검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 4

        1.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the types of thermal breakers applied to structures to prevent thermal bridges were identified. Condensation prevention performance was evaluated for apartment houses with standard floor structures to which a thermal breaker was applied. In addition, the effect of thermal cross-blocking was compared by calculating the total heat and equivalent U-value through the wall. (1) As a result of the evaluation of anti-condensation performance, when “가” grade insulation was applied, the surface temperature increased by about 1K due to the application of the thermal breaker. The TDR value increased by about 0.06 to 0.07. When "나" grade insulation was applied, the minimum surface temperature increased by about 1K, and the TDR value increased by about 0.05~0.06. (2) As a result of the evaluation of total heat and U-equivalent, it was possible to reduce the total heat by 38.5~44.9% and U-equivalent by 38.5~45.0% for the "가" grade insulation to which the thermal breaker was applied. In addition, the "나" grade insulation to which the thermal breaker was applied can reduce total heat by 38.9 to 43.6%, and reduce the Uequivalent by 38.9 to 43.7%.
        4,000원
        2.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        of the marketed multi-later insulating curtain was carried out. Experiments is conducted by fabricating a test apparatus for investigating the heat flux characteristics. The multi-later insulating curtain used for the experiment was compared using the P, N, S, U and T company, which are commercially available, and the heat flux due to temperature difference between the experimental apparatus and the outside was compared and analyzed. When the internal temperature of the experimental result is the maximum temperature 60℃, the heat flux of multi-later insulating curtain is T Co.(73.1W/m2) > S Co.(119.5W/m2) > U Co.(155W/m2) > N Co.(163.1 W/m2) > P Co.(177.7W/m2). The heat flux means the quantity of heat passing through the unit time per unit area, and the higher the numerical value, the higher the quantity of heat passing through the multi-layer insulating curtain. This can be determined that high heat fluxes produce low heat resistance. Further, it has been found that the weight of the insulating curtain is largely unrelated to the heat insulating property, and the heat insulating curtain having a thickness containing a high internal air layer is excellent in the heat insulating property. In the future when manufacturing a heat insulating curtain, It is judged that it is desirable to manufacture a combination of heat insulating materials that contain a high internal air layer content and that can maintain the air layer even for long-term use while minimizing the volume.
        4,000원
        3.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, thermal performance test of VMD module was performed, prior to the construction of the demonstration plant using the vacuum membrane distillation (VMD) module of the capacity of 400 m3/day and to the commercialization of the VMD module. For the thermal performance test, the experimental equipment of capacity of 2 m3/day was constructed. The permeate flux test and thermal performance test according to feed water conditions such as temperature and flow rate were conducted. The VMD module used in the study was manufactured by ECONITY Co., LTD with PVDF hollow fiber membrane. As a result, the Performance Ratio (PR) of the VMD module showed the maximum value of 0.904 under the condition of feed water temperature of 75℃ and flow rate of 8 m3/h. PR value of the VMD module using PVDF hollow fiber membrane showed linearly increasing relationship with feed water temperature and flow rate. Also, The permeate flux of the VMD module was analyzed to have maximum value of 18.25 LMH and the salt rejection was 99.99%.
        4,000원
        4.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyzed indoor and outdoor thermal performance among different types of green roofs and green walls in order to provide information for building greening. When temperature reduction effects of green roofs and green walls were compared to the control, the effects was highest at the green roof and wall treatment, followed by green wall, green roof, and the control, which means there was temperature reduction effects by building greening. Also these temperature reduction effects was influenced by outdoor weather condition such as being typically high in sunny days but not notable in rainy days. In addition temperature reduction was effective as the air temperature was up but was not influenced by wind velocity. As for directions, the west side showed the highest temperature followed by the south and east in the order. Heat flow was found greater in control than in green roof and green wall. In addition, heat flow reversal was found as time went on.
        4,000원