There are several methods of peak-shaving, which reduces grid power demand, electricity bought from electricity utility, through lowering “demand spike” during On-Peak period. An optimization method using linear programming is proposed, which can be used to perform peak-shaving of grid power demand for grid-connected PV+ system. Proposed peak shaving method is based on the forecast data for electricity load and photovoltaic power generation. Results from proposed method are compared with those from On-Off and Real Time methods which do not need forecast data. The results also compared to those from ideal case, an optimization method which use measured data for forecast data, that is, error-free forecast data. To see the effects of forecast error 36 error scenarios are developed, which consider error types of forecast, nMAE (normalizes Mean Absolute Error) for photovoltaic power forecast and MAPE (Mean Absolute Percentage Error) for load demand forecast. And the effects of forecast error are investigated including critical error scenarios which provide worse results compared to those of other scenarios. It is shown that proposed peak shaving method are much better than On-Off and Real Time methods under almost all the scenario of forecast error. And it is also shown that the results from our method are not so bad compared to the ideal case using error-free forecast.
본 연구는 4연동 벤로형 유리온실의 냉·난방 부하를 고려한 PV 시스템의 적정 패널 설치 면적을 도출하기 위하여 BES 기법을 이용하여 온실 및 PV 시스템의 에너지 모델을 설계하였으며 동적 에너지 시뮬레이션을 수행하였다. 대상 작물은 파프리카로 선정하였으며 작물의 적정생육온도를 고려하여 냉·난방장치 및 환기장치의 가동조건을 설정하였다. 2012년부터 2016년까지 총 5년 동안의 기간별 냉·난방부하 및 최대 냉·난방 부하를 환 기팬의 환기량 조건 별로 분석을 실시하였다. 온실의 냉 ·난방 부하 산정과 함께 PV 시스템의 설치 각도에 따른 전력 생산량을 분석하였으며 신재생에너지 공급의무비율을 적용하여 최적 PV 시스템 설계 방안을 도출하였다. 환기팬의 환기량 60AE·hr-1 조건에서 대상 온실의 기간 평균 냉방 부하로 인한 전력 소모량은 174,310kWh, 기간 평균 난방 부하로 인한 전력 소모량은 458,903kWh 로 총 633,213kWh의 전력 소모량이 산정되었다. PV 시스템은 설치 각도를 30o로 설정하는 조건에서 가장 높은 전력 생산량이 나타났으며 월별 최적 각도를 적용하는 조건에서는 고정형 PV 시스템보다 약 5.7% 많은 전력 을 생산하는 것으론 산정 되었다. 최종적으로 대상 온실에 적합한 PV 시스템 패널 면적을 도출한 결과, 고정형 PV 시스템은 521m2의 패널이 필요한 것으로 산정되었고, 가변형 PV 시스템의 경우 494m2의 패널이 필요한 것으로 산정되었다. 본 연구를 통하여 4연동 벤로형 유리온실의 냉·난방 부하를 고려한 PV 시스템의 필요 패널 설치 면적을 도출할 수 있었으며 PV 시스템의 온실 적용 가능성 및 경 제성 평가의 기초 자료로 활용 가능할 것으로 판단된다. 한편, 본 연구에서는 작물 특성 데이터를 확보하지 못하여 작물의 에너지 교환을 고려하지 않았다. 보다 정확한 결과를 도출하기 위해서는 현장 실험 데이터에 기반을 둔 추가 연구가 필요할 것으로 판단된다.
목 적 : 본 연구는 심방세동 치료를 위한 전극 도자 절제술(Radio Frequency Catheter Ablation, RFCA)의 3D mapping 기법과의 최적의 영상 융합을 위해 우심방과 폐정맥을 한 번의 호흡정지로 혈관 조영을 할 수 있는 PV-CMRA(Pulmonary vein-Cardiovascular Magnetic Resonance Angiography) 검사법의 유용성을 알아보고자 하였다.
대상 및 방법 : 2014년 10월부터 12월까지 PV-CMRA를 시행한 심방세동 환자 50명(남성 36명, 여성 14명)을 대상으로 하였다. 3.0T 자기공명영상장치(Achieva Philips Medical System, Netherlands)와 32Channel SENSE torso-cardiac coil을 사용하였고, Test bolus injection 후 우심방에 관심영역을 설정하여 신호강도 곡선에서 조영제 Peak time(sec)을 구한 후, 검사 시작 시간과 Dynamic scan수를 정하였고, 조영제는 자동주입기로 매글루민 가도테레이트(meglumine gadoterate, DotaremⓇ)와 생리식염수 60ml를 각각 3.0ml/sec로 오른팔 주정맥에 주입하여 4D time-resolved MR angiography with keyhole(4D-TRAK)기법을 이용하여 PV-CMRA 영상을 획득하였다. 획득된 영상은 협업 과정을 통해 RFCA 3D mapping 기법의 융합 영상과 비교하였다. 통계학적인 검정은 SPSS 21.0(SPSS Inc, Chicago, IL, USA)을 이용해 조영제 Peak time의 변환 인자를 알아보기 위해 우심방과 폐정맥의 신호강도 값과 환자의 나이, 성별, BMI, 최고, 최저혈압(mmHg), HR(Heart Rate) 측정치와 상관분석(p<0.05)을 하였고, PV-CMRA 영상과 3D mapping 영상의 만족도를 각각 5점 척도로 정성적 분석을 하였다.
결 과 : 우심방 조영제 Peak time은 6.5sec이고, 우심방 신호강도 값과의 Pearson 상관분석 결과는 성별(r=-0.043, p=0.765), 나이(r=0.270, p=0.058), BMI(r=-0.003, p=0.981), 최고혈압(r=-0.122, p=0.400), 최저혈압(r=-0.035, p=0.809), HR(r=0.061, p=0.672)로 나타났고, 폐정맥 신호강도 값과의 Pearson 상관분석 결과는 성별(r=-0.186, p=0.197), 나이(r=0.116, p=0.423), BMI(r=0.082, p=0.569), 최고혈압(r=0.107, p=0.459), 최저혈압(r=0.151, p=0.294), HR(r=0.061, p=0.673)은 유의한(p<0.05) 차이가 없음을 알았다. PV-CMRA 영상과 3D mapping 영상의 정성적 분석결과는 유의한 (p<0.05) 차이를 나타냈다.
결 론 : PV-CMRA 검사는 조영제 Peak time에 영향을 주는 유의한 인자가 없으므로, 한 번의 호흡정지로 조영제 주입속도와 검사시작 시간을 일정하게 유지하여 우심방의 영상을 획득하고 Dynamic scan 수를 조절하여 폐정맥의 영상을 획득할 수 있다. 이 영상을 통계학적으로 유의한 차이를 보인 3D mapping 기법과의 협업을 통해 최적의 영상 융합을 조합하면, 기존 PV-CT와 PV-CMR을 대체 및 보완 할 수 있는 검사법으로써 유용할 것으로 사료된다.
This study describes the result on PV system for evaluating the performance of small fishing boats. Photovoltaic system with 200 watts power generation facilities on the 3-ton fishing boat was carried. Load test was performed on the condition that the work lamps lit during night operations. As a result the performance can be used for more than two hours at 60 watt work lamps. The load test was performed on the condition that fishing vessels are on the cruising condition at sea. The solar power systems have been investigated as a power generation efficiency of about 36.55%. Additional tests show that the power generation efficiency is difficult to expect a maximum of 50% or more.Fuel consumption of fishing boats by installing a solar power system is reduced. Also the PV system is useful for the verification of their availability for fishing vessels as well as the satisfaction of the fishermen. The results for the durability of the photovoltaic device is acceptable, including a solar panel, controller and the performance exhibited no breakage in the harsh marine environment or failure so far. The installed PV system was confirmed that the durability with at least 2 years.
Recently, environmental problems associated with the excessive use of fossil fuel are hot issue throughout the world. As an alternative energy resource, the importance of renewable energy is continuously rising. Especially, growth rate of photovoltaic energy generation is one of the best. In this paper, floating PV generation system made of pultruded fiber reinforced polymeric plastic (PFRP) is discussed. It is well known that PFRP has many advantages such as high corrosion resistance, high specific strength/stiffness, etc. Compared with conventional construction materials. To investigate the structural behavior under flow induced dynamic loading, members and connections of members are tested under cyclic loading. It was found that the structural system is strong enough to resist such a cyclic loading.
The EnergyPlus is used for the analysis of energy demand at two rural house models. Photovoltaic (PV) system is installed to reduce the energy demand of annual building. The energy economic analysis is performed to provide quantitative data at choosing a suitable house model. Two types of PV system installations are considered as each building type. Among 4 different cases analyzed through this study, the best setup is provided for 12.3 years at recovering PV system installation cost.
본 연구는 수산 폐기물인 굴패각을 공조시스템의 수분 흡착제로 사용하기 위한 가능성을 실험을 통해 살펴본 기초적인 연구이다. 연구의 주된 목적은 굴패각의 제습성능과 열전소자의 냉각효과를 파악하는 것이며 본 연구를 통해 굴패각은 공조시스템 내에서 사용가능한 수분 흡착제로서의 성능을 충분히 가지고 있으며, 또한 냉각효과를 통해 흡착성능을 크게 향상시킬 수 있다는 것을 알았다. 본 시스템은 신재생에너지인 태양광을 이용하기 때문에 시스템의 구동에 필요한 다른 전원은 필요 없어 환경적으로도 매우 바람직한 연구이다.
전기자동차의 상용화시대에 대비한 전기자동차 충전네트워크가 시급해지고 있다. 해외에서는 주차장에 PV시스템을 설치하여 얻어진 전력으로 전기자동차 충전을 할 수 있는 전기자동차 충전소가 설치되어지고 있다. 또한 우리나라에서도 충전인프라 구축방안 및 전기자동차 충전시설 지원기준 등을 설정하여 제시하고 있지만 해외처럼 PV시스템을 이용한 전기자동차 충전소의 사례가 국내에는 없으며, 일반전력을 이용한 전기자동차 충전소만 제시하고 있다. 따라서 본 논문에서는 국내의 전기자동차 충전네트워크 구축에 대비하여 국내 외 태양광 주차장과 해외 PV시스템 전기자동차 충전소의 사례를 조사하여 구조시스템, 구조 재료 등을 분석하여 비교 분석한 결과, 해외 PV시스템 전기자동차 충전소의 경우 캔틸레버 구조와 소규모 타입이 많이 설치되었다.
In this paper, the structural characteristics of the tracking-type floating PV generation system are presented. Moreover, the structural safety of each tracking-type floating PV generation system is estimated from the analytical results obtained by the finite element analyses.
The floating PV generation system is consisted of unit structures linked by the hinge type connection because the effect of bending moment in the structural system loaded due to the unstable movement of water surface can be minimized. In this paper, the investigation and development process of floating PV generation unit structure is presented.