검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 16

        1.
        2018.04 구독 인증기관 무료, 개인회원 유료
        The office building more than 3,000㎡ of the total floor area should be needed to improve the energy efficiency based on government's recommendation. In this study, the new composite panel with structural function is conducted to check the thermal conductivity for application of exterior wall. The thermal transmittance was calculated by dynamic analysis to consider the thickness of insulation only per locations based on design criteria. The simulation program for the analysis was used TRISCO Radcon module, which has a function of a steady-state 3-dimensional heat transfer analysis.
        3,000원
        2.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to make a generalized analytical based on the proposed experiments on reinforced concrete(RC) partially infilled frames by U-type precast concrete(PC) wall panels with openings. RC frame and PC wall panels were connected with different strengths. Therefore, we developed modified strut-tie model(STM) with two seismic retrofitting specimens and conducted a nonlinear analysis by using a computer analysis program. Based on the test results, truss member of modified STM was designed, applying the strut-tie model theory of ACI 318M-11 Appendix- A. As a result, the modified STM analysis results were very similar to the experimental results. As a result of the load-displacement curve comparison, the failure load were similar within 5∼17% of error range. In particular, the experimental results and the results of modified STM analysis show that the failure behavior almost matched.
        4,200원
        3.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Cyclic loading test was performed on the partially infilled reinforced concrete(RC) frames by L-type precast concrete(PC) wall panels with the connections of two different strength. Based on the results of experimental test, the nonlinear analysis was practiced with modified strut-tie model(STM) method by using a computer program. Truss member of modified STM was designed, applying the strut-tie model theory of ACI 318M-11 Appendix-A. Modified STM was designed with two ways according to the test result. PC wall panel and RC frame were assumed to composite when push loading applied. The PC and RC structures were also assumed to behave non-composite and those two structures connected with link(top connector) when pull loading applied. The connection was designed by using elastic link of program. The results of analytical modified STM process generally conform to the experimental results. The failure load and the failure mode of the specimens could be predicted using modified STM. The ratio of failure load measured in specimens to analytical values were between 0.83∼1.16. The member or connection which was failed in experiment yield in the results of modified STM. The failure mode perfectly matched.
        4,500원
        6.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.
        4,500원
        7.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims at developing a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. Top shear connection of the PC panel was required to show the composite strength of RC column and PC wall panel. However, the strength of the connection did not influence directly on the ultimate loading capacities of the specimens in the positive loading because the loaded RC column push the side of PC wall panel and it moved horizontally before the shear connector receive the concentrated shear force in the positive loading process. Under the positive loading sequence(push loading), the reinforced concrete column and PC panel showed flexural strength which is larger than 97% of the composite section because of the rigid binding at the top of precast panel. Similar load-deformation relationship and ultimated horizontal load capacities were shown in the test of PR1-LA and PR1-LP specimens because they have same section dimension and detail at the flexural critical section. An average of 4.7 times increase in the positive maximum loading(average 967kN) and 2.7 times increase in the negative maximum loading(average 592.5kN) had resulted from the test of seismic resistant specimens with anchored and welded steel plate connections than that of unreinforced beam-column specimen. The maximum drift ratios were also shown between 1.0% and 1.4%.
        4,200원
        8.
        2011.04 구독 인증기관 무료, 개인회원 유료
        This study aims at grasping the structural performances of primary anchor assemblage through a nonlinear finite element analysis. Primary anchor unit may be used as one of the connection devices between ALC panel curtain-wall and RC slab or main frame of a building. From the analytical results structural characteristics such as yield strength, initial stiffness and maximum strength are obtained and compared with test results.
        3,000원
        9.
        2011.03 구독 인증기관 무료, 개인회원 유료
        교류형 플라스마 디스플레이에서 Vt 폐곡선이라는 3 전극의 벽전압 분석에 의해 셀 내부의 벽전하 상태를 측정하고 Vt 폐곡선을 이용하여 구동파형에 따른 오방전의 발생하는 원인을 유도한다. 플라스마 디스플레이는 셀 내부에서 플라스마 방전에 의해 화면을 표시하는 소자이고, 플라스마 방전에 의해 각 전극에 쌓여진 벽전하는 외부 인가전압과 별도로 셀 내부에 전극 간의 벽전압을 형성한다. 교류형 플라스마디스플레이의 전극은 일반적으로 3개이기 때문에 셀 내부의 벽전하 상태를 측정하는 것은 어려우나 Vt 폐곡선이라는 벽전압 분석 법을 이용하면 셀 내부의 상태를 예측할 수 있다. 본 논문은 먼저 Vt 폐곡선의 모양, 외부 인가전압에 대한 전압 벡터, 측정방법 등에 대하여 소개를 하고, 플라스마 디스플레이의 종래와 테스트 구동파형에서 초기화 기간의 하강 경사파 전압에 따른 Vt 폐곡선을 각각 그린다. 초기화 기간 중 최종 전압을 종래보다 많이 낮게 인가한 테스트 구동 파형에서 발생하는 오방전의 원인을 측정된 Vt 폐곡선에 의해 발견할 수 있다.
        4,000원
        10.
        2011.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 Primary Anchor의 비선형 유한요소해석을 통해 구조적 성능을 파악하는데 목적이 있다. Primary Anchor Unit은 ALC 패널 커튼월과 RC 슬래브 또는 주골조 사이에 연결장치로 사용할 수 있다. 항복강도, 초기강성과 최대 하중과 같은 구조적 특성을 구하고 자세히 비교분석하였다.
        4,000원
        11.
        2018.04 서비스 종료(열람 제한)
        In this study the cyclic lateral loading tests were performed on the hybrid precast concrete panels that are interconnected by dry joints to emulate concrete shear wall cores for a mid-rise modular building. Test results show that it is necessary to improve the details of vertical reinforcement welded to the flange of C section member to increase the lateral resistance of hybrid precast concrete panels.
        12.
        2016.04 서비스 종료(열람 제한)
        To improve the wet process of concrete core wall, which is one of lateral load resisting system in high-rise modular building, the new composite panel system is developed and its structural performance under lateral load is investigated analytically.
        13.
        2015.11 KCI 등재 서비스 종료(열람 제한)
        이 연구의 목표는 학교 건물과 같은 저층 보-기둥 철근콘크리트 구조 건물에서 프리캐스트 벽패널을 사용한 새로운 내진보강 방법 을 개발하는데 있다. 1개의 무 보강 보-기둥 실험체와 U형 PC 패널로 보강한 2개의 보강 보-기둥 실험체에 대한 정적 이력 하중실험을 진행하 였다. 앵커 접합부 실험체는 전단 파괴될 것으로 해석되었고 철판 용접 접합부 실험체는 휨 파괴할 것으로 예측되었다. 실험체의 종국 내력은 상부 접합부의 전단 내력과 PC 패널 절곡 부 휨 위험단면에서 휨 내력 중 약한 것으로 결정되었다. 이 실험체에서, 한쪽 RC기둥이 가 하중(미는 실험 하중)을 받아 PC 패널 부재를 밀게 된다면, 다른 쪽 내부 수직부재는 상부 전단 접합부로부터 부 하중(당기는 실험 하중)을 받게 되어있었 다. 가 하중을 받는 2개의 부재는 합성 휨 거동이 지배적이므로 합성단면의 휨 내력이 실험체의 최종 내력을 결정하게 되지만, 이 경우 최종 내 력에 대하여 상부 전단 접합부 강도의 직접적인 영향은 없다고 볼 수 있다. 그러나 부 하중(당기는 하중)을 받는 RC 기둥과 PC 패널 부재는 비 합성 거동이 지배적이고 실험체의 최종 내력은 상부 전단 접합부 전단내력의 크기에서 직접 영향을 받는 것으로 파악되었다. ACI 318M-11 Appendix-D 앵커 전단설계에 기초한 전단내력 그리고 실험에서 얻은 최대하중을 적용하여 마이다스 젠 탄성설계에 의하여 계산한 전단 외력 에 대한 비교 해석결과는 실험결과와 일치하는 해석결과를 보여주었다.
        14.
        2015.09 KCI 등재 서비스 종료(열람 제한)
        이 연구의 목표는 학교 건물과 같은 저층 보-기둥 철근콘크리트 구조 건물에서 프리캐스트 벽패널을 사용한 새로운 내진보강 방법을 개발하는 것이다. 1개의 무 보강 보-기둥 실험체와 U형 PC 벽패널로 보강한 2개의 보강 보-기둥 실험체에 대한 정적 이력 하중실험을 진행하였다. 앵커접합 PR1-UA 실험체와 철판접합 PR1-UP 실험체는 무 보강 실험체보다 평균 2.8배(평균 591.8 kN)의 강도 증가를 보여 주었다. 최대 변위비도 1.4%에서 2.7%사이 값을 보여주었다. RC 골조 우측 상단에서 좌측방향으로 가력 할 때 우측에 있는 RC 기둥과 보강 PC 패널의 수직 요소는 완전 합성상태로 가정하였고, 좌측에 있는 RC 기둥과 PC 패널은 완전 비 합성 거동하는 것으로 가정하여 해석한 결과 전체적인 휨 거동은 실험 결과와 대체적으로 부합하는 것으로 판단되었다.
        15.
        2013.04 서비스 종료(열람 제한)
        Heat insulator materials can be classified inorganic and organic. The organic material is due to toxic gas emission, when a fire occurs. And it has lower water resistance. The inorganic material is heavy and worse thermal performance than organic materials. This study focused on evaluation of the physical properties of light-weight inorganic foam panel for using industrial by-products materials and performance evaluation by mock up test.
        16.
        2011.02 서비스 종료(열람 제한)
        건축물의 단열은 효율적인 에너지 사용을 위한 필수적인 기술이다. 중단열 콘크리트 외벽 시스템은 내/외측에 두 개의 콘크리트 벽체와 중앙부 단열재로 구성되어, 단열성능과 구조성능을 동시에 만족시킬 수 있는 시스템이다. 중단열 콘크리트 외벽 시스템을 구조체에 적용하기 위해서는 콘크리트와 단열재 부착면의 전단내력에 대한 검증이 필연적으로 요구된다. 본 연구는 파형 FRP 전단연결재로 보강한 중단열 콘크리트 외벽 시스템의 전단연결재의 매립깊이, Pitch, 폭에 따른 전단내력을 평가하기 위하여 실시되었다. 실험결과 동일단면적에서 Pitch가 넓은 경우 전단내력이 소폭으로 증가하는 결과를 보였다. 매립깊이가 깊을수록 전단내력을 증가하였고, 폭 12mm 와 18mm의 경우 각 각 35, 40mm 이상의 매립깊이가 필요할 것으로 판단된다.