검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 12

        1.
        2023.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, a dynamic centrifuge model test was conducted on a 24.8-meter-deep excavation consisting of a 20 m sand layer and 4.8 m bedrock, classified as S3 by Korean seismic design code KDS 17 10 00. A braced excavation wall supports the hole. From the results, the mechanism of seismically induced earth pressure was investigated, and their distribution and loading points were analyzed. During earthquake loadings, active seismic earth pressure decreases from the at-rest earth pressure since the backfill laterally expands at the movement of the wall toward the active direction. Yet, the passive seismic earth pressure increases from the at-rest earth pressure since the backfill pushes to the wall and laterally compresses at it, moving toward a passive direction and returning to the initial position. The seismic earth pressure distribution shows a half-diamond distribution in the dense sand and a uniform distribution in loose sand. The loading point of dynamic thrust corresponding with seismic earth pressure is at the center of the soil backfill. The dynamic thrust increased differently depending on the backfill's relative density and input motion type. Still, in general, the dynamic thrust increased rapidly when the maximum horizontal displacement of the wall exceeded 0.05 H%.
        4,000원
        2.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In piping systems, trapeze hangers are subjected to vertical and horizontal seismic loads and stiffeners are used. In this study, monotonic compression tests were conducted with the removable stiffeners using three variables: stiffener clamp fixing position, section length, and installation direction. The maximum load reinforced with stiffeners could withstand a compressive load of 11kN by applying a safety factor of 10%. It could be estimated that the fixing clamp spacing or the length of shape and load had a proportional relationship. And the stiffener must be fixed in the direction of the strong axis on hinge parts. Also the stiffener buckiling load design proposes to use a method of calculate the flexural buckling compressive strength of and unreinforced full threaded bolt.
        4,000원
        3.
        2023.05 구독 인증기관·개인회원 무료
        Currently, in the United States, Spent Nuclear Fuel (SNF) is stored at the Independent Spent Fuel Storage Installations (ISFSIs) at 73 Nuclear Power Plants (NPPs). The SNF inventory stored on-site either in pools or dry storage was 84,500 MTU in 2020. The inventory stored in on-site dry storage facilities was 39,207 MTU (46% of the total), and it is growing at a rate of approximately 3,500 MTUs per year. However, because a site for geologic repository for permanent disposal of SNF has not been constructed in the U.S., the SNF will need to be stored in dry storage facilities across the U.S. for a much longer period of time than originally planned. During this time, the dry storage facilities could experience earthquakes of a different magnitude than the one for which they were originally designed. However, there is little data on the response of SNF inside dry storage systems to seismic loads in the U.S., and the various gaps and nonlinearities between storage containers, canisters, baskets, aggregates, and fuel make it very difficult to evaluate by analytical methods. Therefore, a full-scale shake table test is being planned as an international joint research project led by Sandia National Laboratories (SNL) in the U.S. In Korea, KNF decided to participate in this seismic test through the project of SNF integrity evaluation under road and sea normal transportation conditions organized by KNF and conducted by KORAD, KAERI, and Kyung-Hee University, and has provided the KNF 17ACE7 and PLUS7 test assemblies for the tests to SNL. The test will be conducted at the LHPOST6 shake table test facility operated by University of California in San Diego (UCSD) from 2023 to 2024, with the participation of KNF, CRI, and KAERI in Korea. The test units consist of a NUHOMS 32 PTH2 canister, a mockup of a generic vertical cask, a mockup of a generic horizontal storage module, 4 surrogate fuel assemblies, and 28 dummy assemblies. The seismic inputs for the tests will consist of ground motions (acceleration time histories) representative of hard rock, soft rock, and soil sites and seismic conditions in moderately tectonically active Central and Eastern US and highly tectonically active Western US. Ground accelerations for soft rock and soil conditions will be developed taking in account soil-structure interaction. Not only is this test almost impossible to conduct independently in Korea in terms of scale, facilities and costs, but it is also considered an essential test for those of us who are preparing for dry storage of spent nuclear fuel, given the increasing social concern about earthquakes due to the recent earthquake in Turkey.
        5.
        2013.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, an externally reinforced structural system for SMC(Sheet Molding Compound) panel water tank, designed according to the Japanese design code, is experimented to evaluate its seismic performance. The test tank is 3m long, 2m wide and 3m high, considering the capacity and size of the shaking table. The measured hydrodynamic pressures are found to be approximately 70% of the Japanese design code values. It may be partially due to the convex shape effect of the unit panels. The analytical results of externally reinforced system based on the measured dynamic water pressures are found in good agreement with the test results. If the design hydrodynamic pressures are estimated properly, the proposed analytical model for the externally reinforced water tank becomes a useful design tool and the Japanese design code is found to provide a safe design for the external frames of SMC panel water tank.
        4,000원
        6.
        2012.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 진동대 실험을 통한 수계형 소화설비의 내진성능평가를 실시하였다. 실험에 사용된 수계형 소화설비 시설에는 일반 배관, 내진형 배관, 펌프 등 이다. 그리고 수계형 소화설비 시설의 동적거통특성을 파악하기 위하여 El-Centro 지진파 50%,70%, 100%, 120% 수준의 가진을 가하였다. 그 결과, 내진형 설비보다 일반형 설비에서 변위 응답과 가속도 응답이 큰 것으로 보아내진형 설비가 일반설비에 비해 내진성능이 우수하다는 것을 알 수 있었다. 또한, 가진 수준별 가속도 응답스펙트럼을 통하여 일반형시설과 내진형 시설의 성능 평가뿐만 아니라 작은 규모의 지진에서도 일반형 설비의 파괴가 일어날 수 있다는 것을 알 수 있었다. 본연구를 통해 수계 소화설비의 내진성능을 평가 할 수 있었고 수계 소화설비의 내진성능 기준을 검증할 수 있었다.
        4,000원
        7.
        2010.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        원자력발전소에 설치되는 주요 전기기기들의 내부 부품을 내진검증하기 위해서는 캐비닛내부응답스펙트럼이 필요하고, 이는 캐비닛의 각 위치에서 정확한 지진응답을 구한 후에 생성이 가능하다. 반면에 대부분의 전기기기는 질량과 강성 분포가 복잡하기 때문에 해석적 방법에 의해 동적 분석을 수행하는 것이 어렵다. 이러한 여건을 감안하여 이 연구에서는 해석과 시험을 조합하여 기기의 지진응답을 예측하는 간편한 절차를 제안하였다. 제안된 절차는 먼저 충격시험을 통하여 규명된 실험모드특성을 이용하여 독립된 모드방정식을 구성하고, 이로부터 모드응답을 계산한 다음, 각 모드응답을 중첩함으로써 구조물의 지진응답을 예측한다. 제안된 절차의 신뢰성을 검증하기 위해서, 별도로 제작된 단순 강재 프레임 시편에 제안된 절차를 적용하여 지진응답을 예측하고, 이를 실제 진동대시험을 통하여 계측한 결과와 비교하였다. 이 연구를 통하여 충격시험에 의해 얻어진 실험모드특성을 이용하여 구조물의 지진응답을 비교적 정확하게 예측할 수 있음을 확인하였다.
        4,000원
        8.
        2008.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 원자력발전소에 설치되는 캐비닛형 전기기기의 동적 진동시험 자료를 이용하여 캐비닛의 지진응답을 예측할 수 있는 기법을 제안하였다. 제안된 기법은 1) 절점질량 이상화 모델에 기반한 등가 지진하중 산정, 2) 진동시험자료에 기반한 캐비닛 구조의 입출력 상태방정식 규명, 3) 산정된 등가지진하중과 규명된 입출력 상태방정식을 사용한 지진응답산정의 과정으로 구성된다. 제안된 기법은 유한요소기법(FEM) 모델 개선(Model Updating)에 기반한 지진응답예측기법에 비하여 모델링 오차가 개입 되지 않는 장점을 가진다. 캐비넷 구조를 이상화한 2차원 프레임 모델과 3차원 상세 모델에 대한 수치검증을 통하여 제안된 기법이 지진응답을 매우 정확하게 예측을 함을 관찰하였고, 측정 노이즈에 대해서도 강인함을 관찰하였다. 추후연구로 실험검증이 요구된다.
        4,000원
        9.
        2007.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구의 목적은 진동대 실험을 통한 철근콘크리트 교각의 지진거동을 파악하는데 있다. 사용된 프로그램은 철근콘크리트 구조물의 해석을 위한 RCAHEST이다. 재료적 비선형성에 대해서는 균열콘크리트에 대한 인장, 압축, 전단모델과 콘크리트 속에 있는 철근모델을 조합하여 고려하였다. 동적 평형방정식의 해는 HHT 법에 의한 수치적분으로 구하였다. 이 연구에서는 진동대 실험을 통한 철근콘트리트 교각의 지진거동을 파악하기 위해 제안한 해석기법을 신뢰성 있는 실험결과와 비교하여 그 타당성을 검증하였다.
        4,200원
        10.
        1999.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 철도, 도시고속화도로 및 고속도로 교량의 교각으로 많이 이용디고 있는 철근콘크리트 기둥으 내진성능 평가에 관한 quasi-static 실험으로서 사용된 실험 변수는 축하중 내진설계유무에 따른 띠철근량 변위제어 하중형태 등을 채택하였다 RC 기둥시험체는 수원에 위치한 하갈교의 교각을 1/3.4의 축소모델로 하여 내진설계된 단면과 내진설계되지 않은 시험체를 각각 4개씩 총 8개를 제작하였으며 소성힌지구간에서 띠철근의 간격은 2.2cm 및 4.4cm 이다 실험변수에 따른 내진 및 비내진 시험체의 내진성능검토를 위하여 충진콘크리트 교각의 하중변위 이력특성 연성능력, 강도감소, 에너지 흡수능력, 등가점성계수 등을 실험적으로 분석조사하였다. '96년 개정된 도로교시방서의 RC기둥에 관한 내진설계기준은 AASHTO(1992)와 유사한 것으로서 중.약지진 지역으로 구분되는 국내의 실정에는 다소 과다설계로 판단된다. 실험결과 비내진설계된 콘크리트 교각도 어느 정도의 연성능력을 발휘한 것으로 조사되었으나 추가의 충분한 실험연구가 요구된다. 그러나 비내진설계교각도 적절한 내진보강방안을 강구한다면 우수한 내진성능을 발휘할수 있으리라판단된다.
        4,300원
        11.
        2017.09 서비스 종료(열람 제한)
        In this study, the shake table tests were performed for seismic performance evaluation of fire protection riser pipes. The specimen was subjected to a tri-axial time history shake table test with acceleration levels corresponding to the 0.5g and 0.7g ZPA design level.
        12.
        2014.02 서비스 종료(열람 제한)
        지진 피해 상황을 살펴보면 중소 규모의 지진이 발생하였을 때 구조물의 붕괴에 의한 직접적인 피해가 아닌 화재와 같이 소화 설비, 전력설비, 통신설비 등 주요 기간설비의 기능상실로 인한 피해가 많이 일어나고 있다. 이와 같은 2차 피해를 줄이기 위해 소화설비의 내진설계는 반드시 필요하다고 할 수 있다. 본 연구에서는 수계소화설비의 내진성능 평가를 위하여 골조 구조물에 옥내소화전설비(배관, 펌프, 수조, 소화전)를 설치하여 진동대 실험을 실시하였다. 그리고 일반시설물과 내진시설물의 거동차이를 확인하기 위하여 각 설비는 기존 건축물에 시공되어 온 일반형 시설물과 내진형 시설물을 동시에 시공하여 시험을 수행하였다. 또한, 시설물의 거동특성을 파악하기 위하여 시설별 변위응답, 가속도 응답, 가속도 응답 스펙트럼을 분석하여 시설물에 대한 내진성능을 평가하였다.