검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 419

        41.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A new lighting support structure composing of two-way wires and pulley, a pulley-type wireway system, was developed to improve the seismic performance of a ceiling type lighting equipment. This study verifies the seismic performance of the pulley-type wireway system using a numerical approach. A theoretical model fitted to the physical features of the newly-developed system was proposed, and it was utilized to compute a frictional coefficient between the wire and pulley sections under tension forces. The frictional coefficient was implemented to a finite element model representing the pulley-type wireway system. Using the numerical model, the seismic responses of the pulley-type wireway system were compared to those of the existing lighting support structure, a one-way wire system. The addition of the pulley component resulted in the increasement of energy absorption capacity as well as friction effect and showed in significant reduction in maximum displacement and oscillation after the peak responses. Thus, the newly-developed wireway system can minimize earthquake-induced vibration and damage on electric equipment.
        4,000원
        42.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper is to investigate the retrofitting effect for a non-seismic reinforced concrete frame strengthened by perimeter steel moment frames with indirect integrity, which ameliorates the problems of the direct integrity method. To achieve this, first, full-scale tests were conducted to address the structural behavior of a two-story non-seismic reinforced concrete frame and a strengthened frame. The non-seismic frame showed a maximum strength of 185 kN because the flexural-shear failure at the bottom end of columns on the first floor was governed, and shear cracks were concentrated at the beam-column joints on the second floor. The strengthened frame possessed a maximum strength of 338 kN, which is more than 1.8 times that of the non-seismic specimen. A considerable decrease in the quantity of cracks for the strengthened frame was observed compared with the non-seismic frame, while there was the obvious appearance of the failure pattern due to the shear crack. The lateral-resisting capacity for the non-seismic bare frame and the strengthened frame may be determined per the specified shear strength of the reinforced columns in accordance with the distance to a critical section. The effective depth of the column may be referred to as the longitudinal length from the border between the column and the foundation. The lateral-resisting capacity for the non-seismic bare frame and the strengthened frame may be reasonably determined per the specified shear strength of the reinforced columns in accordance with the distance to a critical section. The effective depth of the column may be referred to as the longitudinal length from the border between the column and the foundation. The proposed method had an error of about 2.2% for the non-seismic details and about 4.4% for the strengthened frame based on the closed results versus the experimental results.
        4,000원
        43.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper examines the seismic performance and structural design of the ceiling bracket-type modular connection. The bracket-type system reduces the cross-sectional area loss of members and combines units using fitting steel plate, and it has been developed to be fit for medium-story and higher-story buildings. In particular, this study conducted the cyclic loading test for the performance of the C-type and L-type brackets, and compared the results. The test results were also compared with the commercial FEA program. In addition, the structural design process for the bracket-type modular connection was presented. The two connections, proposed as a result of the test results, were all found to secure the seismic performance level of the special moment steel frame. In the case of initial stiffness, the L-type bracket connection was found to be great, but in the case of the maximum moment or fully plastic moment, it was different depending on the loading direction.
        4,000원
        44.
        2020.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In a previous paper, ambient vibration tests were conducted on a cable stayed bridge with resilient-friction base isolation systems (R-FBI) to extract the dynamic characteristics of the bridge and compare the results with a seismic analysis model. In this paper, a nonlinear seismic analysis model was established for analysis of the bridge to compare the difference in seismic responses between nonlinear time history analysis and multi-mode spectral analysis methods in the seismic design phase of cable supported bridges. Through these studies, it was confirmed that the seismic design procedures of the “Korean Highway Bridge Design Code (Limit State Design) for Cable Supported Bridges” is not suitable for cable supported bridges installed with R-FBI. Therefore, to reflect the actual dynamic characteristics of the R-FBI installed on cable-supported bridges, an improved seismic design procedure is proposed that applies the seismic analysis method differently depending on the seismic isolation effect of the R-FBI for each seismic performance level.
        4,000원
        45.
        2020.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a field bridge test was conducted to find the dynamic properties of cable supported bridges with resilient-friction base isolation systems (R-FBI). Various ambient vibration tests were performed to estimate dynamic properties of a test bridge using trucks in a non-transportation state before opening of the bridge and by ordinary traffic loadings about one year later after opening of the bridge. The dynamic properties found from the results of the tests were compared with an analysis model. From the result of the ambient vibration tests of the cable supported bridge with R-FBI, it was confirmed that the dynamic properties were sensitive to the stiffness of the R-FBI in the bridge, and the seismic analysis model of the test bridge using the effective stiffness of the R-FBI was insufficient for reflecting the dynamic behavior of the bridge. In the case of cable supported bridges, the seismic design must follow the “Korean Highway Bridge Design Code (Limit State Design) for Cable supported bridges.” Therefore, in order to reflect the actual behavior characteristics of the R-FBI installed on cable-supported bridges, an improved seismic design procedure should be proposed.
        4,200원
        52.
        2020.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, studies have been actively conducted on seismic design and improvement of the seismic performance of bridges, buildings, factories, and plants. In particular, heavy items that are being manufactured or waiting to be shipped from factories (such as generators, engines, and boilers) must be equipped with seismic stoppers to prevent them from moving or falling during an earthquake. Seismic stoppers should be suitably determined by the size and weight of these heavy items; however, they have no general design standard. In this study, structural analyses and seismic tests were conducted to evaluate the performance of newly designed seismic stoppers. Structural analysis was performed on three stopper models to estimate the external load at which the yield stress of the material was not exceeded. Based on the analysis results, a seismic test of the stopper was carried out in accordance with the AC156 test method. Finally, product specifications for all three seismic stopper models were determined and their static/dynamic load performance was evaluated.
        4,000원
        53.
        2020.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Analysis of the 2016 Gyeongju earthquake and the 2017 Pohang earthquake showed the characteristics of a typical high-frequency earthquake with many high-frequency components, short time strong motion duration, and large peak ground acceleration relative to the magnitude of the earthquake. Domestic nuclear power plants were designed and evaluated based on NRC's Regulatory Guide 1.60 design response spectrum, which had a great deal of energy in the low-frequency range. Therefore, nuclear power plants should carry out seismic verification and seismic performance evaluation of systems, structures, and components by reflecting the domestic characteristics of earthquakes. In this study, high-frequency amplification factors that can be used for seismic verification and seismic performance evaluation of nuclear power plant systems, structures, and equipment were analyzed. In order to analyze the high-frequency amplification factor, five sets of seismic time history were generated, which were matched with the uniform hazard response spectrum to reflect the characteristics of domestic earthquake motion. The nuclear power plant was subjected to seismic analysis for the construction of the Korean standard nuclear power plant, OPR1000, which is a reactor building, an auxiliary building assembly, a component cooling water heat exchanger building, and an essential service water building. Based on the results of the seismic analysis, a high-frequency amplification factor was derived upon the calculation of the floor response spectrum of the important locations of nuclear power plants. The high-frequency amplification factor can be effectively used for the seismic verification and seismic performance evaluation of electric equipment which are sensitive to high-frequency earthquakes.
        4,000원
        54.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        경주지진과 포항지진으로 수도관 파열과 상수도관 누수가 보고되었다. 따라서 상수도 시설의 지진안전성 확보는 지속적이고 안정적인 물공급을 위하여 중요한 이슈이다. 상수도관은 주로 도로 하부나 일반 성토지반에 매설되어있기 때문에 지진파에 의한 변형뿐만 아니라, 지반의 영구변형, 사면의 불안정성 및 지반 액상화 등에 의한 배관의 굽힘 변형이 발생하게 된다. 이러한 배관의 굽힘 변형이 과도하게 발생 되면 배관 이음부 변위허용량을 초과하여 손상 및 누수로 이어지게 된다. 따라 서, 상수도관 이음부의 허용 변형각이 산출되어야 지진으로 인한 지반의 변형에 대하여 상수도관의 지진안전성을 정확하게 평가할 수 있다. 상수도 시스템은 현장 상황과 설치 여건에 따라 다양한 종류의 상수도관을 이용하고 있다. 그중 주철 상수도관은 오랜 기간 사용되고 개선되어 일반적으로 널리 사용되고 있다. 본 연구에서는 한국주철관공업(주)에서 제작한 EZ-LOK 조인트가 적용된 주철 상수도관에 대하여 4점 굽힘시험을 수행하였으며, 매설된 주철 상수도관의 내진 및 내침하 설계기준인을 참조하여 지진안전성을 평가하였다.
        4,000원
        55.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        우리나라는 지진에 대해 비교적 안전한 지역으로 인식되고 있었으나, 최근 경주지진과 포항지진이 발생하면서 시설물에 상당한 피해가 발생되면서 지진피해 저감장치를 적용한 내진설계 및 보강에 대한 연구와 개발이 수행되고 있다. 이미 건축된 구조물의 유지⋅보수에 대한 관심이 높아짐에 따라, 구조물의 감쇠, 강성 등을 국부적으로 변화시켜 지진 하중에 의한 에너지를 흡수하고 소산시키는 내진설계 방식인 제진기술이 활용되고 있다. 그러나 강한 지진이 발생할 때 제진 장치의 손상으로 인하여 사용성이 매우 떨어지게 되는 문제점이 발생되고 있다. 최근에는 이러한 문제를 해결하기 위해, 구조물의 가새 부재에 별도의 열처리를 하지 않고 응력 제거만으로 원형복원이 가능한 초탄성 형상기억합금을 적용하는 연구가 진행되고 있다. 따라서 본 연구에서는 비좌굴 가새 부재에 초탄성 형상기억합금을 사용하여 자동복원이 가능한 프레임 구조물을 구성하여 비선형 정적해석을 수행하여 구조물의 내진성능을 평가하고, 초탄성 형상기억합금의 재료적 특성의 우수성을 검증하고자 한다.
        4,000원
        56.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A corrugated steel plate wall (CSPW) system is advantageous to secure the strength and stiffness required for lateral force resistance because of its high out-of-plane stability. It can also stably dissipate large amounts of energy even after peak strength. In this paper, a preliminary study has been carried out to use the CSPW system in the seismic retrofit of existing reinforced concrete (RC) moment frame buildings. The seismic performance for an example building was evaluated, and then a step-by-step retrofit design procedure for the CSPW was proposed. An equivalent analytical model of the CSPW was also introduced for a practical analysis of the retrofitted building, and the strengthening effect was finally evaluated based on the results of nonlinear analysis.
        4,000원
        57.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The performance enhancement of various damping systems from natural hazards has become an highly important issue in engineering field. In this paper, ENTA hysteretic dampers were tested under cyclic loadings to evaluate their performance in terms of ductility and energy dissipation. The test results showed that the hysteretic dampers are effective damping systems to enhance the buildings performance for remodeling and retrofit of buildings. Also, the hysteretic dampers were modeled in FEM(Finite Element Method) structural analysis program. As comparing the computer modeling and the experiment, this study model reflects the nonlinear behavior of steel and derives the hysteresis loop.
        4,000원
        58.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Nonlinear static analysis and preliminary evaluation were performed in this study to evaluate the seismic performance of unreinforced masonry buildings subjected to various soil conditions based on the revised Korean Building Code. Preliminary evaluation scores and nonlinear static analyses indicated that all buildings were susceptible to collapse and did not reach their target performance. Therefore, retrofit of those building models was carried out through a systematic procedure to determine areas to be strengthened. It was possible to make most building models satisfy performance objectives through the reinforcement alone of damaged external shear walls. However, the application of a preliminary evaluation procedure to retrofit design was found to be too conservative because all the retrofitted building models verified with nonlinear static analysis failed to satisfy performance objectives. Therefore, it is possible to economically retrofit unreinforced masonry buildings through the fortification of external walls if a simple evaluation procedure that can efficiently specify vulnerable parts is developed.
        4,000원
        60.
        2020.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 국내에서 발생한 경주지진 및 포항지진이 도심지 및 원자력발전소 주변에서 발생함에 따라 인근 주요 구조시스 템에 피해를 발생시킨 바 있다. 이에 따라, 본 연구는 원전 배관계통의 지진 거동 특성을 실험 및 해석적으로 규명하고, 이를 바탕으로 내진성능을 평가하는 연구를 수행하는 것을 목적으로 한다. 이를 위하여, 원전 배관계통을 대상으로 한 진동대 시험 결과를 바탕으로 배관 수치해석 모델을 수립하고 이를 시험 결과를 통하여 검증한다. 또한, 이러한 검증된 수치해석모델을 기반으로 배관계통의 내진성능을 평가한다. 수치해석 모델 검증 결과, 수립된 수치모델의 고유진동수, 감쇠비 및 변위 응답이 진동 대시험 결과와 유사한 것으로 나타났다. 이러한 검증된 수치모델을 바탕으로 평가된 내진성능 값은 기존 원전 배관의 내진성능 값의 범위와 비교적 유사한 값으로 평가되었다. 이는 설계기준지진을 크게 상회하는 값이지만, 원전 주요 기기 임을 감안할 때 추가적인 내진성능 상향이 확보되면 원전 지진 안전성 향상에 많은 기여를 할 수 있을 것으로 판단된다. 본 연구의 결과는 추후 원전 배관계통 내진성능평가를 위한 정량적인 자료로 활용이 가능할 것으로 판단된다.
        4,000원
        1 2 3 4 5