        103.
        2018.05 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Hot-press forming(HPF) steel can be applied successfully to auto parts because of its superior mechanical properties. However, its resistances to aqueous corrosion and the subsequent hydrogen embrittlement(HE) decrease significantly when the steel is exposed to corrosive environments. Considering that the resistances are greatly dependent on the properties of coating materials formed on the steel surface, the characteristics of the corrosion and hydrogen diffusion behaviors regarding the types of coating material should be clearly understood. Electrochemical polarization and impedance measurements reveal a higher corrosion potential and polarization resistance and a lower corrosion current of the Al-coating compared with Zn-coating. Furthermore, it was expected that the diffusion kinetics of the hydrogen atoms would be much slower in the Al-coating, and this would be due mainly to the much lower diffusion coefficient of hydrogen in the Al-coating with a face-centered cubic structure. The superior surface inhibiting effect of the Al-coating, however, is degraded by the formation of local cracks in the coated layer under severe stress conditions, and therefore further study will be necessary to gain a clearer understanding of the effect of cracks formed on the coated layer on the subsequent corrosion and hydrogen diffusion behaviors.
        4,000원
        104.
        2018.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Applicability of corrosion inhibitor was evaluated using pilot scale water distribution pipe simulator. Calcium hydroxide was used as corrosion inhibitor and the corrosion indices of the water were investigated. Corrosion indices, Langelier saturation index (LI) increased by 0.8 and calcium carbonate precipitation potential (CCPP) increased by 9.8 mg/L. This indicated that corrosivity of water decreased by corrosion inhibitor and the effects lasted for 18 days. Optimum calcium hydroxide dose was found to be 3~5 mg/L for corrosion inhibition. We suggest that monitoring of CCPP as well as LI need to be conducted to control corrosivity of water.
        4,000원
        105.
        2018.04 구독 인증기관·개인회원 무료
        In this study, the long-term performance of FRP Hybrid Bar made by hybridizing FRP (Fiber Reinforced Polymer) with ordinary reinforcing steel bars was experimentally examined as a part of the development of alternative materials for RC (reinforced concrete) structures especially located in marine or harbor areas. In order to evaluate the field exposure of the FRP Hybrid Bar, the specimen was prepared and the corrosion behavior was evaluated by letting the specimen exposed to the field conditions in the west coast of South Korea. The purpose of this study is to provide important data as a material countermeasure to reduce corrosion of reinforcing steel in future marine port concrete structures based on the results obtained through this study.
        111.
        2017.10 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Evaluation of the durability and stability of materials used in power plants is of great importance because parts or components for turbines, heat exchangers and compressors are often exposed to extreme environments such as high temperature and pressure. In this work, high-temperature corrosion behavior of 316 L stainless steel in a carbon dioxide environment was studied to examine the applicability of a material for a supercritical carbon dioxide Brayton cycle as the next generation power plant system. The specimens were exposed in a high-purity carbon dioxide environment at temperatures ranging from 500 to 800 oC during 1000 hours. The features of the corroded products were examined by optical microscope and scanning electron microscope, and the chemical compound was determined by x-ray photoelectron spectroscopy. The results show that while the 316 L stainless steel had good corrosion resistance in the range of 500-700 oC in the carbon dioxide environment, the corrosion resistance at 800 oC was very poor due to chipping the corroded products off, which resulted in a considerable loss in weight.
        4,000원
        112.
        2017.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        ber reinforced polymer (FRP) reinforcing bars for concrete structure have been extensively investigated and a number of FRP bars are commercially available. However, major shortcoming of the existing FRP bars is low elastic modulus compared to conventional steel bars. Because of these reasons, FRP Hybrid Bar which have the concept of material hybridization(synthetic resins, deformed bar, glass fiber etc) for concrete structures have been developed. One of main features of this bar is corrosion resistance and this is important to confirm this anti-corrosion capacity of FRP Hybrid Bar. In this study, galvanic corrosion current behavior of 3 types of specimens, including two types of FRP Hybrid Bars and one conventional steel rebar, was investigated under the 0%, 1.5%, 3% and 6% salt water ratio condition. The result of this study can be used to evaluate the applicability of FRP Hybrid Bar to concrete structures.
        4,000원
        113.
        2017.08 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        This study investigated the surface pit corrosion of SS420J2 stainless steel accompanied by intergranular crack. To reveal the causes of surface pits and cracks, OM, SEM, and TEM analyses of the microstructures of the utilized SS420J2 were performed, as was simulated heat treatment. The intergranular cracks were found to have been induced by a grain boundary carbide of (Cr,Fe)23C6, which was identified by SEM/EDS and TEM diffraction analyses. The mechanism of grain boundary sensitization occurred at the position of the carbide, followed by its occurrence at the Cr depleted zone. The grain boundary carbide of (Cr,Fe)23C6 type precipitated during air cooling condition after a 1038 °C solid solution treatment. The carbide precipitate formation also accelerated at the band structure formed by cold working. Therefore, using manufacturing processes of cooling and cold working, it is difficult to protect SS420J2 stainless steel against surface pit corrosion. Several counter plans to fight pit corrosion by sensitization were suggested, involving alloying and manufacturing processes.
        4,000원
        114.
        2017.06 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        KAERI에서는 파이로프로세싱에서 발생하는 금속폐기물의 부피 및 무게 감량을 위해 고방사성 장반감기 핵종을 포함하는 anode sludge내 NM의 고화매질로써 폐피복관과 첨가금속을 재활용하는 연구를 진행하고 있다. 본 연구에서는 Cr 함량을 조절한 Zr-17Cr-8NM, Zr-22Cr-8NM, Zr-27Cr-8NM 합금을 유도용융을 통해 제조하였고, 전기화학적 부식시험을 실시하여 부 식특성을 평가하였다. 모든 조성에서 기존 연구 중인 Zr계 합금고화체 조성보다 우수한 부식특성을 나타냈다. 또한 Zr-22Cr- 8NM 시편의 부식시험 후 침출용액 조성 분석 결과, 500 mV 전압 조건 이하에서는 NM 침출이 없었고 이를 통해 우수한 화 학적 안정성을 갖는 합금고화체 조성을 확보하였다.
        4,000원
        118.
        2017.04 구독 인증기관 무료, 개인회원 유료
        To overcome shortcomings of fiber reinforced polymer (FRP), a hybridized FRP rebar was developed by the authors. This hybrid bar herein called “FRP Hybrid Bar” was fabricated by adopting advantages from two different materials, including glass fiber reinforced polymer (GFRP). Corrosion resistant characteristics of FRP Hybrid Bar were evaluated and the test results were explained in this paper. The use of the alternative reinforcement could allow concrete structures to extend life-span, to save maintenance and repair costs, etc. if the FRP Hybrid Bar was applied to RC structures located in a very corrosive environment, such as marina or harbor areas.
        3,000원
        119.
        2017.04 구독 인증기관 무료, 개인회원 유료
        Corrosion is one of the most typical aging phenomena associated with long-term use of steel structures. Corrosion of high-tension bolted connections causes problems such as reduction of thickness of member and relaxation of axial force of high-tension bolt, thereby reducing load-carrying capacity of high-tension bolted connections. In this study, three specimens were subjected to natural corrosion in order to evaluate the residual load-carrying capacity of high-tension bolted connections where corrosion occurred. Two specimens were newly fabricated for comparison with the corroded specimens. In addition, the static bending test was performed to compare and investigate the behavior characteristics of the high-tension bolted connections and the final failure modes. The residual load-carrying capacity of the corroded high-tension bolted connections was evaluated.
        3,000원
        120.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to prevent secondary pollution of tap water, corrosion characteristics are investigated, and corrosion index are calculated using LI and LR to manage corrosiveness. As targeted water treatment plants from 2014 (July, once) to 2015 (July and October, 2 times), 70 plants are selected by making a division for each area and water system. (treated water samples, n=240, raw water samples, n=72). In result of pH analysis, treated water was lower than raw water to 7.12, and 7.29, respectively. LI were investigated in the order of Seomjin river, Nakdong river, Han river, Geum river, to -2.08, -1.24, -1.11, -1.10 (at raw water), and -2.18, -1.59, -1.51, -1.35 (at treated water), respectively. In case of water quality goal value (LI = -1) in Japan as control of corrosiveness, management object was investigated about 83.3%.
        4,000원