검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 6

        2.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Solar energy has been known as a successful alternative energy source, however it requires a large area to build power generation facilities compared to other energy sources such as nuclear power. Weather factors such as rainy weather or night time impact on solar power generation because of lack of insolation and sunshine. In addition, solar power generation is vulnerable to external elements such as changes in temperature and fine dust. There are four seasons in the Republic of Korea hereby variations of temperature, insolation and sunshine are broad. Currently factors that cause find dust are continuously flowing in to Korea from abroad. In order to build a solar power plant, a large area is required for a limited domestic land hereby selecting the optimal location for the plant that maximizes the efficiency of power generation is necessary. Therefore, this research analyze the optimal site for solar power generation plant by implementing analytic hierarchy process based on weather factors such as fine dust. In order to extract weather factors that impact on solar power generation, this work conducts a case study which includes a correlation analysis between weather information and power generation.
        4,200원
        3.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        비순환식 고형배지경에서 배액이 토양과 지하수 오염을 발생시키는 문제를 해결하고자 그동안 연구된 데이터를 바탕으로 배액 최소화 재배방식을 확립을 위해 본 연구는 토마토 코이어 수경재배농가 시설에서 FDR 센서, 적산일사량 센서 및 타이머를 이용하여 토마토를 재배하며 급배액량, 생육 및 생산량을 비교하였다. 정식 후 88일까지 일일 식물체당 평균 급액량은 처리구에 따른 큰 차이가 없었다. 하지만 정식 후 88일 이후 107일 까지 TIMER, FDR, IR 제어구 각각의 일일 식물체당 평균 급액량은 IR(2125mL) > TIMER(2063mL) > FDR(1983mL) 수준이었고 108일부터 120일 까지는 IR(2000mL) > TIMER(1664mL) > FDR(1500mL) 수준 이었다. 배액률은 TIMER 제어구의 경우 5~12%, FDR 센서 제어구의 경우 0~7%, IR 제어구의 경우 12~19% 수준으로 IR > TIMER > FDR 순이었다. 정식 후 88일 이후부터는 FDR과 IR 제어구가 급액량에 상이한 결과를 보였는데, 이는 재배 후기 즉, 5월 20일 이후 (정식 후 94일) 누적일사량의 증가로, IR 제어구에서는 급액이 증가된 반면 FDR 센서 처리구는 적심 이후 30일이 경과된 6월 2일경부터 IR 제어구 보다 일일 급액량이 평균 500mL 적게 공급된 결과이다. 식물체 생육 및 상품과 수량도 급액방식에 따른 통계적 유의차는 없었지만, 당도는 FDR 처리구에서 TIMER 처리구에 비해 약 11%, IR 처리구에 비해 약 18% 높았다.
        4,000원
        4.
        2015.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서 순천만 일대 새우 양식장 부근에서 이뤄지는 태양광 발전에 따른 소음영향평가방법을 진단하였다. 순천만 폐양식장에 태양광 발전시설이 설치되는 경우, 임계거리 17미터 이내에 위치한 새우양식장 S₂와 S₃(15미터 이격)은 소음에 대한 저감대책을 수립하지 않은 상태로 작업할 경우에는 악영향이 나타날 수 있다. 소음 스트레스를 감소시키기 위해 방음 판넬을 설치할 시, 본 연구에서 고려한 공사장비 최저효율(Case A), 일반효율(Case B), 최고효율(Case C)에 대한 수중소음 환경목표기준을 만족하는 것으로 나타났다. 건설 장비에서 발생되는 대기 소음이 수중으로 전파될 경우, 보다 합리적인 계산을 통해 수중 소음도 예측과 함께 주변 양식장에 미치는 누적 영향에 대한 심도 있는 평가 및 대책 수립이 필요하다.
        4,000원
        5.
        2013.05 구독 인증기관 무료, 개인회원 유료
        This paper presents a development process of a forecast and monitoring system for a photovoltaic (PV) solar plant. PV solar system is one of sustainable resource of energy. So, Korean government encourages businessmen to build a PV solar plant. Renewable Portfolio Standard (RPS) system is one of encouraging policies. Most RPS businessmen use monitoring system for a PV solar plant and they need an accurate forecast of power generation for business purpose. Therefore we propose an estimating algorithm of power for a PV solar plant using weather forecast. Proposed algorithm is implemented in a forecast and monitoring system and it works better than existing estimating methods.
        4,000원
        6.
        2019.05 KCI 등재 서비스 종료(열람 제한)
        In this study, a solar light collector that collects and transmits solar light required for crop production in a closed plant production system was developed. The solar light collector consisted of a Fresnel lens for collecting solar light, and a tracking actuator for tracking solar light from sunrise to sunset to increase the light collection efficiency. The optical fiber that transmitted solar light was made of Glass Optical Fiber (GOF), and it had an excellent optical transmission rate. After collecting the solar light, the amount of light was measured at 5, 10, 15, 20, 25, and 30 cm distances from the GOF through the darkroom by using a light sensor logger connected to a quantum and pyranometer sensor. Compared with solar light, the light intensity of pyranometer sensor measured at 5 cm was 114% higher than solar light, and 61% at 10 cm. In addition, it was observed that it is possible to transmit the necessary amount of light for growing crops up to about 15 cm (as over 22%) through GOF. Therefore, adding diffusers to the solar light collector should be expected to replace artificial light in plant factories or plug seedlings nurseries for leafy vegetables. More studies on the solar light collection devices and the light transmission devices that have high light collection efficiency should be conducted.