검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2023.05 구독 인증기관·개인회원 무료
        Some of the metal waste generated from KEPCO NF is being disposed of in the form of ingots. An ingot is a metal that is melted once and then poured into a mold to harden, and it is characterized by a uniform distribution of radioactive material. When measuring the uranium radioactivity in metal ingot with HPGe detector, 185.7 keV of U-235 is used typically because most gamma rays emitted at U-235 are distributed in low-energy regions below 200 keV. To analyze radioactivity concentration of U-235 with HPGe detector more accurately, self-attenuation due to geometrical differences between the calibration source and the sample must be corrected. In this study, the MCNP code was used to simulate the HPGe gamma spectroscopy system, and various processes were performed to prove the correlation with the actual values. First an metal ingottype standard source was manufactured for efficiency calibration, and the GEB coefficient was derived using Origin program. And through the comparison of actual measurements and simulations, the thickness of the detector’s dead layers were defined in all directions of Ge crystal. Additionally instead of making an metal ingot-type standard source every time, we analyzed the measurement tendency between commercially available HPGe calibration source (Marinelli beaker type) and the sample (metal ingot type), and derived the correction factor for geometry differences. Lastly the correction factor was taken into consideration when obtaining the uranium radioactivity concentration in the metal ingot with HPGe gamma spectroscopy. In conclusion, the U-235 radioactivity in metal ingot was underestimated about 25% of content due to the self-attenuation. Therefore it is reasonable to reflect this correction factor in the calculation of U-235 radioactivity concentration.
        2.
        2022.10 구독 인증기관·개인회원 무료
        In gamma-ray spectrometry for volume samples, the self-attenuation effect should be considered in the case of differences in chemical composition and density between the efficiency calibration source for quantitative analysis of sample and the sample actually measured. In particular, the lower the gamma-ray energy, the greater the gamma-ray attenuation due to the self-attenuation effect of the sample. So, the attenuation effect of low-energy gamma-rays in the sample should be corrected to avoid over- or under-estimation of its radioactivity. One of the most important factors in correcting the self-attenuation effect of the sample is the linear attenuation coefficient for the sample, which can be directly calculated using a collimator. The larger the size of the collimator, the more advantageous it is to calculate the linear attenuation coefficient of the sample, but excessive size may limit the use of the collimator in a typical environmental laboratory due to its heavy weight. Therefore, it is necessary to optimize the collimator size and structure according to the measurement environment and purpose. This study is to optimize a collimator that can determine the effective linear attenuation coefficient of low-energy gamma-rays, and verify its applicability. The overall structure of the designed collimator was optimized for gamma-ray energy of less than 100 keV and cylindrical plastic bottle with diameter of 60 mm and a height of 40 mm. The materials of optimized collimator consisted of tungsten. Acryl and acetal were used to form the housing of the collimator, which fixes the central axis of the bottle, collimator and point-like source. In addition, using the housing, the height of the tungsten is adjusted according to the height of the sample. For applicability evaluation of the optimized collimator, IAEA reference material in solid form were used. The sample was filled in the bottle with heights of 1, 2, 3 and 4 cm respectively. Using the collimator and point-like source of 210Pb (46.5 keV), 241Am (59.5 keV), and 57Co (121.1 keV), the linear attenuation coefficient and the radioactivity for the samples were calculated. As a result, to calculate the linear attenuation coefficient using the optimized collimator, a relatively high sample height is required. However, the optimized collimator can be used to determine the linear attenuation coefficients of low-energy gamma-rays for the self-attenuation correction regardless of the sample height. It is concluded that the optimized collimator can be useful to correct the sample selfattenuation effect.