검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 215

        21.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, a twisted shape structure with an elevation form favorable to the resistance of vibration caused by wind loads is selected from among the forms of high-rise buildings. The analytical model is a square, triangular, and hexagonal plane with a plane rotation angle of one degree from 0 to 3 degrees per each story. As a result of the analysis, as the twist angle increased, story drift ratio is increased. Responses with different eccentricity rates were shown by analytical models. Therefore planar shapes designed symmetrically to the horizontal axis of X and Y are considered advantageous for eccentricity and torsion deformation. In the case of the bending moment of the column, the response was amplified in the column supporting the base floor, the roof floor, the floor in which the cross-section of the vertical member changes, and the floor having the same number of nodes as the base floor. Finally, the axial force response of the column is determined to be absolutely affected by the gravity load compared to the lateral load.
        4,000원
        22.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 논문에서는 박스형 전력구의 지진응답해석에 사용되는 응답진도법의 보수성을 평가하였다. 이를 위해 25가지 전력구 단면과 각 전력구에 대한 2개의 지반조건을 고려한 총 50개 예제를 선정하였다. 응답진도법의 보수성을 평가하기 위해 동적 지반-구조물 상호 작용을 고려한 정밀해석법에 의한 응답과 비교하였다. 비교결과, 정밀해석 응답에 대한 응답진도법에 의한 응답의 비로 정의한 응답 비의 평균이 1.0에 근접하며, 응답비의 표준편차도 5% 이내로 매우 작아서, 응답진도법에 의한 해석이 정밀해석법과 일관됨을 알 수 있었다. 마지막으로 응답진도법에 의한 응답에 하중계수 1.1을 적용하면 전력구의 보수적인 내진설계가 가능할 것으로 나타났다.
        4,000원
        23.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Seismic fragility analysis of a structure is generally performed for the expected critical component of a structure. The seismic fragility analysis assumes that all the components behave independently in a structural system. A bridge system consists of many inter-connected components. Thus, for an accurate evaluation of the seismic fragility of a bridge, the seismic fragility analysis requires the composition of probabilities considering the correlation between structural components. This study presented a procedure to obtain the seismic fragility curve of a bridge system, considering the correlation between bridge components. Seismic fragility analysis was performed on a PSC bridge that is considered as the central infrastructure. The analysis results showed that the probability of the seismic fragility curve of the bridge system was higher than that of each bridge component.
        4,000원
        24.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Nuclear power plants in Korea were designed and evaluated based on the NRC's Regulatory Guide 1.60, a design response spectrum for nuclear power plants. However, it can be seen that the seismic motion characteristics are different when analyzing the Gyeongju earthquake and the Pohang earthquake that has recently occurred in Korea. Compared to the design response spectrum, seismic motion characteristics in Korea have a larger spectral acceleration in the high-frequency region. Therefore, in the case of equipment with a high natural frequency installed in a nuclear power plant, seismic performance may be reduced by reflecting the characteristics of domestic seismic motions. The failure modes of the equipment are typically structural failure and functional failure, with an anchorage failure being a representative type of structural failure. In this study, comparative analyses were performed to decide whether to consider the inelastic behavior of the anchorage or not. As a result, it was confirmed that the seismic performance of the anchorages could be increased by considering the inelastic behavior of an anchorage.
        4,000원
        25.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The spatial variation characteristics of seismic motions at the nuclear power plant's site and structures were analyzed using earthquake records obtained at the Fukushima nuclear power plant during the Great East Japan Earthquake. The ground responses amplified as they approached the soil surface from the lower rock surface, and the amplification occurred intensively at about 50 m near the ground. Due to the soil layer's nonlinear characteristics caused by the strong seismic motion, the ground's natural frequency derived from the response spectrum ratio appeared to be smaller than that calculated from the shear wave velocity profile. The spatial variation of the peak ground acceleration at the ground surface of the power plant site showed a significant difference of about 0.6 g at the maximum. As a result of comparing the response spectrums at the basement of the structure with the design response spectrum, there was a large variability by each power plant unit. The difference was more significant in the Fukushima Daiichi site record, which showed larger peak ground acceleration at the surface. The earthquake motions input to the basement of the structure amplified according to the structure's height. The natural frequency obtained from the recorded results was lower than that indicated in the previous research. Also, the floor response spectrum change according to the location at the same height was investigated. The vertical response on the foundation surface showed a significant difference in spectral acceleration depending on the location. The amplified response in the structure showed a different variability depending on the type of structure and the target frequency.
        4,000원
        26.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 논문에서는 박스형 전력구의 지진응답해석에 사용되는 응답변위법(Response Displacement Method, RDM)의 보수성을 평가하였다. 이를 위하여 25가지 전력구 단면과 각 전력구에 대한 2개의 지반조건을 고려한 총 50개 예제를 선정하였다. 응답변위법에 의한 해석은 다음과 같은 세 가지 방법을 적용하였다: (1) 단일코사인방법, (2) 이중코사인방법, (3) 부지응답해석법. 그리고 이들 응답변위 법의 보수성을 평가하기 위하여 지반-구조물 상호작용을 고려한 동적해석법으로 구한 응답과 비교하였다. 비교결과, 설계지진력을 결정하는 방법 중에서 부지응답해석법이 가장 변동폭이 작았으며, 이중코사인방법이 가장 보수적인 결과를 보였다. 마지막으로 이중 코사인방법을 적용할 때, 응답변위법에 의한 부재력이 동적해석에 의한 값보다 클 확률이 80% 이상이 되기 위한 지반강성 보정계수 C값으로 기능수행수준에서 0.9, 붕괴방지수준에서 0.7을 추천하였다.
        4,300원
        27.
        2021.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Conditional spectra (CS) are applied to the seismic fragility assessment of a nuclear power plant (NPP) containment building for comparison with a relevant conventional uniform hazard response spectrum (UHRS). Three different control frequencies are considered in developing conditional spectra. The contribution of diverse magnitudes and epicentral distances is identified from deaggregation for the UHRS at a control frequency and incorporated into the conditional spectra. A total of 30 ground motion records are selected and scaled to simulate the probability distribution of each conditional spectra, respectively. A set of lumped mass stick models for the containment building are built considering nonlinear bending and shear deformation and uncertainty in modeling parameters using the Latin hypercube sampling technique. Incremental dynamic analysis is conducted for different seismic input models in order to estimate seismic fragility functions. The seismic fragility functions and high confidence of low probability of failure (HCLPF) are calculated for different seismic input models and analyzed comparatively.
        4,200원
        28.
        2021.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        원자력 발전소에 지진격리장치를 설치하여 내진성능을 향상시킬 수 있다. 그러나 지진격리장치의 적용으로 지반과 구조물 사이에서 큰 상대 변위가 발생하게 된다. 따라서 지진격리된 구조물과 일반 구조물을 연결하는 연결배관시스템의 경우 지진리스크가 증가할 수 있다. 따라서 이러한 배관시스템의 지진취약도를 분석할 필요가 있다. 본 연구에서는 지진취약도 분석 을 위해 지진격리된 APR1400 원자력발전소와 주증기관을 대상으로 지진취약도를 분석하였다. 주증기관은 지진격리된 nuclear island의 보조 건물과 터빈 건물을 연결하는 인터페이스 배관이다. 지진취약도 분석을 위한 파괴모드는 누출관통균열로 정의하였다. 누출은 실험결과와 수치해석을 통해 손상지수로 정량화하여 취약도 분석을 위한 파괴기준으로 사용하였다. 파괴기준의 변동에 의한 취약도 곡선의 변동성을 확인하기 위하여 손상지수의 최솟값, 최댓값, 평균값 및 중앙값을 파괴기준으로 하여 지진취약도 곡선을 작성하였다.
        4,200원
        29.
        2021.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the seismic safety of nuclear power plant structures is evaluated and verified by performing a vibration test on a relatively simple shear wall structure. The shear walls are the prominent members of nuclear power plants and resist the seismic load. The shear wall structure is designed and manufactured to perform shaking table tests and is used to increase the accuracy of the analytical method by comparing them with the numerical analysis results. Different results will be checked and more efficient application methods will be studied depending on the method of designing reinforced concrete structures.
        4,000원
        33.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A new lighting support structure composing of two-way wires and pulley, a pulley-type wireway system, was developed to improve the seismic performance of a ceiling type lighting equipment. This study verifies the seismic performance of the pulley-type wireway system using a numerical approach. A theoretical model fitted to the physical features of the newly-developed system was proposed, and it was utilized to compute a frictional coefficient between the wire and pulley sections under tension forces. The frictional coefficient was implemented to a finite element model representing the pulley-type wireway system. Using the numerical model, the seismic responses of the pulley-type wireway system were compared to those of the existing lighting support structure, a one-way wire system. The addition of the pulley component resulted in the increasement of energy absorption capacity as well as friction effect and showed in significant reduction in maximum displacement and oscillation after the peak responses. Thus, the newly-developed wireway system can minimize earthquake-induced vibration and damage on electric equipment.
        4,000원
        35.
        2020.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In seismic design standards such as KDS 41 17 00 and ASCE 7, three procedures are provided to estimate seismic demands: equivalent lateral force (ELF), response spectrum analysis (RSA), and response history analysis (RHA). In this study, two steel special moment frames (SMFs) were designed with ELF and RSA, which have been commonly used in engineering practice. The collapse probabilities of the SMFs were evaluated according to FEMA P695 methodology. It was observed that collapse probabilities varied significantly in accordance with analysis procedures. SMFs designed with RSA (RSA-SMFs) had a higher probability of collapse than SMFs designed with ELF (ELFSMFs). Furthermore, RSA-SMFs did not satisfy the target collapse probability specified in ASCE 7-16 whereas ELF-SMFs met the target probability.
        4,000원
        36.
        2020.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a field bridge test was conducted to find the dynamic properties of cable supported bridges with resilient-friction base isolation systems (R-FBI). Various ambient vibration tests were performed to estimate dynamic properties of a test bridge using trucks in a non-transportation state before opening of the bridge and by ordinary traffic loadings about one year later after opening of the bridge. The dynamic properties found from the results of the tests were compared with an analysis model. From the result of the ambient vibration tests of the cable supported bridge with R-FBI, it was confirmed that the dynamic properties were sensitive to the stiffness of the R-FBI in the bridge, and the seismic analysis model of the test bridge using the effective stiffness of the R-FBI was insufficient for reflecting the dynamic behavior of the bridge. In the case of cable supported bridges, the seismic design must follow the “Korean Highway Bridge Design Code (Limit State Design) for Cable supported bridges.” Therefore, in order to reflect the actual behavior characteristics of the R-FBI installed on cable-supported bridges, an improved seismic design procedure should be proposed.
        4,200원
        37.
        2020.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, studies have been actively conducted on seismic design and improvement of the seismic performance of bridges, buildings, factories, and plants. In particular, heavy items that are being manufactured or waiting to be shipped from factories (such as generators, engines, and boilers) must be equipped with seismic stoppers to prevent them from moving or falling during an earthquake. Seismic stoppers should be suitably determined by the size and weight of these heavy items; however, they have no general design standard. In this study, structural analyses and seismic tests were conducted to evaluate the performance of newly designed seismic stoppers. Structural analysis was performed on three stopper models to estimate the external load at which the yield stress of the material was not exceeded. Based on the analysis results, a seismic test of the stopper was carried out in accordance with the AC156 test method. Finally, product specifications for all three seismic stopper models were determined and their static/dynamic load performance was evaluated.
        4,000원
        38.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        우리나라는 지진에 대해 비교적 안전한 지역으로 인식되고 있었으나, 최근 경주지진과 포항지진이 발생하면서 시설물에 상당한 피해가 발생되면서 지진피해 저감장치를 적용한 내진설계 및 보강에 대한 연구와 개발이 수행되고 있다. 이미 건축된 구조물의 유지⋅보수에 대한 관심이 높아짐에 따라, 구조물의 감쇠, 강성 등을 국부적으로 변화시켜 지진 하중에 의한 에너지를 흡수하고 소산시키는 내진설계 방식인 제진기술이 활용되고 있다. 그러나 강한 지진이 발생할 때 제진 장치의 손상으로 인하여 사용성이 매우 떨어지게 되는 문제점이 발생되고 있다. 최근에는 이러한 문제를 해결하기 위해, 구조물의 가새 부재에 별도의 열처리를 하지 않고 응력 제거만으로 원형복원이 가능한 초탄성 형상기억합금을 적용하는 연구가 진행되고 있다. 따라서 본 연구에서는 비좌굴 가새 부재에 초탄성 형상기억합금을 사용하여 자동복원이 가능한 프레임 구조물을 구성하여 비선형 정적해석을 수행하여 구조물의 내진성능을 평가하고, 초탄성 형상기억합금의 재료적 특성의 우수성을 검증하고자 한다.
        4,000원
        39.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Seismic responses due to the dynamic coupling between a primary structure and secondary system connected to a structure are analyzed in this study. The seismic responses are compared based on dynamic coupling criteria and according to the error level in the natural frequency, with the recent criteria being reliant on the error level in the spectral displacement response. The acceleration responses and relative displacement responses of a primary structure and a secondary system for a coupled model and two different decoupled models of two degrees-of-freedom system are calculated by means of the time integration method. Errors in seismic responses of the uncoupled models are reduced with the recent criteria. As the natural frequency of the secondary system increases, error in the natural frequency decreases, but seismic responses of uncoupled models can be underestimated compared to that of coupled model. Results in this paper can help determine dynamic coupling and predict uncoupled models’ response conservatism.
        4,000원
        40.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The performance enhancement of various damping systems from natural hazards has become an highly important issue in engineering field. In this paper, ENTA hysteretic dampers were tested under cyclic loadings to evaluate their performance in terms of ductility and energy dissipation. The test results showed that the hysteretic dampers are effective damping systems to enhance the buildings performance for remodeling and retrofit of buildings. Also, the hysteretic dampers were modeled in FEM(Finite Element Method) structural analysis program. As comparing the computer modeling and the experiment, this study model reflects the nonlinear behavior of steel and derives the hysteresis loop.
        4,000원
        1 2 3 4 5