        This study performed the seismic response analysis of an LNG storage tank supported by a disconnected piled raft foundation (DPRF) with a load transfer platform (LTP). For this purpose, a precise analytical model with simultaneous consideration of Fluid-Structure Interaction (FSI) and Soil-Structure Interaction (SSI) was used. The effect of the LTP characteristics (thickness, stiffness) of the DPRF system on the seismic response of the superstructure (inner and outer tanks) and piles was analyzed. The analytical results were compared with the response of the piled raft foundation (PRF) system. The following conclusions can be drawn from the numerical results: (1) The DPRF system has a smaller bending moment and axial force at the head of the pile than the PRF system, even if the thickness and stiffness of the LTP change; (2) The DPRF system has a slight stiffness of the LTP and the superstructure member force can increase with increasing thickness. This is because as the stiffness of the LTP decreases and the thickness increases, the natural frequency of the LTP becomes closer to the natural frequency of the superstructure, which may affect the response of the superstructure. Therefore, when applying the DPRF system, it is recommended that the sensitivity analysis of the seismic response to the thickness and stiffness of the LTP must be performed.
        4,300원
        8.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        유연한 지반에 놓인 액체저장탱크의 지진 거동은 유체-구조물-지반 상호작용에 의해 복잡하게 나타나므로, 이 시스템의 지진응답 과 피해를 정확하게 예측하기 위해서는 이를 엄밀히 고려하여야 한다. 이 연구에서는 유체-구조물-지반 상호작용을 엄밀히 고려하여 유연한 지반에 놓인 직사각형 액체저장탱크의 지진응답 해석을 수행하고 그 응답 특성을 분석하고자 한다. 이를 위해 지진하중 작용 시 발생하는 유체의 동수압력 및 지반과 구조물 간의 상호작용력을 유한요소 기법을 사용하여 산정한다. 이때, 반무한 지반에서의 에너지 방사를 고려하기 위해 mid-point integrated finite element와 점성 감쇠기를 사용하여 지반 원역의 거동을 모사한다. 이와 같이 산정된 동수압력과 지반-구조물 상호작용력을 구조물의 유한요소에 작용시킨다. 자유장 해석을 통하여 입사 지진파에 의한 유효 지진력을 산정한다. 유연한 지반에 놓인 직사각형 액체저장탱크의 지진응답 해석을 통하여 지반-구조물 상호작용의 효과로 인해 시스템 응답의 변화가 다양하게 나타남을 확인할 수 있다. 그러므로, 유연한 지반에 놓인 직사각형 액체저장탱크의 내진설계를 수행하거나 내진성능을 검토할 때는 유체-구조물-지반 상호작용을 엄밀히 고려하여야 할 것이다.
        4,000원
        9.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 논문에서는 수직방향 지진입력에 의한 지반-구조물 상호작용 효과가 기초 종류에 따라 LNG 저장탱크의 지진응답에 미치는 효과를 분석하였다. 이를 위하여 직경 71m인 LNG 탱크와 기반암 위 점토지반의 깊이가 30m인 지반조건을 고려하였다. 그리고 기초형식으로 네 가지(얕은 기초, 말뚝지지 전면기초, 말뚝기초(지표면 접촉식, 부유식)를 고려하였다. 지반의 비선형성은 자유장 지반에 대하여 등가선형화기법으로 고려되었다. 또한, 말뚝기초의 시공과정에서 발생하는 동다짐 효과에 대해서도 분석하였다. SSI 해석을 위하여 진동수영역 해석프로그램인 KIESSI-3D를 이용하였다. 지반-구조물 상호작용 해 석을 통해 LNG 저장탱크의 외조 벽체 쉘의 응력을 구하였다. 해석결과로부터 다음과 같은 결론을 얻을 수 있었다: (1) 얕은 기초에서 외조탱크의 수직응력은 SSI 효과로 인하여 고정기초응답 보다 작았다. (2) 말뚝으로 지지된 기초에서 말뚝으로 인해 기초의 수직강성이 커지고 방사감쇠가 작아질 수 있기 때문에 SSI 응답이 고정기초응답 보다 커질 수 있다. (3) 동다짐 효과는 수직지진에 의한 LNG 저장탱크의 응답에 미치는 영향이 매우 작았다.
        4,000원
        12.
        2019.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        If sewage flows for an extended time at low velocities, solids may be deposited in the sewer. Sufficient velocity or tractive force should be developed regularly to flush out any solids that may have been deposited during low flow periods. This study aims to evaluate the periods (T) during which sewage flow greater than the minimum tractive force maintains on a spot in sewer pipe system with lower tractive force or lower velocity than expected in the design step, when a storage tank installed in a place upsteam pours water into the sewer. The effect to T of design factors of storage tank and sewer pipes was evaluated assuming the uniform flow in sewers. When the area of orifice in the storage tank is 0.062 ㎡(or 0.28 m diameter), the maximum T of 31sec was maintained using the usually used preset range of values of several design factors. As the horizontal cross section of storage tank and water depth of storage tank and roughness in sewers increase, T linearly increases. Also, T linearly decreases as the diameter of a sewer pipe increases. Although T gradually decreases as the sewer pipe slope decreases to around 0.005, T decreases sharply when the slope is less than 0.003.
        4,000원
        13.
        2018.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study examines earthquake-induced sloshing effects on liquid storage tanks using computation fluid dynamics. To achieve this goal, this study selects an existing square steel tank tested by Seismic Simulation Test Center at Pusan National University as a case study. The model validation was firstly performed through the comparison of shaking table test data and simulated results for the water tank subjected to a harmonic excitation. For a realistic estimation of the wall pressure response of the water tank, three recorded earthquakes with similar peak ground acceleration are applied:1940 El Centro earthquake, 2016 Gyeongju earthquake, and 2017 Pohang earthquake. Wall pressures monitored during the dynamic analyses are examined and compared for different earthquake motions and monitoring points, using power spectrum density. Finally, the maximum dynamic pressure for three earthquakes is compared with the design pressure calculated from a seismic design code. Results indicated that the maximum pressure from the El Centro earthquake exceeds the design pressure although its peak ground acceleration is less than 0.4 g, which is the design acceleration. On the other hand, the maximum pressure due to two Korean earthquakes does not reach the design pressure. Thus, engineers should not consider only the peak ground acceleration when determining the design pressure of water tanks.
        4,000원
        14.
        2017.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Liquid storage tank is one of the major infrastructures and generally used to store gases, drinking and utilizing water, dangerous fluids, fire water and so on. According to the recent reports and experiences, the tank structures are damaged in many earthquakes due to their low energy dissipating capacity. Therefore, many researchers have been tried to know the dynamic properties of the tanks including liquids. However, vary limited experimental studies are carried out using relatively small tank models. In this study, a series of shaking table tests are performed with maximum 2 m cubic rectangular liquid storage tanks made of steel to measure the natural frequency and estimate damping coefficient of impulsive and convective mode of the tanks. Especially, the damping values under different shapes and excitation methods are estimated by logarithmic decrement method and half power band-pass method and compared with current design code and standards such as ASCE 7, Eurocode 8 and NZS. Test results show that the impulsive mode damping is around 2% which is proposed by general standards and codes but the impulsive mode damping is 0.13% average that is slightly lower than the code recommendation.
        4,000원
        15.
        2016.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        플랜트의 유황 저장 탱크는 강재로 구성되며, 탱크 저면은 앵커볼트에 의해 Ring Wall 형상의 콘크리트 기초와 연결된다. 탱크 내 유황이 내부 열원에 의해 고온상태를 유지하기 때문에, 유황 저장 탱크는 상온의 유체를 저장하는 다른 탱크에 비해 큰 체적팽창을 겪게 된다. 일반적으로 탱크 기초의 구조설계는 기초의 내외부의 온도차를 하중으로 적용한 구조해석이 수행 되는데, 이 방법은 탱크의 열팽창 특성이 앵커볼트에 의해 집중하중 형태로 콘크리트 기초에 전달되는 현상을 고려할 수 없 다. 이는 온도하중의 영향을 과소평가하게 되며, 앵커볼트에 인접한 콘크리트의 균열을 야기한다. 본 연구는 앵커볼트에 의 한 온도 하중전달 메커니즘을 고려한 하중 평가식을 제안함으로써, 콘크리트 기초에 작용하는 하중을 보다 합리적으로 결정 하고자 한다. 이를 위해 탱크 바닥판과 앵커볼트가 포함된 유한요소모델을 이용해 앵커볼트 개수 증감에 따른 온도하중의 변화를 분석하였으며, 분석결과를 이론해와 결합해 앵커볼트에 의해 전달되는 하중을 평가할 수 있는 명시적인 형태로 해를 제시하였다. 제안된 식의 유효성을 확인하기 위해 실제 플랜트 현장의 유황 저장 탱크 설계에 적용하였으며, 실무적으로 사 용 가능함을 보였다.
        4,000원
        16.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The study on ice thermal storage system is to improve total system performance in actual air-conditioning facilities. To obtain the high charging and discharging efficiency in ice thermal storage system, the improvement of thermal stratification is essential, therefore the process flow must be piston flow in the cylindrical type. In the charging process, in case of inlet flow rate the thermal stratification has a tendency to be improved with the lower flow rate and smaller temperature gradient. The experimental results are as follows. (1) In case of Thermal storage, the stable stratification is formed with 2LPM and 4LPM after τ=0.5 and the temperature of inlet brine rises. therefore because of the heat conduction effect of Ice Ball and delay of inflowing water mixing, the heat flow keeps stably till τ=1.5. (2) In case that the flow directions inside the thermal storage tank are the upward flow in charging and the downward in discharging, thermal stratification is improved because the thermocline thickness is maintained thin and the degree of stratification increases respectively.
        4,000원
        17.
        2015.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The study on ice thermal storage system is to improve total system performance in actual air-conditioning facilities. This paper deals with experimental research to observe the characteristics of heat flow and the effect of ice thermal storage in case of three sizes of ice ball, which are included identification of ice thermal extraction. Diameters of three ice ball was 103mm, 96mm, and 76mm is equivalent to 0.45, 0.50 and 0.55 in porosity respectively. Also inlet geometric parameters are the perforator and distributor. Flow rate of brine were 2LPM, 4LPM and 6LPM and the temperature difference in dynamic parameter are 8℃, 10℃ and 12℃. Flow rate of brine used the liter per minute(LPM) for liquid measurement applications. The effect of brine flow rate on efficiency increased as the temperature difference and porosity increased. An adaption of a long-term storage in case of smaller porosity(ɛ=0.45) was available through experiments of outlet temperature responses.
        4,000원
        18.
        2014.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A 2D axisymmetric numerical analysis was performed to study the characteristics of charge process inside solar thermal storage tank. The porosity and heat transfer coefficient of filler material as well as inlet velocity of heat transfer fluid are selected as simulation parameters. The porosity is varied as 0.2, 0.5, and 0.8 to account for the effect of filler granule geometry. Two levels of the heat transfer coefficient is adopted to assess the heat transfer between heat transfer fluid and filler material. The inlet velocity is varied as 0.00278, 0.0278, and 0.278m/s. As both of the porosity and the heat transfer coefficient increase, the discrepancy of the temperature distributions between the filler and heat transfer fluid decreases. As the inlet velocity increases, the penetration depth of the heat transfer fluid increases proportionally.
        4,000원
        19.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A 2D axisymmetric numerical analysis was performed to study the characteristics of charge process inside solar thermal storage tank. The interfacial area density and inertial resistance of filler material are selected as simulation parameters. The interfacial area density is varied as 800, 2000, and 4000 1/m. The inertial resistance is varied as 1, 3, and 5 1/m. When the interfacial area density increases from 800 to 4000 1/m, the discrepancy of the temperature distributions between the filler and heat transfer fluid decreases. As inertial resistance increases from 1 to 5, both of the temperature and fluid flow pattern changes considerably.
        4,000원
        20.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 화석에너지의 남용으로 인한 지구온난화문제가 인류가 해결해야 할 지상과제로 대두되고 있으며, 본 연구는 이러한 에너지문제의 해결에 도움이 될 수 있는 고온축열탱크의 개발과 그 성능특성에 관한 내용이다. 지금까지 이에 관한 연구는 그다지 활발하지 않았으며, 특히 고온축열탱크에 관한 연구는 매우 드문 실정이다. 본 연구의 목적은 비교적 열물성이 양호하며 가격이 저렴한 물질인 MgO를 현열축열재로 사용하는 고온축열탱크의 개발이다. 이를 위하여 분말 상태의 MgO를 이용하여 축열벽돌을 제작하고, 실험적 방법을 통하여 MgO를 축열재로 사용하는 고온축열탱크의 성능특성에 관하여 연구하였다. 본 연구를 통하여 현열축열재인 MgO의 고온축열 및 방열성능을 확인하였다.