졌다. 전기에너지 특성에 미치는 내부전극 재질의 영향은 무시할만한 수준이었으나 내부전극의 전기전도도와 열전도도 차이가 오존 생성에 큰 영향을 미치는 것으로 나타났다. 일정한 Plasma Gun 구조에서 오존 생성은 기체로 전달되는 에너지밀도에 의해 중요한 영향을 받는 것으로 나타났으며 유입되는 기체의 산소함량이 증가할수록 오존 생성이 증가하는 것으로 나타났다.
        27.
        2005.06 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        저장 중 포장 참외의 품질 유지를 위하여 포장과 세척방법을 달리하면서 참외에 대한 품질 평가를 실시한 결과, 저장기간의 경과에 따라 중량 및 경도는 감소하였으며 저장 12일 후부터는 오존수를 이용하여 세척한 처리구를 제외한 모든 구에서 심한 부패 및 손상이 발견되었다. 또한 관능평가 결과, 오존수 세척구에서 색, 외관, 맛, 조직감 모두 가장 높은 점수를 얻었으며 저장 후기에도 반점이 거의 생성되지 않고 부패정도가 가장 미비하여 외관에 대한 우수
        28.
        2004.07 KCI 등재 서비스 종료(열람 제한)
        Evaluated were household THMs exposure associated with the use of municipal tap water treated with chlorine and with ozone-chlorine. The current study measured the THMs concentrations in the tap water and indoor and outdoor air in the two types of household, along with an estimation of THMs exposure from water ingestion, showering, and the inhalation of indoor air. Chloroform was the most abundant THMs in all three media, yet no bromoform was detected in any sample. Contrary to previous findings, the fall water THMs concentrations exhibited no significant difference between the chlorine and ozone-chlorine treated water. However, the spring median chloroform concentration in the tap water treated with chlorine (17.6 ppb) was 1.3 times higher than that in the tap water treated with ozone-chlorine (13.4 ppb). It is suggested that the effects of the water parameters should be considered when evaluating the advantage of ozone-chlorine disinfection for THMs formation over chlorine disinfection. The indoor air THMs concentration trend was also consistent with the water concentration trend, yet the outdoor air THMs concentrations did not differ significantly between the two types of household. The indoor to outdoor air concentration ratios were comparable with previous studies. The THMs exposure estimates from water ingestion, showering, and the inhalation of indoor air suggested that, for the residents living in the surveyed households, their exposure to THMs in the home was mostly associated with their household water use, rather than the indoor air. The THMs exposure estimates from tap water ingestion were similar to those from showering.
        29.
        2004.01 KCI 등재 서비스 종료(열람 제한)
        The effect of ozone on the formation and the removal of disinfection byproducts(DBPs) of chlorination process was studied to elucidate the performance of water treatment process. The samples of raw water, prechlorination process, and preozonation process were analyzed quantitatively according to the Standard Methods for the Examination of drinking water. As a result, most of total trihalomethanes(THMs) which were formed in prechlorine treatment process was not removed in the preozonation process. Most of haloacetic acids(HAAs), haloacetonitriles(HANs), and chloral hydrate(CH) was removed in sedimentation and biological activated carbon(BAC) filtration processes. However, DBPs were increased more or less by postchlorine step. In particular, the formation of THMs and HAAs depends on ozone more than chlorine, but, the formation of HANs and CH depends on chlorine more than ozone. The seasonal variation of DBPs concentration for the year needs to be investigated to study the temperature effect because DBPs strongly depend on temperature among various efficient factors.
        30.
        2002.12 KCI 등재 서비스 종료(열람 제한)
        This study was carried out to evaluate the pollutant removal efficiencies of the advanced drinking water treatment using ozonation process. For raw water, Nakdong River was used. By conducting batch test of ozonation, the following results were obtained. When ozone dosage of 5 mg/ℓ was used, ozone transfer and utilization efficiencies of the ozonation were 94 to 92%, respectively. Removal efficiencies of single VOC compound or mixed VOC compounds in the raw water were 80% to 90% by the ozonation with 2 mg/ℓ dosage and 10 minutes contact time. Removal efficiencies of ABS by the ozonation with 1 mg/ℓ, 3 mg/ℓ dosage and 20 minutes contact time were 83% to 96% , respectively. Almost 67% of chlorophyll-a at the concentration of 38.4㎍/ℓ was removed by ozonation at ozone dosage of 1 ㎎/ℓ for 20 min. Considering the efficiency of ozone utilization and water treatment, the most effective ozonation could be obtained with high ozone dosage and short contact time.
        31.
        2001.12 KCI 등재 서비스 종료(열람 제한)
        This study was carried out to evaluate the pollutant removal efficiencies of the advanced drinking water treatment using ozonation. For raw water, Nakdong River was used. By conducting batch ozonation test, the following results were obtained. When ozone dosage of 5㎎/ℓ was used, preozonation of raw water reduced turbidity, KMnO4 consumption, DOC(dissolved organic carbon), UV254 absorbance, THMFP(trihalomethane formation potential) as much as 3.9 NTU, 5.5㎎/ℓ, 1.15㎎/ℓ, 0.112 and 0.065㎎/ℓ, respectively. In case of postozonation of sand filtered water, water quality was also improved with decrease in turbidity, KMnO4 consumption, DOC, UV254 absorbance and THMFP at the amount of 0.08NTU, 2.6㎎/ℓ, 0.88㎎/ℓ, 0.042 and 0.018㎎/ℓ, respectively. On the other hand, contents of dissolved oxygen increased at the level of 1.3㎎/ℓ after preozonation process' and 1.0㎎/ℓ after postozonation process. The effect of ozone dosage was higher than that of its contact time for the removal of the pollutants.
        32.
        2001.12 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        오존수 처리콩나물의 저장 중 품질변화를 조사하였다. 콩나물 재배 중 오존수 처리는 콩의 수침시와 주수시에 물을 사용한 것(W/W), 수침 시만 오존수를 처리한 것 (O/M), 주수 시에만 오존수를 처리한 것 (W/O), 수침시와 주수시에 각각 처리한 것(O/O)으로 나누어 각각 5일간 재배하였다. 저장은 콩나물을 0.01 mm polyethylene film 에 포장하여 1와 2에서 저장하였다. 저장수명은 오존수 처리와 무처리간의 뚜렷한 차이를
        1 2