This study deals with the microstructure and tensile properties of 700 MPa-grade high-strength and seismic reinforced steel bars. The high-strength reinforced steel bars (600 D13, 600 D16 and 700 D13 specimens) are fabricated by a TempCore process, while the seismic reinforced steel bar (600S D16 specimen) is fabricated by air cooling after hot rolling. For specimens fabricated by the TempCore process, the 600 D13 and 600 D16 specimens have a microstructure of tempered martensite in the surface region and ferrite-pearlite in the center region, while the 700 D13 specimen has a microstructure of tempered martensite in the surface region and bainite in the center region. Therefore, their hardness is the highest in the surface region and shows a tendency to decrease from the surface region to the center region because tempered martensite has a higher hardness than ferrite-pearlite or bainite. However, the hardness of the 600S D16 specimen, which is composed of fully ferritepearlite, increases from the surface region to the center region because the pearlite volume fraction increases from the surface region to the center region. On the other hand, the tensile test results indicate that only the 700 D13 specimen with a higher carbon content exhibits continuous yielding behavior due to the formation of bainite in the center region. The 600S D16 specimen has the highest tensile-to-yield ratio because the presence of ferrite-pearlite and precipitates caused by vanadium addition largely enhances work hardening.
건축 구조물이 초고층화, 대형화, 특수화 되어감에 따라 고강도 재료의 사용이 증대되고 있으며, 고강도 재료가 사용된 철근콘크리트 보의 전단강도를 타당하게 예측할 수 있는 해석모델이 반드시 필요하다. 본 연구에서는 고강도 철근이 사용된 철근콘크리트 보의 전단강도를 타당하게 예측할 수 있는 트러스 모델을 제안한다. 고강도 철근이 사용된 철근콘크리트 보의 전단강도에 대한 제안된 모델인 TATM의 타당성을 검토하기 위하여 총 107개 보의 실험결과를 수집하였으며, TATM 및 기존 트러스 모델의 전단강도 해석결과를 이들 실험결과와 비교하였다. 비교 결과, TATM은 다른 트러스 모델보다 실험결과를 더 잘 예측하였으며, TATM의 해석결과에 대한 실험결과의 비는 인장철근과 전단 철근의 항복강도에 거의 관계없이 일정하였다.