검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 268

        1.
        2024.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study improved the work efficiency by supplementing the shortcomings of the manual process by developing a double tube feeding device, and the following results were obtained by conducting the production capacity, production length, and defect rate tests. Developed a double tube production system to enable the simultaneous production of two tubes, increasing the production volume by about 1.5 times. The product length has been improved from semi-automatic to automated, and the production capacity has been improved from 16 to 25 pieces per hour (based on 15m). Developed a double-tube input straight line automatic adjustment feeder, which resulted in reducing the defect rate to less than 1%.
        4,000원
        2.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, Pleurotus ostreatus No.42 was cultured in glucose-peptone-yeast-wheat bran medium using a previously reported novel rotary draft tube bioreactor. Versatile peroxidase (VP), a lignin-degrading enzyme, was isolated from a pellet-type mycelium culture grown in the medium for seven days. The VP was purified by sequentially applying ultra-filtration, DEAESepharose CL-6B column, and Mono Q column. SDS-PAGE analysis revealed the molecular weight of VP to be 36.4 KDa with an isoelectric point of 3.65. The amino acid sequence was confirmed as VTCATGQTT. The purified VP was observed to possess the property of not only oxidizing Mn ions but also decomposing veratryl alcohol, a non-phenolic compound. The catalytic ability of VP is a subject for future research.
        4,000원
        3.
        2023.11 구독 인증기관·개인회원 무료
        Nuclear fuel assemblies are exposed to high temperature and high pressure environments underwater for long periods of time in a reactor, leading to deterioration of the assembly structure. These assembly consists of fuel rods, grids, a top nozzle, a bottom nozzle and guide tubes. In particular, the integrity of the guide tube made of Zircaloy-4 is a very important part in handling the assembly. In the Post Irradiation Examination Facility (PIEF), there are 14×14 Westinghouse STD assemblies that have lost their handleability due to the top nozzle being removed for damaged fuel rod test. To handle these assemblies, it is reasonable to use cut guide tubes whenever possible. Therefore, it is necessary to determine the irradiation embrittlement state of the guide tube before designing or manufacturing parts that can connect the top nozzle and the guide tubes. Therefore, in this paper, the location for installing the top nozzle-guide tube connection parts was selected in the height range of 3,460 to 3,713 mm, and guide tube specimens were made within that range. Offset strain was derived from the load-displacement curve obtained through compression testing to confirm whether the ductility of guide tubes was maintained. As a result, there was no significant difference in strength and ductility of the guide tube within the above length range. In addition, it was confirmed that the ductility was maintained enough to install the top nozzle-guide tube connection parts. Therefore, it is judged that there will be no problem even if the top nozzle-guide tube connection parts are installed in the guide tube to restore the handleability of the assemblies.
        4.
        2023.11 구독 인증기관·개인회원 무료
        In general, systems are developed by repeatedly performing the processes of design, analysis, manufacturing, and performance testing. In particular, systems with temperature, pressure, and flow rate often utilize computational fluid dynamics tools at the design stage. In this paper, we aim to verify the reliability of the analysis results of Solidworks Flow Simulation, which is widely used in heat flow analysis at the design stage. A tube furnace was manufactured, various experiments were performed, and a study was conducted to compare the analysis results. The details of the experiment are as follows. First, an experiment was conducted in which the heater was heated to 900°C without insulating the exposed part of the tube. The detailed contents of the experiment are as follows; - Heating heater and measuring temperature without supplying flow inside the tube, - Tube flow supply (25°C, 15 lpm air) and heater heating/temperature measurement. Second, an experiment was performed in which the exposed part of the tube was insulated (thickness 50 mm) and the heater was heated to 900°C. The detailed contents of the experiment are as follows; - Insulate the outside of the tube except for the flanges at both ends of the tube, and heat the heater and measure the temperature without supplying flow inside the tube. - Insulate the outside of the tube except for the flanges at both ends of the tube, supply flow rate inside the tube (25°C, 15 lpm air) and measure heater heating/temperature. - Insulate the flange of the flow supply section, heat the heater and measure temperature without supplying flow inside the tube. - Insulate the flange of the flow supply section, heat the supply air (277°C, 15 lpm) and measure the temperature using a heating gun without heating the heater. - Insulate the flange of the flow supply section, supply heated air (277°C, 15 lpm) and measure heater heating/temperature. - Insulate the flange of the flow supply section and measure temperature according to heater heating (900°C) and supply temperature (25°C, 277°C 15 lpm). The following results were derived from the experimental and analysis results. - When the exposed part of the tube is insulated, the temperature inside the tube increases and the steady-state power decreases compared to non-insulated. - In areas with insulation, the temperature error between experiment and analysis results is not large. - When flow rate is supplied, there is a large temperature error in experiment and analysis results. - The temperature change after the center of the heater is not large for a temperature change of 15 lpm flow rate. From these results, it can be seen that Solidworks Flow Simulation has a significant difference from the experimental results when there is a flow rate in the tube. This was thought to be because the flow rate acts as a disturbance, and this cannot be sufficiently accounted for in the analysis. In the future, we plan to check whether there is a way to solve this problem.
        5.
        2023.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, the International Maritime Organization is strengthening regulations for ships operating in polar regions. Hence, insulated multi-core tubes as components for vessels operating in extreme cold need to be investigated in various aspects. Furthermore, the demand for research on electric propulsion vessels is also increasingly growing. Thus, to utilize a 4-core insulated multi-core tube with glass wool as insulation, which was previously developed for ships operating in polar regions, as a water-cooled electrical cable, this study conducted an experiment on the temperature change when water at normal temperature 25℃ was supplied as a coolant under the overcurrent varied from 10A to 25A. As a result, the temperature increase of the core in 10A condition was 3.3℃, but it increased to 13.05℃ in the 25A condition. This showed that a temperature difference of approximately 9.75℃ occurred according to the overcurrent load. However, the coolant inlet and outlet temperatures were relatively uniform around 1℃ in all conditions. This suggests that increasing the residence time by proper control of the coolant flow in the future could achieve a higher cooling effect.
        4,000원
        6.
        2023.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Although the proportion of coal-fired power generation is decreasing, efficient operating technology is needed to continuously invest in facilities and reduce maintenance costs until it is abolished. Boilers, one of the main facilities of power plants, operate for a long time in harsh environments of high temperature and high pressure. In addition, damage due to deterioration is likely to occur depending on the fuel and tube material used. It is very important to judge soundness because damage caused by deterioration adversely affects facility operation. Previously, replication method was used to analyze the progress of deterioration. In the replication method, pre-treatment such as chemical treatment is performed on the boiler tube in the field, the area is reproduced by attaching a film, and the replicated film is determined by an expert in the laboratory with an expensive microscope. However, this method involves substantial costs and time requirements, as well as the possibility of human errors. To address these issues, we developed a mobile health assessment system in this research. Since it is detachable and takes images in real time, this system enables swift evaluations across a broad range and facilitates the assessment of preprocessing quality. In addition, it was intended to reduce existing human mistakes by developing a degradation classification algorithm using the merger cluster method.
        4,000원
        7.
        2023.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Radiant tubes heat exchangers are critical components that facilitate the heat transfer process to steel in an annealing furnace, and it addresses several engineering problems, such as thermal stress and mechanical failure due to long-term thermal cycling, which can significantly affect the longevity of the tubes and maintenance requirements. In this study, we used commercial software (ANSYS) to simulate the thermal stress and deformation of radiant tubes subjected to extreme thermal conditions and pressure loads. We evaluated both thermally induced deformation and creep deformation, which is a time-dependent deformation under constant stress over the long term. The results showed that uneven temperature conditions and pressure loads lead to significant deformation and potential failures. To mitigate these engineering challenges, we also tested several designs that include supporting brackets. This study provides valuable insights for designing radiant tube heat exchangers in annealing furnaces to extend their lifespan and ensure system safety.
        4,000원
        8.
        2023.05 구독 인증기관·개인회원 무료
        According to ISO 4037, the thickness of the inherent filtration for the radiation qualities L-40 to L- 240, N-40 to N-400, W-60 to W-300 and H-80 to H-400 shall be equivalent to 4 mm Al for matched reference radiation fields or adjusted as far as possible to 4 mm Al for characterized reference radiation fields. And for matched reference fields, the tube window must be made of beryllium and its thickness should not exceed 10 mm. In the case of characterized reference fields, the thickness of the beryllium window should not exceed 10 mm, but it is acceptable to use an aluminum window with a maximum thickness of 1.5 mm. 320 KV X-ray tube installed at KHNP-CRI has been designed to equipped with a 3 mm Be for tube window and an additional 4 mm Al to obtain a total inherent filtration equivalent to that of 4 mm Al. In the previous study, the inherent filtration of 320 kV X-ray tube at KHNP-CRI has been verified by MCNP simulation. However, the ISO standards suggest a method for determining the thickness of the inherent filtration by half-value layer (HVL) measurement and spectrometry. In this regard, the inherent filtration was reassessed using HVL measurement. To determine the inherent filtration, 1st HVL of the beam generated by the tube at a tube potential 60 kV was measured. The measurements were conducted with a calibrated spherical ionization chamber (model A3, Exradine) placed at a distance of 1 m from the target, at the center of the radiation field size. The X-ray tube current was set to 2 mA. The thickness of aluminum absorbers was gradually adjusted in subsequent measurements until approached the 1st HVL. 1st HVL were estimated using the linear regression equation computed with the current values for the thickness of the absorbers. As a results, the thickness of the 1st HVL was estimated as 2.845 mm Al. According to the correlation between the inherent filtration and 1st HVL suggested in ISO standard, the value of the inherent filtration was deduced as 4.25 mm Al that is rounded to the nearest 0.05 mm by interpolation. Further studies on the effects of the inherent filtration thickness determined in this study will be conducted.
        9.
        2023.05 구독 인증기관·개인회원 무료
        In this paper, a basic study was conducted to observe the temperature inside the tube according to the heating temperature of the tube furnace. In a tube furnace, a tube is inserted, and the air space outside the tube is heated to increase the temperature of the gas inside the tube through conduction of the tube. Tube furnaces are widely used in research to capture volatile nuclides. In this case, a volatile nuclide capturing filter is inserted inside the tube, and an appropriate temperature is required to capture it. Since the tube furnace heats the air space outside the tube to the target temperature, a difference from the temperature inside the tube occurs. In particular, if a flow of gas occurs inside the tube, a larger temperature difference may occur. In order to confirm this temperature difference, an experimental device was constructed, and basic data was produced through several experiments. The following studies were conducted to produce data. First, the temperature of the air layer of the heating unit and the temperature inside the tube were measured in real time in the absence of gas flow inside the tube. Second, the temperature of the air layer of the heating unit and the temperature inside the tube were measured in real time while air having a certain temperature was flowing inside the tube. As a result of the experiment, when there is no flow inside the tube, when the heating target temperature is low, the temperature inside the tube is significantly lower than the target temperature, and when the target temperature is high, the temperature inside the tube approaches the target temperature. It was found that when there is about 20°C air flow inside the tube, the temperature inside the tube is significantly lowered even if the heating target temperature is high. In the future, additional research on changing the temperature of the gas flowing inside the tube will be conducted, and the results of this study are expected to greatly contribute to the design of a tube furnace that captures volatile nuclides.
        11.
        2023.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Due to its excellent processability, thermal conductivity and high corrosion resistance, copper tubes applied to heat exchangers are being joined through brazing to increase heat exchange efficiency. In order to improve performance, the issue of joint quality of copper tubes, a major member of heat exchangers, is emerging, so research is needed to obtain excellent joint quality of brazing joints that may be damaged. In this study, the quality change of joints according to process variables was studied through induction heating brazing experiments using high frequency. The depth of penetration, which indicates the quality of the junction, was measured, and the center position of the high-frequency electrode and the height of the electrode, which change the location of the heat source applied to the junction, were selected as process variables. Lastly, the thermal image data obtained between the brazing experiments were obtained and the joint quality according to the temperature gradient of the joint was analyzed.
        4,000원
        12.
        2023.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The shell & tube-type heat exchanger has been frequently used because it shows simple structure, easy manufacturing and wide operation conditions among many heat exchangers. This study aims to investigate the characteristics for thermal flow of coolant and the possibility of damage for tube equipped with shell due to thermal stress. For these purposes, The thermal flow of coolant in tube was simulated using ANSYS-CFX program and thus the behaviors of coolant were evaluated with standard k-ε turbulence model. As the results, as the flow rate of coolant in tube was increased, the mean relative pressure was also increased with quadratic curve, however, as the surface temperature of tube was increased, mean temperature difference was linearly increased. Finally it showed that the damage of tube could be predicted, that is, which tube was the most weak due to thermal stress.
        4,000원
        13.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        지난 10년간 선박의 횡동요 복원력 상실에 의한 해양사고가 지속해서 증가하고 있어, 횡동요 운동을 효과적으로 줄일 수 있는 장치가 필요한 실정이다. 횡동요 감쇄 탱크는 단순한 설치만으로 횡동요 저감을 가져오는 대표적인 수동형 제어장치로 그 장점이 널리 알려져 있다. 따라서 본 연구에서는 U-튜브형 횡동요 감쇄 탱크의 수치해석 기법을 개발하고자 한다. 특히, 해석기법의 검증을 위해 자유 수면 높이를 실험을 통해 계측하였다. 수치해석기법은 메쉬 의존성, 난류모델 ( ,  , Reynolds Stress Model), 시간 간격 크기 및 반복 횟수 등의 영향을 비교하여 개발하였다. 최종적으로 개발된 해석기법은 Realizable  이 난류 모델에 10-2s 수준의 시간 간격 크기와 15 회의 반복횟수를 적용하였다. 2가지의 U-튜브형 감쇄 탱크의 조건에서 계측된 자유수면 높이를 이용하여 개발된 해석기법을 검증하였다. 본 연구의 수치해석은 RANS 기반 상용 해석 Solver인 STAR-CCM+ (ver. 17.02)을 이용하였다.
        4,000원
        14.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        콘크리트 충전강관은 국부좌굴을 방지하고 내화성이 향상되기 때문에 건설현장에서 많이 적용되며 휨성능을 향상시 키기 위해 강관 내부에 철근을 보강하여 사용한다. 그러나 철근은 부식되며 내구성이 저하되기 때문에 이를 대신할 소재에 대 한 연구가 진행되고 있다. 탄소섬유보강근은 철근에 비해 경량이며 고강도와 내부식성이 우수하다는 이점이 있다. 그러나 임계 온도가 250℃로 철근의 임계온도인 538℃에 비해 현저히 낮기 때문에 내화피복이 필요하다. 따라서 열전달해석을 통해 탄소섬 유보강근을 사용하였을 때 온도분포를 확인하고 P-M상관도를 도출하여 적용 가능여부를 확인하고자 한다. 해석결과 내화성능을 확보하기 위해 콘크리트 피복두께 40mm, 뿜칠내화피복재 30mm를 적용하거나 콘크리트 피복두께 60mm, 뿜칠내화피복재 20mm 를 적용하면 3시간 내화성능을 만족하는 것으로 평가되었다.
        4,200원
        15.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the cooling performance change according to the arrangement of the fin-tube heat exchanger using a single tube and the cooling performance change according to the air flow rate were studied. The arrangement of basic heat exchanger was set to 4 columns and 4 rows, and the performance change was studied while changing the columns and rows. In addition, the performance change was investigated by changing the air flow rate of the basic heat exchanger.
        4,500원
        16.
        2022.08 구독 인증기관 무료, 개인회원 유료
        The restraints are used in the intensive care unit as a way to restrict the movement of the whole body or part of the body for the safety of the patient, such as maintaining medical equipment, preventing falls and patient self tube removal through regulating the patient's behavior. However, the physical restraints are used for the physical safety of the patient, but that is cause a variety of physical and psychological complications. Thus, nurses in intensive care units who apply restraint on face an ethical dilemma in the confrontation between the nurse's duty to improve the patient's health and protect the patient's safety and the value of the patient's autonomy and dignity. We have two examples are proposed to identify the ethical dilemma situation faced by nurses, to induce an active attitude towards elimination by establishing exactly restraint - removal criteria. In addition, it is proposed to seek a balance of individual values through active communication between the patient and the medical staff regarding the application of the restraint.
        4,000원
        17.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The use of heat exchangers in various applications such as chemical, air conditioning systems, fuel processing, and power industries is increasing. In order to improve the performance of the heat exchanger, the problem of bonding quality of the copper tube, which is a major member, is emerging. However, since the copper tube is in the form of a pipe, it is difficult to identify internal defects with external factors. In this study, a thermal imaging camera was used to develop and verify an algorithm for detecting defects in the brazing part, and in the process, the brazing performance characteristics were analyzed according to the electrode position, and finally, a learning model was developed and performance evaluation was performed. It was confirmed that the method of supplying heat to the base material and melting the filler metal through the heat transfer effect is more effective than supplying heat input to the filler metal in the bonding process of copper tubes through high-frequency induction heating brazing. Thermal image data was used to develop a defect discrimination model, and 80% of training data and 20% of test data were selected, and a neural network-based single-layer copper tube brazing defect discrimination model was developed through k-Flod cross-validation., the prediction accuracy of 95.2% was confirmed as a result of the error matrix analysis.
        4,000원
        18.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We investigated the electronic and mechanical properties of single-walled carbon nanotubes (SWCNTs) with different tube diameters using density functional theory (DFT) and molecular dynamics (MD) simulation, respectively. The carbon nanotubes’ electronic properties were derived from the index number ( n 1 , n 2 ), lattice vectors, and the rolled graphene sheet orientation. For (6,1) SWCNT, ( n 1-n 2)/3 is non-integer, so the expected characteristic is semiconducting. We have considered (6,1) Chiral SWCNT with different diameters ‘d’ (4.68 Å, 4.90 Å, 5.14 Å, 5.32 Å, 5.53 Å) corresponds to respective bond lengths ‘  ’ (1.32 Å, 1.38 Å, 1.45 Å, 1.50 Å and 1.56 Å) and then analyze the electronic properties from the Linear Combination of Atomic Orbitals (LCAO) based on DFT. We have used both the DFT-1/2 and GGA exchange energy correlation approximations for our calculation and compared the results. In both cases, the energy bandgap is decreasing order with the increase in bond lengths. The lowest value of formation energy was obtained at the bond length  = 1.45 Å ( d = 5.14 Å). For the mechanical properties, we have calculated Young’s modulus using molecular dynamics (MD) simulations. From our calculation, we have found that the (6,1) SWCNT with bond length 1.45 Å ( d = 5.14 Å) has Young’s modulus value of 1.553 TPa.
        4,000원
        19.
        2021.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        This paper aims to evaluate the mechanical integrity for Spent Nuclear Fuel (SNF) cladding under lateral loads during transportation. The evaluation process requires a conservative consideration of the degradation conditions of SNF cladding, especially the hydride effect, which reduces the ductility of the cladding. The dynamic forces occurring during the drop event are pinch force, axial force and bending moment. Among those forces, axial force and bending moment can induce transverse tearing of cladding. Our assessment of 14 × 14 PWR SNF was performed using finite element analysis considering SNF characteristics. We also considered the probabilistic procedures with a Monte Carlo method and a reliability evaluation. The evaluation results revealed that there was no probability of damage under normal conditions, and that under accident conditions the probability was small for transverse failure mode.
        4,200원
        20.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper considers the influence of internal heat exchanger and capillary tube on the efficiency of small refrigeration system using eco-friendly refrigerants such as R290, R600a, R1270, and R717. A refrigeration system using such internal heat exchanger and capillary tube may improve performance, but may degrade performance. Therefore, this paper used a mathematical model in a normal state to understand performance characteristics as to what change occurs when internal heat exchanger and capillary tube are attached to eco-friendly refrigerant based on R134a. In addition, the effects of operating conditions such as refrigerant flow rate, evaporation temperature, condensation temperature, subcooling degree internal heat exchanger length and capillary tube length were analyzed. The result showed that the evaporation temperature, condensation temperature, subcooling degree, internal heat exchanger length and capillary tube length had an effect on the refrigeration capacity and compression power. Therefore, it is necessary to design a refrigeration cycle using an eco-friendly refrigerant by grasping these effects in detail.
        4,000원
        1 2 3 4 5