검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 160

        61.
        2011.12 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        The aim of this study was to compare the concentrations of airborne pollutants (i.e., PMs, TVOC, and ozone) released from a laser printer with a new and/or a refilled toner cartridge. Also we compared the concentrations before and after attaching a HEPA filter at the outlet of exhausted air for each printer. PMs, TVOC, and ozone were released from all three different branded printers with both toner cartridges in accordance with their both a brand new and a used condition. For PMs, there were generally significant differences of concentrations between a brand new and used toner (p<0.05). Ozone level differences were found between a new and a refilled toner, but were not significant (p>0.05). For TVOC, there were significant differences of concentrations among brands, and toluene (3.46mg/m3) only was identified. The overall 70% of reduction for PMs’concentrations occurred after attaching a HEPA filter(p<0.05), and these results were pronounced for TSP. These results showed that similar levels of airborne pollutants were released from a laser printer with a new and a refilled toner cartridge. Also, these results indicate that the usage of a HEPA filter may be an effective method for reducing the released pollutants from a laser printer.
        4,300원
        62.
        2011.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Activated carbon was prepared from pre-carbonized petroleum coke. Textural properties were determined from studies of the adsorption of nitrogen at 77 K and the surface chemistry was obtained using the Fourier-transform infrared spectrometer technique and the Boehm titration process. The adsorption of three aromatic compounds, namely phenol (P), p-nitrophenol (PNP) and benzoic acid (BA) onto APC in aqueous solution was studied in a batch system with respect to contact time, pH, initial concentration of solutes and temperature. Active carbon APC obtained was found to possess a high surface area and a predominantly microporous structure; it also had an acidic surface character. The experimental data fitted the pseudo-second-order kinetic model well; also, the intraparticle diffusion was the only controlling process in determining the adsorption of the three pollutants investigated. The adsorption data fit well with the Langmuir and Freundlich models. The uptake of the three pollutants was found to be strongly dependent on the pH value and the temperature of the solution. Most of the experiments were conducted at pH 7; the pH(PZC) of the active carbon under study was 5.0; the surface of the active carbon was negatively charged. The thermodynamic parameters evaluated for APC revealed that the adsorption of P was spontaneous and exothermic in nature, while PNP and BA showed no-spontaneity of the adsorption process and that process was endothermic in nature.
        4,000원
        63.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        도로에서의 강우유출수 내 포함된 오염물은 주요한 비점오염원으로 간주되고 있으며 비점오염물질 저감을 위하여 많은 대책이 적용되고 있다. 도로청소에 의한 방법 또한 오염물의 강우유출에 의한 배출양을 감소시킬 수 있는 대책 중의 하나로 인식되는 추세에 있다. 본 연구에서는 도로청소 시 수거된 토사입자들의 특성을 파악하고 퇴적토사에 함유된 오염물질의 농도를 분석하였다. 분석결과를 바탕으로 하여 도로 구간별로 도로청소에 의하여 저감할 수 있는 오염물의 양을 평가하였다. 도로청소를 통하여 수거된 퇴적토사는 모래질로 분석되었으며 세립토 비중은 낮은 결과를 보였다. 퇴적토사 내 오염물의 양은 토양환경기준을 초과하지 않았으나 청소작업시 물을 살수함으로써 토사에 포함된 오염물이 세척되어 침출수로 미리 배출되는 것에 기인한다고 판단된다. 두 도로구역에 대하여 오염물 농도, 발생 퇴적토사량, 오염물 원단위를 적용하여 저감할 수 있는 오염물 양을 평가한 결과, ○○지역에 대하여 TSS 31.4% 및 △△지역에서는 TSS 7.7%의 TSS 저감량이 도출되었다. 중금속과 같은 타 오염물의 경우 훨씬 낮은 저감량이 평가되었으나 이는 물의 살수로 인하여 퇴적토사 내 오염물이 침출수로 배출된 것에 기인한다고 판단된다. 보다 정확하게 도로청소에 의하여 저감할 수 있는 오염물의 양을 산정하기 위하여 보다 자세하고 체계적인 연구가 필요하다고 판단된다.
        4,000원
        64.
        2010.12 KCI 등재 구독 인증기관·개인회원 무료
        Many researchers reported biodegradation of environmental pollutants by white-rot fungi. Toward in situ bioremediation, we have investigated biodegradation of environmental pollutants by litter-decomposing fungi. In our results, lignin-degrading enzymes produced from litter-decomposing fungi are thought to participate in degradation of pentachlorophenol (PCP) and 2,4-dichlorophenoxy acetic acid (2,4-DA). Then, we examined the biodegradation of PCP, 2,4-DA and the analogs of 2,4-DA by purified laccase and the role of redox mediator on laccase reaction. Laccase purified from Calvatia craniiformis decomposed phenolic compounds, PCP and 2,4-dichlorophenol (2,4-DP), but not non-phenolic compounds, 2,4-DA and 2,4-dichlorophenoxy ethanol (2,4-DE), even in the presence of redox mediators. To clarify the reaction mechanism between the substrates and redox mediators, quantum chemical analysis was applied using MOPAC 2009 and Gaussian 03. The results of the heat of formation and the perturbation energy showed that even redox mediator radicals could not oxidize the non-phenolic compounds. Previously several reports showed that laccase-redox mediator systems decomposed non-phnolic compounds, but we propose that the system could not react on the chlorinated aromatic compounds based on the result of quantum analysis.
        65.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 비점오염원에 대한 관심이 높아지면서, 환경부 및 유관단체를 중심으로 노면 유출수를 포함한 비점오염원(Non point source)에 대한 현황 조사 및 처리 방법에 대한 관심이 증가하고 있다. 고속도로 휴게소 주차장 노면 유출수는 고속도로 본선 노면 유출수보다 유해물질 오염도가 높을 것으로 예상되어, 본 연구는 이 지역의 노면 유출수 오염도 조사를 통해 유출수 평가 및 노면 유출수 저감시설의 저감효과를 분석하여 휴게소 노면유출수 관리방안을 수립하는 것을 목적으로 하고 있다. 휴게소지점에 대한 강우 유출수 분석 결과 포장지역의 특성인 초기강우현상을 볼 수 있었으며, 강우초기에 입자상물질은 중금속과 결합하여 다량 유출되는 특성을 나타내었다. 휴게소 지점의 강우유출수에 대한 오염물질별 EMC에 대한 95% 확신범위로는 TSS 128.2-273.4mg/L, COD 145.4-310.1mg/L, TN 6.1-11mg/L, TP 1.9-2.9mg/L의 범위로 분석되어 고속도로에서 유출되는 강우유출수와 비슷한 수준으로 유출되는 것으로 분석되었으나, 중금속의 경우 고속도로에 비해 고농도의 중금속이 유출되는 것으로 나타났는데, 이것은 차량 정차시 브레이크 패드나 타이어의 마모등에 의한 것으로 판단된다. 휴게소지점에 대한 면적당 발생되는 부하량 통계분석결과, TSS의 평균 부하량은 1411.6mg/m2로 산정되었으며, COD 709.7mg/m2, TN 44.0mg/m2, TP 10.4mg/m2로 산정되었다. 중금속의 경우 Total Cu 12927.4μg/m2, Total Fe 32074.4μg/m2, Total Pb 40371μg/m2, Total Ni 10679.2μg/m2로 산정되었다.
        4,000원
        67.
        2010.04 구독 인증기관 무료, 개인회원 유료
        본 연구는 최종 해양에 배출되는 하수슬러지에 함유된 오염물질의 농도와 분포특성을 파악하고자 하였다. 연구에 사용된 시료는 하수 슬러지 발생업체의 최종 저장조에서 20점을 채취하였고 시료의 조제를 비롯하여 최종 기기분석까지 해양환경공정시험기준을 적용하였으며, 다 환방향족탄화수소류(PAHs)는 U.S EPA 기준에 맞춰 16종을 분석하였다. 분석결과 중금속인 비소는 최대 15.29 ㎍/g, 카드뮴 2.04 ㎍/g, 크롬 632.98 ㎍/g, 구리 2,388.28 ㎍/g, 납 77.71 ㎍/g, 아연 2,928.28 ㎍/g이었고, 폴리염화비페닐(PCBs) 7종 중 최대값은 0.80 ng/g이고 7종의 합은 ND ~ 2.50 ng/g으로 나타났다. 다환방향족탄화수소류(PAHs)의 각 항목별 최대값은 나프탈렌 1,199.5 ng/g, 아세나프틸렌 35.48 ng/g, 아세나 프텐 104.94 ng/g, 플루오렌 424.86 ng/g, 페난트렌 606.91 ng/g, 안트라센 121.96 ng/g, 플루오란텐 683.64 ng/g, 피렌 1045.70 ng/g, 벤죠(a)안트 라센 270.49 ng/g, 크리센 288.76 ng/g, 벤죠(b)플루오란텐 175.81 ng/g, 벤죠(k)플루오란텐 162.22 ng/g, 벤죠(a)피렌 185.84 ng/g, 인데노 (1,2,3-cd)피렌 136.22 ng/g, 디벤즈(a,h)안트라센 21.60 ng/g, 벤죠(g,h,i)페릴렌 320.00 ng/g으로 나타났다. 한편 분석시료 20점 중 해양배출처리 기준 제1기준을 초과한 시료는 구리 1점이었고, 생물독성시험이 필요한 제2기준을 초과한 시료는 크롬 1점, 구리 10점, 아연 2점, 나프탈렌 3점 으로 나타났다.
        4,000원
        68.
        2010.03 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        The objective of this study was to estimate distribution of hazardous air pollutants and volatile organic compounds at diverse indoor areas in school. The indoor air samples were collected at 19 school in three different areas of southern Korea region from September to October 2009. The concentrations of PM-10 and formaldehyde in all sampling sites were below indoor air quality guideline of the Ministry of Education, Science and Technology. The CO2 level and TBC (total bacteria count) were higher than the guideline for 4 sites and 12 sites, respectively. The concentration of TVOC for 23 sites exceeded the guideline. Also, TVOC level of metropolitan sampling sites were somewhat higher than small and medium-size city sampling sites. The concentration of indoor air pollutants affected by various conditions such as season, region, and indoor/outdoor environment. This study result shows that concentration of several pollutants such as CO2, TBC, and TVOC were higher than the guideline for some sampling sites. Therefore, it is necessary to manage indoor air quality and establish effective emission reduction strategies regard for characteristics of each school.
        4,800원
        69.
        2009.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the adsorption of toxic pollutants onto cetyltrimethylammonium kaolin (CTAB-Kaolin) is investigated. The organo-kaolin is synthesized by exchanging cetyltrimethylammonium cations (CTAB) with inorganic ions on the surface of kaolin. The chemical analysis, the structural and textural properties of kaolin and CTAB-kaolin were investigated using elemental analysis, FTIR, SEM and adsorption of nitrogen at -196℃. The kinetic adsorption and adsorption capacity of the organo-kaolin towards o-xylene, phenol and Cu(II) ion from aqueous solution was investigated. The kinetic adsorption data of o-xylene, phenol and Cu(II) are in agreement with a second order model. The equilibrium adsorption data were found to fit Langmuir equation. The uptake of o-xylene and phenol from their aqueous solution by kaolin, CTAB-kaolin and activated carbon proceed via physisorption. The removal of Cu(II) ion from water depends on the surface properties of the adsorbent. Onto kaolin, the Cu(II) ions are adsorbed through cation exchange with Na+. For CTAB-kaolin, Cu(II) ions are mainly adsorbed via electrostatic attraction with the counter ions in the electric double layer (Br-), via ion pairing, Cu(II) ions removal by the activated carbon is probably related to the carbon-oxygen groups particularly those of acid type. The adsorption capacities of CTAB-kaolin for the investigated adsorbates are considerably higher compared with those of unmodified kaolin. However, the adsorption capacities of the activated carbons are by far higher than those determined for CTAB-kaolin.
        4,000원
        70.
        2009.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The risk assessment for heavy metal pollutions were analyzed by using statistical techniques including correlation and cluster analyses. The contamination data in this investigation obtained were from the Chungcheongnam-do abandoned mines. The descriptive statistical analysis showed that the values of Pb and Zn were relatively higher than other heavy metal values. The detection of heavy metals by distance from abandoned mines within 1,000m were mostly As, Cd, Pb, and Zn. It was noted, especially, that Zn was even detected at 4,000m The results of coefficient correlation showed that Zn to Cd was the highest values. The cluster and dendogram analyses were generated. The results showed the two clear groups by heavy metal characteristics.
        4,000원
        71.
        2009.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to identify hazardous physical factors and chemical air pollutants in conservation museum in order to protect the cultural heritage. For this, we collected and re-analyzed the articles that were published from 2006 to 2007 by National Research Institute of Cultural Heritage for temperature, relative humidity and the level of pollutants (PM10, CO2, HCHO, CO, NO2, Rn, TVOCs, O3, SO2) in exhibition hall and storage in museum. The pooled average level of temperature at exhibition hall and storage in museum was 23.5±1.4℃ and 20.6±1.1℃, respectively. The range of temperature variation was 5.4℃ for exhibition hall and 4.5℃ for storage. The pooled average concentration of TVOCs in exhibition hall and storage in museum was 493.6±125.6㎍/m3 and 788.9±157.5㎍/m3, respectively. These exceeded 400㎍/ m3 which is the guideline of national law for the Korean Ministry of Public Administration and Security (KMOPAS). Other surveyed pollutants were as per the guidelines of the national law for the Korean Ministry of Environment (KMOE) and the KMOPAS. Through the consideration of the physical and chemical properties and the result of meta-analysis for thermal environment and surveyed temperature, humidity, PM10, NO2, SO2, O3, TVOCs, and HCHO were the identified hazardous physical factors and chemical pollutants at exhibition halls and storages in museum.
        4,600원
        72.
        2007.12 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        This study was surveyed to evaluate and recognize the distribution characteristics of indoor air pollutants(IAPs) such as the total volatile organic compounds(VOCs), formaldehyde(HCHO), PM10, carbon dioxide(CO2), nitrogen dioxide(NO2), ozone(O3) and radon in 10 elementary schools located in urban, rural, and industrial complex area from November 2005 to February 2006. The average concentration of IAPs were 117.9㎍/㎥ as in PM10, 1,971ppm as in CO2, 486.6㎍/㎥ as in TVOC. These chemical's concentration was exceeded the indoor air standards of the Department of Education in Korea. The indoor concentrations of ozone and toluene was lower than that of outdoor and other pollutants showed the opposite tendency. In schools located industrial complex area, the outdoor concentration of TVOC was higher than that of urban and rural area. Based on the results above, PM10, CO2, TVOC have to be in the order of priority to improve the indoor environment in school. Also it should be performed in the detailed survey considered by the seasonal variation because this study showed cross-sectional results.
        4,000원
        73.
        2007.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        터널 내 축적된 다양한 오염원들은 간헐적으로 수행되는 세척과정 중에 폐수로 배출되게 되며, 서울 시내 3개 터널 지점에서 수행된 수질분석결과 SS, CODCr, T-N, NH3-N, NO3-N, Zn, Cu, Cr(+6). Mn, Mg, Phenol. CN-, E-Coli 등이 고농도 형태로 배출되는 것으로 나타났다. 한편, 이러한 오염수질의 배출농도 특성은 터널 세척 폐수의 채취 방법, 세척횟수, 세척수량, 터널내벽 특성, 통행량, 배수 특성 등에 따라 다양한 농도범위를 보여주는 것으로 나타났다. 한편, 수집된 터널 세척폐수를 단순 중력침전을 이용하여 저감실험을 수행한 결과, CODCr는 80%, T-N, T-P는 각각 30, 90% 제거됨을 확인하였고, 중력침전 분리를 통하여 제거되지 않은 잔여 오염물질에 대하여 GAC 소재를 통한 흡착실험(터널 세척폐수 1l에 대하여 GAC를 50g을 투입) 결과, CODCr, T-N, Zn, Cu, Mn, Phenol, CN 항목에서 80% 이상 제거됨을 확인하였다.
        4,000원
        74.
        2007.03 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        Burning mosquito coils in indoor environments maygenerate smoke that can control mosquito effectively. This practice has been used in numerous households in Korea. However the smoke may contain air pollutants of health concern. We conducted the present study to characterize the emission from two common brands of mosquito coils from Vietnam and Malaysia, respectively. We measured mass emission of air pollutants of nitrogen oxides (NOx), fine particulate(PM2.5), formaldehyde (HCHO), total volatile organic compounds (TVOCs), carbon monoxide (CO) and carbon dioxide (CO2) in completely closed chamber. Air pollutants concentrations resulting from burning mosquito coils could substantially exceed health-based air quality standards orguidelines. Under the same condition, air pollutants were measured by cigarette smoking to compare mosquito coil. Burning one mosquito coil would release the same amount of PM2.5 mass as burning 20~58 cigarettes. The emission of HCHO from burning one coil can be as high as that released from burning 27 cigarettes.
        4,000원
        75.
        2007.03 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        This study was to investigate distribution characteristics for air pollutants and to assess probability of health effect for children in kindergartens from August, 2006 to January, 2007. The mean concentrations for standards of maintenance in kindergartens were 91.5 ㎍/㎥ for PM10, 1,185 ppm for CO2, 69.3㎍/㎥ for formaldehyde, 174 CFU/㎥ for TBC and 0.41 ppm for CO, respectively. For NO2, Rn, TVOC, and O3, the mean concentrations in kindergartens were 29.40 ppb, 1.51 pCi/ℓ, 257.3 ㎍/㎥, and 3.74 ppb, respectively. The I/O ratio of every air pollutants exceeded "1" except for O3. In results of calculated safety factor to assess probability of health effect for children by air pollutants in kindergartens, safety factor for CO2 was 1.2 for fixed point. It means that children have probability of health effect caused by CO2. In cases of Monte-Carlo analysis, safety factor for PM10 was 1.0 and safety factor for CO2 was 1.2.
        4,000원
        76.
        2007.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        동아시아에서 광역적인 대기오염 이동과 한반도 유입을 인공위성과 지상 관측을 통해 5개의 사례를 분석하였다. 이 사례들은 주로 중국 대륙의 도시와 산업지대에서 배출된 오염물질들이 황해를 지나 한반도에 상륙 및 통과하는 광역적인 대기오염 이동이다. NOAA인공위성 관측 자료의 분석은 가시영역과 적외선 영역의 3개 채널을 합성하여 영상을 만들고, 황해 위에서 대기오염의 분포와 이동을 구별해 낼 수 있었다. 또한 청원의 배경관측지점에서 대기오염의 지상 관측 자료는 인공위성 관측 자료와 비교하여 검증하는데 매우 가치가 있었다. 특히, 광역적 대기오염의 이동 사례에서는 PM10과 PM2.5 농도의 차이가 적으면서, PM2.5값이 높게 증가한다. 그러나 황사의 경우는 PM10 농도가 훨씬 높게 관측되어 PM2.5와의 차이가 매우 큼이 특징적이다. 2006년 1월 27일의 사례에서는 중국 발원의 광역적 대기오염이 한반도의 중부 및 남서지역으로의 유입을 인공위성뿐 아니라 여러 지상관측소들에서 순차적으로 관측할 수 있었다. 북북서 기류가 제주도 한라산을 넘어서 풍하측 멀리까지 구름을 소산시키고 대기오염을 감소시키며, 카르만 소용돌이를 만들고 있었다.
        4,500원
        77.
        2006.12 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        This study was carried out to evaluate the characteristics of volatile organic compounds (VOCs) and aldehydes emission as a function of airtight time in new apartment. Sampling was undertaken at 34 new apartments located in 4 different cities of Korea from February to November 2005. The measurement data were collected every one hour from 10 a.m. to 6 p.m. toward increasing airtight time in a day. The concentrations of VOCs and aldehydes were analysed by GC/MS and HPLC method, respectively. These methods showed good sensitivity, linearity, and repeatability. In this study, the most abundant compounds at new apartments appeared to be toluene, m,p-xylene, formaldehyde and acetone. Moreover, the concentration variations at a closed rooms progressively increased by airtight time of 5 hours. Airtight time of new apartment was a most important and affective factor which influenced concentration change.
        4,300원
        78.
        2006.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The treatment of piggery wastes was carried out at pilot scale using a multilayered metal-activated carbon system followed by carbon bed filtration. The physicochemical properties were obtained from treated samples with aqueous solutions containing metallic ions such as Ag+, Cu2+, Na+, K+ and Mn2+, which main obsevations are subjected to inspect surface properties, color removal properties by Uv/Vis and EDX. Multilayered metal-activated carbons were contacted with waste water to investigation of the simultaneous catalytic effect for the COD, BOD, T-N and T-P removal. The removal results for the piggery waste using multilayered metal-activated carbon bed was achieved the satisfactory removal performance under permitted values of Ministry of Environment of Korea. The high efficiency of the multilayered metal-activated carbon bed was determined by the performance of this material for trapping, catalytic effect and adsorption of organic solid particles.
        4,000원
        79.
        2006.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The electro-chemical removal (ECR) of water pollutants by metal-ACF electrodes from wastewater was investigated over wide range of ECR time. The ECR capacities of metallic ACF electrodes were related to physical properties such as adsorption isotherm, surface area and pore size and to reaction time. Surface morphologies and elemental analysis for the metal supported ACFs after electro-catalytic reaction were investigated by scanning electron microscopy (SEM) and energy disperse X-ray (EDX) to explain the changes in adsorption properties. The IR spectra of metallic ACFs for the investigation of functional groups show that the electro-catalytic treatment is consequently associated with the removal of pollutants with the increasing surface reactivity of the activated carbon fibers. The metal-ACFs were electro-catalytically reacted to waste water to investigate the removal efficiency for the COD, T-N, NH4-N, NO3-N and NO2-N. From these removal results of the piggery waste using metallic ACFs substrate, satisfactory removal performance was achieved. The removal efficiency of the metallic ACFs substrate was mainly determined by the properties of the material for adsorption and trapping of organics, and catalytic effects.
        4,000원
        80.
        2006.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        This study performed and re-analysed the articles of exposure assessment for the indoor environment of houses in many environment-related journals published. in Korea since 1990. Based on this comparative study, we estimated the unit health risk on indoor environment. The objective of this study was to offer scientific data for decision-making policy for improvement and management of indoor air quality on Korean house in. The pooled concentrations for the critical air pollutants in the house were 13.93±13.91㎍/m3 (PM10), 680±226 ppm for (CO2), 1.9±1.6 ppm (CO), 419±158 CFU/m3 (bacteria), 0.036 ± 0.002 ppm (NO2), and 104.935 ± 16.424 Bq/m3 (Rn), The pooled concentrations for the volatile organic compounds were 6.9±6.7㎍ /m3 (benzene), 39.3±55.1㎍/m3 (toluene), 4.2±4.0㎍/m3 (ethylbenzene), 11.4±8.3㎍/m3 (m, p-xylene), 4.2 ±1.5㎍/m3 (styrene) and 6.3±4.5㎍/m3 (o-xylene). The unit cancer risk for men and women by inhalation of benzene was 3.7 × 10-5 and 4.8 × 10-6, respectively. In additio
        5,400원
        1 2 3 4 5