검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 131

        41.
        2014.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        췌장 가성 낭종의 종격동 침범은 매우 드문 췌장염의 합병증이다. 췌장염 환자가 비전형적인 흉통이나, 호흡곤란, 삼킴곤란 등을 호소하면 이 질환을 의심해 봐야 한다. 종격동 췌장 가성 낭종은 심각한 합병증을 초래할 수 있으므로 빠른 진단과 적절한 처치가 중요하다. 비록 현재까지 제한적으로 시행된 시술이지만, 종격동 가성 낭종에서 초음파 내시경 유도 배액술은 기술적으로도 가능하고 외과 수술보다 덜 침습 적이며 효과적인 배액술이라 할 수 있다. 이러한 종격동 침범 가성 낭종의 치료를 위한 다양한 내시경 배액법의 효과와 안전성에 대한 추가적인 연구가 요구된다.
        4,000원
        42.
        2014.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aimed to investigate the association between carotid artery calcification (CAC) on panoramic radiograph and intima-media thickeness (IMT) measured on ultrasound. Panoramic radiographs which were taken from dental patients aged 50 years and older who visited for dental treatment were screened for the presence of CAC. The study group was composed of seven patients (four males and three females, average age 74.4±4.2 yrs) with CAC detected on panoramic radiographs, and the control group eleven patients (seven males and four females, average age 64.5±10.1 yrs) without CAC. All the patients underwent carotid ultrasonography to measure carotid IMT. The IMT was compared between the groups by nonparametric analysis of covariance (ANCOVA). The range of IMT of the study group was 1.10~2.0 mm, while that of the control group 0.60~1.10 mm. The mean of IMT was 1.50±0.34 mm in the study group and 0.85±0.14 mm in the control group, and there was statistically significant difference between the two groups (p<.01). In conclusion, CAC detected on panoramic radiograph might have an association with atherosclerosis
        4,000원
        43.
        2013.10 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        췌십이지장 동맥류는 드물고 진단에 특징적인 신체 진찰소견이 없어 초기 진단이 어렵다. 이전에는 대부분이 파열과 동시에 진단되었으나, 최근 영상 검사의 발달로 우연히 발견되는 경우가 증가하고 있다. 췌십이지장 동맥류는 대부분이 파열되며, 파열시에는 치사율이 50% 에 달해 정확한 진단에 따른 치료가 중요하다. 파열시에는 혈관 조영술이 진단과 치료를 위한 좋은 검사이나, 검진 상 발견되는 경우에는 췌장종괴와의 감별 위하여 내시경 초음파가 진단에 도움을 줄 수 있다. 저자들은 복부통증을 주소로 내원하여 췌십이지장 동맥류를 전산화 단층촬영과 내시경 초음파를 통해 파열 전 진단하고 경피적 동맥색전술로 후유증 없이 치료한 1 예를 경험하였기에 문헌고찰과 함께 보고하는 바이다.
        4,000원
        44.
        2013.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study examined differences in the activity of upper limb muscles according to how an ultrasound head is gripped. Twenty-two adult males were participated in the study. Each participant was asked to apply ultrasound treatment on to a lump of pork meat by two different ultrasound head grip patterns: spherical and cylindrical grips. Muscle activity was measured in the extensor carpi radialis longus (ECRL), flexor carpi ulnaris (FCU), and pronator teres (PT), triceps brachii (TB), middle deltoid (MD), and upper trapezius (UT) muscles. There were no significant differences in the EMG signals of any muscle according to the ultrasound head grip pattern (p>.05). There were significant differences in the EMG signal of each type of muscle (p<.05). The EMG signal of UT was the lowest and that of TB was lower than ECRL and FCU. There were interactions between ECRL and FCU, between ECRL and PT, between FCU and ECRL, and between FCU and MD. The EMG signal of ECRL using the cylindrical head was low and that of FCU with the cylindrical head was high, while the opposite was the case with the spherical head ( <.05/15). The results of this study indicate that the wrist muscles worked actively when the participants applied ultrasound therapy using both spherical and cylindrical heads. A spherical head might induce imbalanced muscle activity among the wrist muscles, leading to deviation of the wrist joint. Therefore, the cylindrical head is recommended for ultrasound therapy because it produced a constant, repeated force.
        4,000원
        45.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was performed to compared the effectiveness of individual treatments (electrolyzed water: EW, organic acid, and ultrasound) and their combination on reducing foodborne pathogens from perilla leaves. Perilla leaves were innoculated with a cocktail of Salmonella Typhimurium, Staphylococcus aureus, Bacillus cereus. Inoculated perilla leaves were treated with EW combined with different concentration of acetic acid (0.5%, 1.0%, 1.5%, 2.0%) for 1 min at room temperature. Treatment of 3 pathogens on perilla leaves with electrolyzed water combined with ultrasound (25 kHz) and 0.5% acetic acid was also performed for 1 min. While the numbers of S. Typhimurium and B. cereus showed reduced with increasing acetic acid concentration, there is no difference in the number of S. aureus treated with EW containing 0.5% to 1.5% acetic acid. Discoloration was observed the perilla leaves treated with EW combined with more than 1.0% acetic acid. For all three pathogens, the combined treatment of EW and ultrasound resulted in additional 0.42 to 0.72 log10 CFU/g. The maxium reductions of S. Typhimurium and B. cereus were 0.95, 1.23 log10 CFU/g after treatment with EW combined with 0.5% acetic acid and ultrasound simultaneously. The results suggest that the treatment of EW combined with 0.5% acetic acid and ultrasound increased pathogens reduction compared to individual treatment.
        4,000원
        46.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        일부 고주파 음파 처리가 파밤나방(Spodoptera exigua)의 생리변화를 유발시킨다. 이 연구는 초음파( 20 kHz) 처리가 파밤나방 유충 섭식, 용 발육 및 성충 교미행동에 미치는 영향을 분석하였다. 초음파 처리는 5령충의 섭식 활동을 억제시켰다. 특별히 30 kHz 또는 45 kHz 초음파 처리를 받은 유충은 50% 이상의 섭식활동이 감소하였다. 이러한 초음파 처리를 받은 유충은 혈장의 주요 영양물질 함량이 변동되었다. 혈장 단백질은 처리 초음파의 주파수 증가에 따라 감소하였다. 그러나 혈당은 처리 초음파의 주파수 증가에 따라 증가하였다. 지질 함량은 30 kHz 처리까지는 증가하다가 이후 감소하였다. 파밤나방 5령의 혈구, 지방체 및 표피세포의 세 조직은 스트레스 관련 유전자들인 세 종류의 열충격단백질과 apolipophorin III를 발현시켰다. 그러나 초음파를 처리할 경우 일부 스트레스 관련 유전자들의 발현을 크게 억제시켰다. 초음파 처리는 또한 용발육을 억제시켜, 용기간을 연장시키고 성충으로 우화를 현격하게 낮추었다. 끝으로 초음파 처리는 성충의 교미행동을 억제시켜 암컷의 산란력을 뚜렷하게 낮추었다. 이러한 결과는 초음파가 파밤나방의 생리적 스트레스로 작용하고 있다는 것을 제시하고 있다.
        4,000원
        47.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The lower trapezius muscle is an important stabilizer and primary mover of the scapula. The potential use of ultrasound imaging to evaluate scapular muscle function warrants investigation. The purpose of this study is to use ultrasound imaging for determining the effectiveness of 4 different isometric exercises for maximally activating the lower trapezius muscles in healthy subjects. Twenty-eight (14 men and 14 women) volunteers were recruited for this study. Thickness measurements of the lower trapezius muscles were recorded during 4 exercises: latissimus pulldown (LP), prone V-raise (PV), prone row (PR), and modified prone cobra (MP). Lower trapezius muscle thickness was measured 3 times by 2 investigators at a point 3 cm lateral to the lateral edge of the T8 spinous process. The order of 4 exercise execution was randomized for each participant. To identify statistical significance, one-way ANOVA with repeated measures was used with the significance level of .05. Intraclass correlation coefficient (ICC) for intra-reliability was .86~.98 and inter-rater reliability .83~.96 for the lower trapezius, respectively (p<.01). Thickness changes in the lower trapezius muscles between the relaxed and contracted states in men were as follows: LP (, 182%), MP (, 167%), PV (, 149%), and PR (, 133%). In women the values were as follows: LP (, 163%), MP (, 131%), PV (, 129%), and PR ( mm, 100%). Thickness of the lower trapezius muscles significantly differed between exercises in both the gender (p<.01). The LP was the most effective exercise for increasing the activation of the lower trapezius muscle in both the gender. We recommend performing the LP exercise for strengthening the lower trapezius muscles.
        4,000원
        48.
        2011.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to investigate intra-rater reliability and determine the validity of electromyography (EMG) measurements to represent muscle activity and ultrasonography (US) to represent muscle thickness during manual muscle testing (MMT) to external abdominal oblique (EO) and lumbar multifidus (MF). Twenty healthy subjects were recruited for this study and asked to perform MMT at differing levels. The subjects' muscle activity using EMG was measured by a ratio to maximum voluntary contraction (MVC) and root mean square (RMS) methods. The subjects' muscle thickness using US was measured by raw muscle thickness and change ratio of thickness to maximum (MVC) or resting condition. In three trials, measurements were performed on each subject by one examiner. The intra-rater reliability of measurements of EMG and US to EO and MF was calculated using intra-class coefficients. The intra-rater reliability of all measurements was excellent (ICC=.75~.98) in EMG and US. The conduct validity was calculated by one-way ANOVA with repeated measurements to compare whether the EMG and US measurements were different between MMT at different levels. There was only a significant difference between all grades at %MVC thickness measurement of US. These results suggest that a %MVC thickness measurement of US was a more sensitive and discriminate in all manual muscle testing grades. This information will be useful for the selection of US measurement and analysis methods in clinics.
        4,000원
        50.
        2010.08 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Nano sized SiC particles (270 nm) are easily agglomerated in nickel sulfamate electrolytic bath during a composite electrodeposition process. The agglomeration of nano particles in composite coatings can significantly reduce the mechanical properties of the composite coatings. In this study, Ni-SiC nano composite coatings were fabricated using a conventional electrodeposition process with the aid of ultrasound. Nano particles were found to be distributed homogeneously with reduced agglomeration in the ultrasonicated samples. Substantial improvements in mechanical properties were observed in the composite coatings prepared in presence of ultrasound over those without ultrasound. Ni-SiC composite coatings were prepared with variable ultrasonic frequencies ranging from 24 kHz to 78 kHz and ultrasonic powers up to 300 watts. The ultrasonic frequency of 38 kHz with ultrasonic power of 200 watt was revealed to be the best ultrasonic conditions for homogeneous dispersion of nano SiC particles with improved mechanical properties in the composite coatings. The microstructures, phase compositions, and mechanical properties of the composite coatings were observed and evaluated using SEM, XRD, Vickers microhardness, and wear test. The Vickers microhardness of composite coatings under ultrasonic condition was significantly improved as compared to the coatings without ultrasound. The friction coefficient of the composite coating prepared with an ultrasonic condition was also smaller than the pure nickel coatings. A synergistic combination of superior wear resistance and improved microhardness was found in the Ni-SiC composite coatings prepared with ultrasonic conditions.
        4,000원
        51.
        2009.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Central composite design was applied for the ultrasound-assisted extraction from peel and seed of Campbell Early grapes and the extraction processes were optimized for the antiradical activities of the extracts by using response surface methodology. Optimal conditions were 53.45% of ethanol concentration, 45.99oC of extraction temperature and 23.93 min of extraction time for the maximum antiradical activity of grape peel extract (54.98%) and 53.14% of ethanol 56.03oC of temperature and 29.03 min of time for maximum antiradical activity of grape seed extract (90.60%).
        4,000원
        52.
        2008.07 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        ZnO nanorod gas sensors were prepared by an ultrasound radiation method and their gas sensing properties were investigated for NO gas. For this procedure, 0.01, 0.005 and 0.001M of zinc nitrate hydrate [Zn(NO3)2 · 6H2O] and hexamethyleneteramine [C6H12N4] aqueous solutions were prepared and then the solution was irradiated with high intensity ultrasound for 1 h. The lengths of ZnO nanorods ranged from 200 nm to 500 nm with diameters ranging from 40 nm to 80 nm. The size of the ZnO nanorods could be controlled by the concentration of solution. The sensing characteristics of these nanostructures were investigated for three kinds of sensor. The properties of the sensors were influenced by the morphology of the nanorods.
        4,000원
        53.
        2008.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
          The objective of this paper is to remove noises of image based on the heuristic noises filter and to extract a tumor region by using morphology techniques in breast ultrasound image. Similar objective studies have been conducted based on ultrasound imag
        4,000원
        54.
        2007.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was performed to establish the early pregnancy diagnosis with evaluation of size of embryonic vesicles and change of crown-rump length (CRL) by transrectal ultrasonography in the Korean black goats. Early pregnancy diagnosis was performed in the 114 goats from 19 to 35 days after coitus by transrectal 5.0 MHz transducer. Embryonic vesicles and CRL in the 142 goats from 19 to 42 days was measured to establish the correlation between gestational age and these parameters. The early pregnancy diagnosis achieved 80% accuracy after days 25 and 100% accuracy after days 28 after breeding. Diameters of embryonic vesicle and CRL were significantly increased with the gestational age. In these facts, early pregnancy diagnosis is possible on Days 25 after breeding and measurement of embryonic vesicles and CRL were useful to predict the gestational age in Korean black goat.
        3,000원
        55.
        2007.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to investigate the effect of parity and region on the live body charateristics of Hanwoo cows. The data used were logissimus muscle area (LMAU), back fat thickness (BFTU), marbling score (MSU), and p8 point fat thickness (P8 FTU), by ultrasound from 1,239 heads of hi-lok branded Hanwoo cows. Based upon ultrasound characteristics of LMAU, BFTU, MSU and P8 FTU were significantly high in Hanwoo cows in Hwacheon area. Live body characteristics were increased with the parity, however estimated value tended to decreased after sixth parturition. Also, comparative of pre or after parturiti- on on the live body characteristics, pre parturition value showed little lower than after parturition
        4,000원
        56.
        2007.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to investigate electromyographic activities of the flexor digitorum superficialis (FDS) and the flexor carpi ulnaris (FCU) by the shape of the ultrasound head. Twelve healthy subjects participated and performed ultrasound therapy with a round head and a long handled head during each 5-minute application. Electromyographic activities of the FDS and FCU were recorded by surface electrodes and normalized by maximal voluntary isometric contraction (MVIC) values. There was no difference in the muscular fatigue of FDS and FCU as determined by the shape of the ultrasound head (p>.05). Without the shape of head, the mean power frequency decreased with the time. There also was no difference in %MVIC of the FDS and FCU as determined by the shape of the ultrasound head (p>.05), but the force exerted exceeded 20%MVIC. There was however a significant difference in the amount of cumulative workload of the FDS and FCU as determined by the shape of ultrasound head (p<.05). The workload was however not affected by the shape of the ultrasound head. Constant static grasp of ultrasound transducer head during ultrasound therapy is considered a high risk factor of work-related musculoskeletal disease.
        4,000원
        57.
        2007.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was designed to determine the efficacy of ultrasound and laser therapy for sub-acute lower back pain. Twenty-seven patients with sub-acute low back pain were recruited, who were randomly assigned to three groups: Ultrasound group (actual ultrasound, 1.1 MHz, , duty cycle 100%, 10 min/session, n=9), laser group (actual laser, 904 nm, 155 ns, 13.5 W, 12 mW, 90 sec/point, n=9), and control group (placebo ultrasound or placebo laser, n=9). All of treatments including placebo procedures were applied to patients over a period of 2 weeks, five times a week. Visual Analogue Scale (VAS), Modified Schober's Test (MST), and Modified Oswestry Disability Questionnaire (MODQ) were used by the clinical and functional evaluations before and after intervention. At post-hoc, significant differences were observed in all groups with respect to VAS, MST (p<.05), except MODQ. VAS and MST score were more significantly improved in the ultrasound group than the laser and control group (p<.0167). However, no significant difference was present between the laser group and the control group. Therefore, this study revealed that ultrasound therapy was effective in pain relief and improvement of lumbar mobility in patients with sub-acute lower back pain. However, laser therapy did not show the effects for sub-acute lower back pain.
        4,000원
        58.
        2006.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to assess the effects of High-Voltage Pulsed Current (HVPC) and ultrasound on adjuvant-induced arthritis in rats. Adjuvant arthritis was induced in female Sprauge-Dawley rats by the subcutaneous injection of a single dose of 1 ㎖ of Complete Freund's Adjuvant (CFA) (1 mg of Mycobacterium Butyricum suspended in 1 ㎖ paraffin oil) into the right hind paw. A randomized, parallel-groups design of 24 subjects was used. All rats were randomly assigned to control (n=8), ultrasound (n=8), and HVPC (n=8) were compared with those of injured rats. The rats in the pulsed ultrasound group were treated at 1 MHz frequency with 5 W/㎠ intensity in 1:4 mode for 5 minutes per day. The rats in the HVPC group were treated at 120 pulses per second and 50 ㎲ phase duration, 20 mA intensity for 30 min per day. Treatment was done in the left and right hind limb for 2 weeks. We evaluated clinical, radiographic, hematologic and histopathologic findings before and after treatment and obtained the following results. 1. Edema of the right hind paw was more significantly reduced in the ultrasound and HVPC groups than the control group on days 9, 12, and 14 (p<.05). Edema of the left hind paw was more significantly reduced in ultrasound and HVPC groups than the control group on days 12, 14 (p<.05). 2. WBC counts of the ultrasound and HVPC groups as compared with the control group were becoming remarkably decreased after the treatment. 3. In radiologic findings, arthritis formation was seen according to the score of arthritis, which was the highest in the control group, upon the observation of radiographs of the left and right hind paws. However, no statistically significant difference was present in the score within three groups. 4. In the histopathologic findings, ultrasound and HVPC groups had effectively suppressed erosions of articular cartilage and inflammatory cell infiltrations. Therefore, the results of the study show that rats that were treated with the ultrasound and HVPC effectively suppressed adjuvant arthritis. However, no statistically significant difference was present between the ultrasound group and the HVPC group.
        4,000원
        60.
        2006.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Since ultrasound has different reflections depending on components of organization, analysis of ultrasound images of skeletal muscle can offer both quantitative and qualitative reports as concerns skeletal muscle structure. This study is focused on the ultrasound method for evaluating the structural characteristics of skeletal muscle and also conducted to examine its practicality. After obtaining images of the elbow flexors from an ultrasound image device with 88 normal subjects whose ages were between twenty and seventy years old (44 men and 44 women), muscular density and white area index (WAI) which indicated structural characteristics of skeletal muscle were analyzed with gray scale analysis. The study examined correlations between subject's age and items which obtained from measuring ultrasound images and the differences in relations to sex and age. Muscular density and WAI had a high correlation with age and were significantly increased in men and women with greater age. The quantitative evaluation method of skeletal muscle structure which analyzed the ultrasound images has high practicality because it is a non-invasive method which complements physical therapy diagnosis and research methods and promotes functionality evaluation.
        4,000원
        1 2 3 4 5