검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 4

        2.
        2017.10 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        In commercial solar cells, the pattern of the front electrode is critical to effectively assemble the photo generated current. The power loss in solar cells caused by the front electrode was categorized as four types. First, losses due to the metallic resistance of the electrode. Second, losses due to the contact resistance of the electrode and emitter. Third, losses due to the emitter resistance when current flows through the emitter. Fourth, losses due to the shading effect of the front metal electrode, which has a high reflectance. In this paper, optimizing the number of finger on a 4 ´ 4 solar cell is demonstrated with known theory. We compared the short circuit current density and fill factor to evaluate the power loss from the front metal contact calculation result. By experiment, the short circuit current density(Jsc), taken in each pattern as 37.61, 37.53, and 37.38 mA/ cm2 decreased as the number of fingers increased. The fill factor(FF), measured in each pattern as 0.7745, 0.7782 and 0.7843 increased as number of fingers increased. The results suggested that the efficiency(Eff) was measured in each pattern as 17.51, 17.81, and 17.84 %. Throughout this study, the short-circuit current densities(Jsc) and fill factor(FF) varied according to the number of fingers in the front metal pattern. The effects on the efficiency of the two factors were also investigated.
        4,000원
        3.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 홍수기 유량측정의 어려움을 극복하고자 물 과 비접촉식으로 유속을 측정하여 유량을 산정하는 전 자파표면유속계(microwave water surface current meter, MWSCM)의 성능개선 제품인 범용 MWSCM에 대하여 소개하고자 하였다. 기존에 사용 중인 MWSCM은 홍수 용으로써 연중 활용도가 낮아 이것의 이용성을 높이고 자 성능을 개선하였다. 유속측정 범위를 확장하여 평∙ 갈수기에도 하천 유량측정이 가능하게 하였다. 즉 기존 홍수용 MWSCM의 유속측정 범위가 0.5~10.0 m s-1이 었던 반면, 금번에 개발된 범용 MWSCM은 0.03~20.0 m s-1로 홍수기 및 평수기 측정이 가능하도록 성능을 개선하였다. 이를 위해서 사용주파수의 변경(10 GHz → 24 GHz), 안테나 및 송수신부 회로가 새롭게 설계 제작 되었다. 이와 더불어 기존 홍수용 MWSCM 사용자들의 개선요구사항-기기 경량화, 유속 안정화, 자체점검기능, 저전력, 방수 및 방습-을 파악하여 반영함으로써 현장에 서 유량을 측정하기에 용이한 기기로 개발하였다.
        4,000원
        4.
        2018.10 KCI 등재 서비스 종료(열람 제한)
        In the industrial wastewater that occupies a large proportion of river pollution, the wastewater generated in textile, leather, and plating industries is hardly decomposable. Though dyeing wastewater has generally been treated using chemical and biological methods, its characteristics cause treatment efficiencies such as chemical oxygen demand (COD) and suspended solids (SS) to be reduced only in the activated sludge method. Currently, advanced oxidation technology for the treatment of dyeing wastewater is being developed worldwide. Electro-coagulation is highly adapted to industrial wastewater treatment because it has a high removal efficiency and a short processing time regardless of the biodegradable nature of the contaminant. In this study, the effects of the current density and the electrolyte condition on the COD removal efficiency in dyeing wastewater treatment by using electro-coagulation were tested with an aluminum anode and a stainless steel cathode. The results are as follows: ① When the current density was adjusted to 20 A/m2, 40 A/m2, and 60 A/m2 under the condition without electrolyte, the COD removal efficiency at 60 min was 62.3%, 72.3%, and 81.0%, respectively. ② The removal efficiency with NaCl addition was 7.9% higher on average than that with non-addition at all current densities. ③ The removal efficiency with Na2SO4 addition was 4.7% higher on average than that with non-addition at all current densities.