검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 127

        41.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Membrane structure is a system that is stabilized by maintaining a tensile state of the membrane material that originally cannot resist the bending or pressure. Also, it is a system that allows the whole membrane structure to bear external loads caused by wind or precipitation such as snow, rain and etc. Tension relaxation phenomenon can transpire to the tension that is introduced to the fabric over time, due to the innate characteristics of the membrane material. Thus, it is important to accurately understand the size of the membrane tension after the completion of the structures, for maintenance and management purposes. The authors have proposed the principle of theoretically and indirectly measuring the tension by vibrating the membrane surface with sound waves exposures against the surface, which is compartmentalized by a rectangular boundary, and by measuring the natural frequency of the membrane surface that selectively resonates. The authors of this paper measured the tension of preexisting membrane structure for its maintenance by using the developed portable measurement equipment. Through analyzing the measurement data, the authors review the points that should be improved and the technical method for the new maintenance system of membrane tension.
        4,000원
        42.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        매년 증가하고 있는 풍해에 대한 대책으로서의 내풍설계는 필수적이다. 사과나무 지주시스템의 내풍설계를 위해서는 우선적으로 사과나무에 작용하는 풍하중을 파악해야 하고, 이를 위해서는 사과나무의 항력계수 산정이 필요하다. 기존 항력계수 산정 방법에서 발생할 수 있는 실험적 오차 등의 문제점을 보완하고자, 하중 측정 장치의 제작을 통한 풍하중 직접 측정 및 이를 통한 항력계수의 역추정 과정을 수행하였다. 풍속이 증가할수록 항력계수는 감소하며 점차 수렴하는 경향을 나타냈으며, 풍속 30m/s 일 때, 전면적 기준 약 0.176, 순면적 기준 약 0.356 의 값을 갖는 것으로 나타났다.
        4,000원
        44.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        전정안구반사(VOR; vestibulo-ocular reflex)는 머리가 움직이는 동안 안정된 망막상을 얻기 위해 일어나는 안구의 보상적 움직임이다. 망막정보와 전정신호가 감각갈등(sensory conflict)을 일으키면 멀미가 일어나며, VOR 이득(gain) 이 변한다는 것이 알려져 있다. 본 보고에서는 VOR을 측정할 수 있는 실용적이고 저렴한 시스템을 LabVIEW와 Arduino를 이용하여 구현하였다. 그리고 이 시스템을 사용하여 VOR의 특징적 변화를 두 가지 실험을 통해서 측 정하였다. 실험 1에서는 자기회전검사법을 이용하여 실험참가자(n = 4)의 수평 및 수직 전정안구반사의 특성을 살펴보았다. 실험 2에서는 가상환경 하에서 실험참가자(n = 8)가 정지된 화면을 볼 때와 사이버멀미(cybersickness)를 경험하는 3D 가상주행 영상에 노출되었을 때의 머리 움직임과 안구 운동을 측정하였다. 그 결과, 가상주행을 경험할 때 특징적인 머리 움직임과 안구 운동이 측정되었다. 본 보고에서 소개한 전정안구반사 측정 시스템은 가상환경에서의 사이버멀미 경감을 위한 심리생리학적 연구에 기여할 수 있을 것이다.
        4,300원
        45.
        2015.03 구독 인증기관 무료, 개인회원 유료
        This study is a development of a system for measuring the surface resistance of wafer and LCD by utilizing a three-axis positioner. Previous wafer measuring system is a developed product for measuring a wafer surface resistance. This is developed very long time. This is not a real action that it is needed a persistence development.. So, that is effected as weak point by simple mechanism and old software. This product is forecasted not being risen in world market. Therefore, this new product(surface measuring system by three axis positioner type) through this research is off the point a previous one axis revolute type, this new product is forecasted capable of a measurement not only wafer but also LCD.
        4,000원
        46.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The necessity of large-area and high-precision measurements has increased in industry area. The high-speed/high-precision multi probe measurement system has been developed to measure the 3D shape. The three different multi probes are combined in measurement system. This system is synchronized between the probes to measure the same position in the sample. Also this paper shows the measurement results with multi probe measurement system.
        4,000원
        47.
        2014.02 구독 인증기관 무료, 개인회원 유료
        Quality management system(QMS) made by international standard organization(ISO) for the testing and analysis bodies is increasingly required when countries trade their goods according to global trade regulations. This paper mentioned how to build the quality management system on domestic environmental measurement institutions and international trends on global environmental market. A conformity assessment system corresponded with the global standard and regulations has sharply been on the rise in all industrial fields as well as the environmental markets. Accordingly we should construct an appropriate QMS operation to promote analysis precision and spreading to all industrial sectors in order to survive on rapidly changing the current tendency of the times. Through this way, we can have global competitiveness. Especially, the settlement of a systematic and scientific quality assurance system is the key subject from the environmental analytical bodies to every societal industrial institutions.
        4,200원
        48.
        2013.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 지구물리 물리탐사 분야에서 경사각과 방위각 정보는 시추공 물리검층 및 물리탐사 자료보정을 위한 시추공 편차검층, 이동형 실시간 자료획득 시스템, 기타 지구물리 모니터링 시스템 등 다양하게 활용되면서 그 중요성이 높아지고 있다. 특히 최근 셰일가스의 개발이 가능하게 한 방향시추 기술에서도 경사각과 방위각 정보는 필수일 정도로 그 응용범위가 매우 넓다. 따라서 여러 분야에 응용될 수 있는 경사각과 방위각 측정 시스템의 초소형 옥외 저전력 운용이 절실해졌다. 본 논문에서는 최신 CMOS 저전력, 고성능 MCU 및 멤스(MEMS) 자세방위기준장치(AHRS)를 도입하여 초소형, 저전력으로 제작된 다용도 야외시험용 실시간 경사각과 방위각 연속 측정 시스템 개발 연구의 결과를 제시하고자 한다. 시스템은 최소 지름 42 mm의 존데 내에 설치될 수 있도록 초슬림 형태로 제작되었으며 실시간 데이터 획득이 가능할 뿐만 아니라 엔코더, DGPS 연동으로 운용 확장이 가능하여 다양한 응용이 기대된다.
        4,600원
        49.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study developed the pressure measurement monitoring system named VIP-2000 for monitoring a pressure of ullage space in cargo tank. VIP-2000 is designed in compliance with IMO(international maritime organization) SOLAS 74, Chap. II-2 Req. 59. IMO is providing the establishment of a pressure measurement equipment for secure the stability from vacuum or the overpressure that caused by in breakdown of the P/V valve. VIP-2000 operates the early warning of the visible and audibility in dangerous situation of cargo tank. In order to evaluate the performance of VIP-2000, the pressure measurement experiments have been conducted.
        4,000원
        50.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper studies the non-cutting optical fiber transmission tester, which can test the abnormality in the optical fiber core. The basic testing method, in the case of abnormality on the lines, can estimate the loss and other abnormalities by using optical power meter and stabilized laser source of light. The optical measurement wavelength of the system is the wavelength for communication of 1310, 1550nm, and can, in checking the abnormality on the communication lines, measure the optical in order not to affect the existing data communication network with the maximum loss of 0.5dB only. The break down can be diagnosed with the naked eyes by having red laser diode with optical power of 0.5mW(-3dBm) built-in.
        4,000원
        51.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Manufacturing companies' cost competitiveness with respect to equipment management can be achieved by satisfying additional market demands by their own capacity without purchasing additional equipments. In essence, it can be accomplished by making continu
        4,600원
        53.
        2010.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Oral squamous cell carcinoma (OSCC) has been a focus of cancer prevention studies due to the fact that it occurs by a multistep process and that a precancerous lesion in the oral mucosa is easily accessible. The present study was aimed at developing an optical detection system using autofluorescence spectrum measurements for the early detection of oral cancer. The optical detection system was designed to use an excitation wavelength of 337 nm emanating from a Xenon lamp. Precancerous and cancerous lesions were created in the hamster buccal pouch by treatment with 7,12-dimethylbenz[a]anthracene (DMBA). Four groups of five hamsters each were used in this experiment. The right buccal pouch was treated with 0.5% DMBA to induce carcinogenesis while the left buccal pouch was treated with mineral oil as a control. The autofluorescence of both buccal pouches was measured weekly. A difference in the excitation pattern between the normal and the carcinogen-treated tissue was noticed after three weeks. Specifically, the intensity of the autofluorescence spectrum in the DMBA-treated buccal pouch was increased at wavelengths between 400 and 450 nm. The results of the autofluorescence measurements were compared to histological findings and show that the intensity of the autofluorescence increased along with the stage of epithelial dysplasia. Based on the fact that one of the autofluorophores in this tissue is NADH, we measured the fluorescence at the 450-nm NADH wavelength to conclude that the increased autofluorescence in the dysplastic areas may be caused by NADH. Based on these data, we suggest that autofluorescence optical methods are a useful tool for the early detection of oral cancer.
        4,000원
        54.
        2010.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        선박에서의 주요한 진동발생 원인으로는 주기관과 프로펠러에 의한 것이다. 이러한 가진원으로부터 발생한 진동은 선박에 탑재된 장비의 내구성에 악영향을 미치고, 선박의 승조원에게도 불쾌감 등의 나쁜 영향을 미치게 된다. 본 연구에서는 선박에서 발생하는 진동을 계측하지 위한 시스템을 구축하였고 실제 실습선의 거주공간에서 발생하는 진동을 계측하였으며, 계측된 진동을 바탕으로 ISO6954:2000E에 의거하여 거주성 평가를 행하였다.
        4,000원
        56.
        2009.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 마샬 시험기를 이용하여 아스팔트 혼합물의 균열저항성을 평가할 수 있는 보다 간편하고 합리적인 측정시스템을 개발하는데 목적이 있다. 균열저항성 평가를 위한 파라메타로서 파괴에너지를 이용하였다. 마샬 시험기는 기본적으로 공시체 외부에 거치한 LVDT를 이용하여 수직변형률을 측정하는 시스템이며, 이 같은 외부 수직변형률 측정방식은 하중 스트랩 부분에서 발생하는 국부적인 변형으로 인해 측정오차를 야기할 가능성이 있다. 따라서 추가적인 계측 시스템을 설치하지 않고 기본적인 마샬 시험기를 이용하여 혼합물의 파괴에너지를 측정하기 위해서는 공시체 외부에 거치한 LVDT를 이용한 수직변형률 측정값이 파괴에너지 산정에 적용가능한지 여부를 검증하여야 한다. 이를 위해 본 연구에서는 공시체 중앙부분에서의 수평변형률과 외부에 거치한 LVDT를 이용한 수직변형률을 측정하는 두 가지 방식의 간접인장강도실험을 수행하여 그 차이를 비교 분석하였다. 실험결과, 외부 수직변형률 측정의 문제점으로 지적되었던 하중 스트랩 부분에서 발생하는 국부적인 변형은 파괴시점 이전에는 극히 적은 것으로 나타나 파괴에너지 계산에 오차를 유발하지 않음을 보여주었다. 또한 외부 수직변형률 측정의 실험변동성을 확인한 결과, 변동계수가 15% 이하로 마샬시험기를 이용한 균열저항성 평가시스템에 이용 가능함을 알 수 있었다.
        4,000원
        57.
        2008.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 언제 어디서나 건강관리를 할 수 있는 u-health care를 위해 cuff를 사용하지 않고 손쉽게 혈압을 측정할 수 있는 기술을 개발하였다. ECG와 PPG 시그널(signal) 만을 이용하여 혈압을 실시간으로 측정할 수 있는 기존 기술은 PTT를 분석 할 때 노이즈나 진폭의 변화로 인해 Peak 추정의 오류가 자주 발생한다. 본 연구에서는 이를 해결하기 위해 적응적 peak 추정 기술을 개발하여 Peak 추정의 정확도를 향상시켰다. 이를 적용하여 측정데이터를 분석한 결과 PTT의 표준편차는 28%감소하였으며, 노이즈 탐지 성능은 18%증가하였다. 또한 PTT와 혈압간의 상관성에 대해 분석한 결과 수축기 혈압= -0.044 · PTT + 133.592의 상관식을 도출하였다. 도출된 상관식을 적용하여 PPG와 ECG 만으로 수축기 혈압을 연속적으로 측정할 수 있는 시스템을 구축하였다.
        4,000원
        58.
        2008.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The present study contributes reviewing and suggesting various models for measurement system analysis (MSA). Measurement errors consist of accuracy, linearity, stability, part precision, repeatability and reproducibility (R&R). First, the major content presents split-plot design, and the combination method of crossed and nested design for obtaining gage R&R. Second, we propose x-s variable control chart for calculating the gage R&R and number of distinct category. Lastly, investigating the determination of gage performance curve which establishes the control specification propagating calibration uncertainties and measurement errors is described.
        4,000원
        59.
        2008.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Nowadays, BSC presented by alpan is observed by many enterprises and is being operated gradually. BSC includes non-financial factor as well as financial factor in performance assessment and it is a tool that will be able to evaluate even strategy of long-term view. In point of performance management, BSC brings in relief importance on non-financial performance as well as financial performance and it shares with viewpoint of 4 things of financial viewpoint, customer viewpoint, internal process view point, learning and growth viewpoint. then these make an array with vision and strategy of organization by causal relationship, it presented necessity of performance control on organization as center on KPI of inner of each viewpoint. Thus, study on measures and control of management performance is progressed actively and is accomplishing much development. This study is aimed at calculation of weight that is able to reflect its importance about AHP on KPI of each viewpoint. The purpose of this study is to present desirable performance measurement model and to give a weight in consideration of working-level character.
        4,000원
        60.
        2007.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        미고결, 난투수층 퇴적층 시료의 투수계수와 전기비저항의 측정이 가능한 삼축압력 측정장치를 설계하고 제작하였다. 이 측정장치는 측정셀 전후에 입출력 유량측정시스템이 설치되어 시료의 봉압을 증가시키면서 투수계수와 전기비저항을 동시에 측정할 수 있다. 아치의 법칙과 실험전후의 시료 질량 변화와 부피를 이용하여 공극률을 측정할 수 있다. 실험을 위한 시료는 표준모래와 일라이트 진흙을 성분비율을 다양하게 혼합한 인공시료와 동해 울릉분지에서 채취한 현장시료를 사용하였다. 이들 시료들에 대한 투수계수, 전기비저항을 봉압이 증가함에 따라 측정하고 분석하였다. 봉합이 증가함에 따라서 투수계수와 공극률은 지수적으로 감소하고 전기비저항은 지수적으로 증가한다.
        4,000원
        1 2 3 4 5