검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 10

        1.
        2019.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this theoretical study, a design and performance analysis theory of a micro flowrate and high pressure air-compressor is developed. The governing equations are from the gas state equation and fluid dynamic theories because the working fluid in the air compressor is in a gas phase. A case study was conducted to design a reciprocating type of air compressor which the target performance was 0.6liter/min in the volume flowrate with 5atg in air pressure at 1,600rpm rotational speed. Geometrical size of the model air compressor designed is 10mm in stroke, 20mm in bore with 4.79 compression ratio. From the performance analysis of the model compressor, it was found that the air volume flowrate produced was 0.6liter/min with 5.81atg in pressure. The design theory of a micro-size high-pressure air compressor developed in this study is expected to be very useful design tools in NANO technology industry.
        4,000원
        2.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 이미 보고된 잉여 태양에너지 관련 연구결과와 현재 현장에 설치되어 있는 냉난방용 FCU 현황을 개략적으로 검토한 후, 잉여 태양에너지 회수에 필요한 FCU의 소요대수 결정 방법을 개략적으로 제시하여 앞으로 이 분야의 연구자 및 기술자들에게 기조자료를 제시할 목적으로 연구를 수행하였다. 실험기간 동안 최대, 평균 및 최저 외기온은 각각 28.2oC, 4.4oC 및 -11.5oC정도였다. 온실 밖의 수평면 일사량은 0.8~20.5MJ·m-2로 정도의 범위였으며, 평균 및 총 일사량은 10.8MJ·m-2 및 1,187.5MJ·m-2으로 나타났다. 그리고 주간동안 온실 내의 평균기온과 상대습도는 각각 18.8~45.5 및 53.5~77.5%정도였다. 실험기간 동안 온실로부터 회수한 총 잉여 태양에너지는 6,613.4MJ정도로서 총 난방에너지인 98,600.2MJ 약 6.7%정도를 보충할 수 있을 것으로 나타났다. 또한 사양이 유사한 FCU를 사용하지만, 난방을 위하여 설치되는 FCU의 대수는 제각각 다른 것을 알 수 있었고, 좀 더 효율적이고 경제적인 관점에서 설치높이, 방향 및 설치 간격, 적정 대수에 대한 연구가 이루어져야 할 것으로 판단된다. 잉여 태양에너지 회수용 FCU의 적정 소요대수는 FCU를 통과하는 공기의 질량 및 순환유량을 기준으로 각각 8.4~10.9대 및 6.1~8.0대 정도이었다. 여기에 계산방법이나 FCU의 효율 및 사용 환경 등 위험률을 고려하면, 결국 9대 전후(약 24m3당 1대 정도)를 설치하면 될 것으로 판단되었다.
        4,000원
        3.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study was to investigate the response characteristics and performance of a biofilter in the removal of ammonia, as a malodor compound. A trickle-bed type biofilter was applied for this study, and operated at the ammonia loading rate of 0.97-15.52 g/m3·h. The results of the experiment indicate that the critical loading rate of ammonia to the biofilter was 10.7 g/m3·h and the elimination capacity was 11.6 g/m3·h. The analysis of nitrogen mass balance in the reactor indicates that inlet nitrogen as gas phase was converted through the biofilter into NH4 + (41.5% by mass), NO2 - (43%), and NO3 - (15%) as the available form of nitrogen in the effluent liquid. Free ammonia concentration in the effluent liquid was estimated as being in the range from 0.14 to 2.93 mg/L (average 1.7 mg/L) during the experimental period.
        4,000원
        6.
        2018.10 KCI 등재 서비스 종료(열람 제한)
        본 연구는 자동노출제어 (AEC; Automatic Exposure Control)를 이용한 복부 일반 X선 검사에서 체질량지수 (BMI; Body Mass Index)가 입사표면공기커마 (ESAK; Entrance Surface Air Kerma)에 미치는 영향에 대해 알아보았다. 연구방법은 AEC를 이용하여 복부 일반 X선 검사를 시행 받은 321명을 대상으로 키, 몸무게, BMI와 ESAK의 관계 및 BMI범주 (Underweight, Normal, Overweight, Obese 1, Obese 2)에 따른 평균 ESAK값을 비교하였다. 연구의 결과 몸무게 (R2=0.777, p<.001)와 BMI (R2=0.835, p<.001)는 ESAK와 양의 상관관계가 있었던 반면, 키 (R2=0.075, p<.001)와 BMI는 뚜렷한 상관관계를 확인할 수 없었다. BMI범주에 대한 평균 ESAK는 통계적으로 유의한 차이를 보였으며, 사후분석을 통해 유의수준 0.05에 대해 5개의 부집단이 존재하여 모든 BMI범주 간 ESAK값의 차이가 있는 것을 알 수 있었다. 또한, 인접한 BMI간 ESAK값 증가폭이 Underweight에서 Obese 2로 갈수록 점차 늘어나 BMI가 증가할수록 피폭선량이 급격하게 증가되는 것을 알 수 있었다. 따라서 복부 일반 X선 검사에서 AEC를 사용할 경우 BMI가 증가함에 따라 과도한 선량이 조사될 수 있음을 인식하고 검사조건을 고정하여 촬영하는 등의 노력을 통한 선량저감화가 필요할 것으로 판단된다.
        7.
        2012.07 KCI 등재 서비스 종료(열람 제한)
        This study analyzed mass concentrations of TSP, PM10 and PM2.5 and elemental constituents according to the isentropic backward trajectories of air parcel from Cheongwonin East Asia during the period January – October, 2011. Mass concentrations of the continental polluted airflow (CP) showed levels of TSP and PM10 mass concentrations higher than the continental background airflow (CB). Also, PM2.5 mass concentrations of anthropogenic fine particles ran higher in CP than in CB. The elemental constituents and elemental constituent ratio ended up varying depending on the origin of atmospheric aerosols generated. The average absolute content of elemental constituents reached its height in CB, the ratio of anthropogenically originating elements (PE) among the all elements (AE) analyzed marked a high in CP, and Mg+Na/AE reached its height in the oceanic airflow (OA). At the same time, TSP, PM10 and PM2.5 mass concentrations, the ratio of PM2.5/TSP and PE/AE element ratio ran higher in CP than CB. Episodes of large-scale transport of atmospheric pollutants as observed at Cheongwon were 8 cases and 22 days. The ratios of PM10, PM2.5 among TSP mass concentrations showed different results and the ratios of PM2.5 showed an increasing trend in the episodes of anthropogenic air pollution transport. Overall, dustfall episodes show a level of elemental constituents higher than those of anthropogenic air pollution.Dustfall episodes were observed to contain more of Fe, Al and Ca originating from continental soils and those of air pollution were observed to contain more of Zn, Mn, Cu and Pb. By difference in contents of absolute elemental constituents, episodes of anthropogenic air pollution showed a high PE/AE rate, and dustfall episodes a high SE/AE rate.
        8.
        2010.02 KCI 등재 서비스 종료(열람 제한)
        Air mass recirculation is a common characteristic in the coastal area as a result of the land-sea breeze circulation. This study simulates the recirculation of air mass over the Gwangyang Bay using WRF-FLEXPART and offers a basic information about the effective domain size that can reflect recirculation. For this purpose, WRF is set up four nested domains and three cases are selected. Subsequently FLEXPART is operated on the basis of WRF output. During the clear summer days with weak wind speed, particles that emitted from Yeosu national industrial complex and Gwangyang iron works flow into emission sources because of the land-sea breeze. When land-sea breeze is strengthen, the recirculation phenomena appears clearly. However particles aren't recirculated under weak synoptic condition. Also plume trajectory is analyzed and as a consequence, the smallest domain area have to be multiplied by 1.3 to understand recirculated dispersion pattern of particles.
        9.
        2006.10 KCI 등재 서비스 종료(열람 제한)
        Despite the wide distribution of air pollutants, the concentrations of indoor air pollutants may be the dominant risk factor in personal exposure due to the fact that most people spend an average of 80% of their time in enclosed buildings. Researches for improvement of indoor air quality have been developed such as installation of air cleaning device, ventilation system, titanium dioxide(TiO2) coating and so on. However, it is difficult to evaluate the magnitude of improvement of indoor air quality in field study because indoor air quality can be affected by source generation, outdoor air level, ventilation, decay by reaction, temperature, humidity, mixing condition and so on. In this study, evaluation of reduction of formaldehyde and nitrogen dioxide emission rate in indoor environments by TiO2 coating material was carried out using mass balance model in indoor environment. we proposed the evaluation method of magnitude of improvement in indoor air quality, considering outdoor level and ventilation. Since simple indoor concentration measurements could not properly evaluate the indoor air quality, outdoor level and ventilation should be considered when evaluate the indoor air quality.
        10.
        2003.04 KCI 등재 서비스 종료(열람 제한)
        This study was performed to research ozone concentration related to airmass thunderstorm using 12 years meteorological data(1990~2001) at Busan. The occurrence frequency of thunderstorm during 12 years was 156 days(annual mean 13days). The airmass thunderstorm frequency was 14 days, most of those occurrence at summertime(59%). In case August 4, 1996, increase of ozone concentration was simultaneous with the decrease of temperature and increase of relative humidity. In case July 23, 1997, ozone concentration of western site at Busan increased, while its of eastern site decreased as airmass thunderstorm occurred(about 1500LST). It is supposed that these ozone increases are the effect of ozone rich air that is brought down by cumulus downdrafts from height levels where the ozone mixing ratio is larger. Thunderstorms can cause downward transport of ozone from the reservoir layer in the upper troposphere into planetary boundary layer(PBL). This complex interaction of source and sink processes can result in large variability for vertical and horizontal ozone distributions. Thus a variety of meteorological processes can act to enhance vertical mixing between the earth's surface and the atmospheric in the manner described for thunderstorm.