검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2012.09 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        This study was performed in the 48 selected public facilities in three metropolitan cities (Seoul, Daejeon, and Kwangjoo) and three general cities (Suncheon, Gwangyang, and Yeosu) to measure of the characteristics from May to October 2011. Air samples (PM2.5) were collected at the indoor and outdoor places for 24-hrs using the mini volume air sampler and analyzed 24 gaseous and particulate polycyclic aromatic hydrocarbons (PAHs) through the GC/MS. The recoveries of gaseous and particulate PAHs ranged between 60.7% to 127.2% and 57.7% to 132.5% respectively and its relative standard deviation (RSD) was 11.1%. This QA/QC results about the were adequate for the Korean national standards. The concentration levels of the PAHs in present study were acenaphthene 〉dibenz(a,h)anthracene 〉benzo(g,h,i)perylene 〉3-methylcholanthrene 〉 indeno[1,2,3-cd]pyrene for the particulate PAHs in the 48 selected public facilities. In the case of acenaphthene, the mean concentration showed the highest levels of 22.42 ng/㎥ and 34.57 ng/㎥ in the level of gaseous and particulate phase, respectively. The total PAHs concentration for the PC room is the highest in surveyed public facilities of this study and the smoking/non smoking ratio in the PC room was 3.45. This results indicated that smoking in the PC room is seemed to play a major source and the effective risk management strategies were needed to minimize or eliminate the public health effect for customers in the PC room.
        5,400원
        2.
        2007.03 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        To investigate characterization of EMF(Electromagnetic Field) emission from VDT(Visual Display Terminal) in computer room, we were divided into 3 types of placement monitors which are 1) back side of monitor faced the ground(back view type), 2) arrangement of monitors was a line type(two sides type), and 3) disposition of monitors was s straight(horizontal line type). We also measured monitors classified types at the front, side and back by distance and evaluated by TCO(The Swedish Confederation of profession Employers) and MPR-2(Measure and Proof Radiation Board) guide line. Magnetic field emission level by the type of VDT, it was indicated that MF(Magnetic Field) level was below the backgrounds level when CRT moved away about 70~90cm, LCD moved away about 40~50cm. We evaluated MF emission level by the number of VDT, it did not show any relationship. Finally, estimated MF emission level by the placement of VDT, it was showed the MF level less than the background level, when VDT moved away 40~50cm in all dispositions with exception of 2 sites. Background level of case was higher than emitted from VDT, so that did not effect on MF level by distance. However, we find out that as distance increased, MF emission level decreased significantly in all cases. We measured MF emission level of one monitor and others (back and forth) monitor in line type. Below the background level when one monitor type moved away 70cm, others monitor type moved away 40cm. However, other monitor types affected MF level which is located back monitor. The data demonstrate that avoiding excessive MF exposure from VDT using computer room, to have a space between user and VDT at least 50㎝.
        4,000원
        3.
        2004.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        The PC game rooms in Korea have a problem in the aspect of indoor air quality because there are many occupants for 24 hours where the smoking is allowed. This study was carried out to evaluate indoor air quality (IAQ) including the size distribution of respirable suspended particulates (RSP) and airborne nicotine concentration in selected PC game rooms. The subjects are 6 PC game rooms in Seoul and Sung-Nam Cities. In this study, airborne RSP and nicotine concentrations were measured during a period from February to March, 2003. Significant correlation has been found between the concentrations of RSP and nicotine in PC game room. Also the negative correlation was found between room area and number of operating fan. The correlation coefficients between RSP size distribution and nicotine concentration were 0.868, 0.866, 0.870 in the stages 2 (cut-point 14.80㎛), 5 (cut-point 3.50㎛), and 8 (cut-point 0.52㎛) from Marple's 8-stage cascade impactor, respectively. In conclusion, RSP concentration in PC game room has a tendency to increase by smoking. Therefore, it is suggested that the effective air control system and education program be applied for PC game room.
        4,600원