검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 1,347

        1.
        2024.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Piloti-type structures with vertical irregularity are vulnerable to earthquakes due to the soft structure of the first story. Structural characteristics of buildings can significantly affect the seismic loss function, calculated based on seismic fragility, and therefore need to be considered. This study investigated the effects of the number of stories and core locations on the seismic loss function of piloti-type buildings in Korea. Twelve analytical models were developed considering two variations: three stories (4-story, 5-story, and 6-story) and four core locations (center core, x-eccentric core, y-eccentric core, and xy-eccentric core). The interstory drift ratio and peak floor acceleration were assessed through incremental dynamic analysis using 44 earthquake records, and seismic fragility was derived. Seismic loss functions were calculated and compared using the derived seismic fragility and repair cost ratio of each component. The results indicate that the seismic loss function increases with more stories and when the core is eccentrically located in the piloti-type structure model. Therefore, the uncertainty due to the number of stories and core location should be considered when deriving the seismic loss function of piloti-type structures.
        4,000원
        2.
        2024.04 구독 인증기관·개인회원 무료
        본 연구에서는 탄소나노튜브(CNT) 패치 센서를 기반으로 하여 구조물의 이상 거동을 감지하고 대 응할 수 있도록 하는 첨단 스마트 모니터링 시스템을 제안한다. 복합소재로 제작되는 CNT 센서는 유 연한 특성을 갖게 되어 다양한 형태의 구조물 표면에 적용할 수 있으며, 이를 통해 충격이나 피로 등 에 의해 발생되는 균열과 같은 비정상적인 거동을 감지할 수 있다. CNT 센서를 통해 수집한 데이터 는 IoT 시스템을 통해 실시간으로 분석되어 구조물의 거동 상태를 확인하고 건전성을 모니터링 할 수 있게 한다. 이 시스템의 성능 검증 및 사용성 검토를 위해 미국 소재 교량에서 실증 테스트를 하였으 며, 테스트 결과 CNT 센서를 이용한 구조물 거동 감지 시스템을 통해 구조물의 이상 거동을 효과적 으로 감지하고 모니터링하여 구조물에서 발생 될 수 있는 잠재적 문제를 사전에 예방할 수 있음을 확 인하였다. 이와 같은 기술은 추후 다양한 분야에서 적극적으로 활용될 수 있을 것으로 기대된다.
        3.
        2024.04 구독 인증기관·개인회원 무료
        해양 부유식 구조물의 계류시설에 대한 연구는 다양한 계류 시스템의 개발과 그 효율성에 대해 지 속적으로 연구되어 왔다. 계류 시스템은 구조물의 안전성, 내구성, 그리고 환경적인 책임을 모두 고려 해야하는 복합적인 설계 요소이다. 기존 계류바익은 해저지반의 특성에 크게 의존하며, 넓은 점유 면 적으로 인해 해양환경과 활동에 부정적인 영향을 줄 수 있다. 이러한 기존 계류시스템의 한계와 문제 점에 대응하기 위해, 본 연구에서는 새로운 계류시스템을 제안하고자 한다. 제안된 계류시스템은 계류 선이 해저지반에 고정되지 않고 중력식 기초 구조물을 거쳐 중간부력재에 연결된다. 중간 부력재는 상 시 과잉 부력상태로 상향력이 작용하며, 이로인해 계류선에 초기장력이 유도되며 전체 시스템에 강성 을 도입한다. 전체적으로 Semi-taut과 유사한 방식으로 계류 장력 변화에 따른 상단 플랫폼의 운동 제어와, 중간 부력재와의 상호연계 거동효과로 추가적인 동적 응답 저감이 기대된다. 본 연구에서는 제안된 신형식 계류시스템의 역학적 거동특성을 수치해석적으로 구현하고 파랑에 대한 Catenary system 대비 운동 저감 성능을 검증하였다.
        4.
        2024.03 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        This work focuses on the fabrication of excellent magnetic structures for trapping breast cancer cells. Micromagnetic structures were patterned for trapping cancer cells by depositing 30 nm of permalloy on a silicon substrate. These structures were designed and fabricated using two fabrication techniques: electron beam lithography and laser direct writing. Two types of magnetic structures, rectangular wire and zig-zagged wire, were created on a silicon substrate. The length of each rectangular wire and each straight line of zig-zagged wire was 150 μm with a range of widths from 1 to 15 μm for rectangular and 1, 5, 10 and 15 μm for zigzag, respectively. The magnetic structures showed good responses to the applied magnetic field despite adding layers of silicon nitride and polyethylene glycol. The results showed that Si + Si3N4 + PEG exhibited the best adhesion of cells to the surface, followed by Si + Py + Si3N4 + PEG. concentration of 5-6 with permalloy indicates that this layer affected silicon nitride in the presence of Polyethylene glycolPEG.
        4,000원
        5.
        2024.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Code-compliant seismic design should be essentially applied to realize the so-called emulative performance of precast concrete (PC) lateral force-resisting systems, and this study developed simple procedures to design precast industrial buildings with intermediate precast bearing wall systems considering both the effect of seismic and blast loads. Seismic design provisions specified in ACI 318 and ASCE 7 can be directly adopted, for which the so-called 1.5S y condition is addressed in PC wall-to-wall and wall-to-base connections. Various coupling options were considered and addressed in the seismic design of wall-to-wall connections for the longitudinal and transverse design directions to secure optimized performance and better economic feasibility. On the other hand, two possible methods were adopted in blast analysis: 1) Equivalent static analysis (ESA) based on the simplified graphic method and 2) Incremental dynamic time-history analysis (IDTHA). The ESA is physically austere to use in practice for a typical industrial PC-bearing wall system. Still, it showed an overestimating trend in terms of the lateral deformation. The coupling action between precast wall segments appears to be inevitably required due to substantially large blast loads compared to seismic loads with increasing blast risk levels. Even with the coupled-precast shear walls, the design outcome obtained from the ESA method might not be entirely satisfactory to the drift criteria presented by the ASCE Blast Design Manual. This drawback can be overcome by addressing the IDTHA method, where all the design criteria were fully satisfied with precast shear walls’ non-coupling and group-coupling strength, where each individual or grouped shear fence was designed to possess 1.5S y for the seismic design.
        4,000원
        6.
        2024.02 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        The lightweight and high strength characteristics of aluminum alloy materials make them have promising prospects in the field of construction engineering. This paper primarily focuses on aluminum alloy materials. Aluminum alloy was combined with concrete, wood and carbon fiber reinforced plastic (CFRP) cloth to create a composite column. The axial compression test was then conducted to understand the mechanical properties of different composite structures. It was found that the pure aluminum tube exhibited poor performance in the axial compression test, with an ultimate load of only 302.56 kN. However, the performance of the various composite columns showed varying degrees of improvement. With the increase of the load, the displacement and strain of each specimen rapidly increased, and after reaching the ultimate load, both load and strain gradually decreased. In comparison, the aluminum alloy-concrete composite column performed better than the aluminum alloy-wood composite column, while the aluminum alloy-wood-CFRP cloth composite column demonstrated superior performance. These results highlight excellent performance potential for aluminum alloy-wood-CFRP composite columns in practical applications.
        4,000원
        7.
        2024.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, infrared thermometry techniques were used to conduct surface wetting performance tests (wicking tests) on micropillar structures with good fluid supply capabilities to enhance the critical heat flux. Wicking tests were conducted based on various micropillar shapes (i.e., diameter and spacing) to investigate the surface wetting performance near the boiling point of the fluid(~100°C). The surface temperature was increased from 20°C to 95°C, to examine the wicking performance The shape of the micropillars were quantified by the roughness and the effect of the roughness and temperature on the wicking performance was analyzed. As a result, we confirmed that the roughness of the micropillars increases the capillary pressure, improving the wicking performance. The sample D04 G10 with the highest roughness coefficient at room temperature (r=2.51) exhibited the highest wicking coefficient, showing a 170% improvement in wicking performance compared to D04G20 with the smallest roughness coefficient at room temperature(r=1.51). Additionally, the D04 G10 sample (r=2.51) recorded a 50% improvement in the wicking coefficient at the highest temperature(95°C) compared to room temperature(20°C). The wicking coefficient data will be utilized as a database for developing a new correlation for critical heat flux.
        4,000원
        8.
        2024.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 분리막 생물반응기(membrane bioreactor, MBR)에서 발생되는 생물막오염 완화에 탁월한 효과를 가진 분리막을 개발할 목적으로, 친수성 산소 기능기가 많은 탄소나노구체(carbon nanosphere, CNS)를 합성한 뒤, 이를 첨가 제로 활용하여 친수성과 다공성 기공 구조를 갖는 고성능 한외여과막을 제조하였다. CNS는 막 표면에 초승달 모양의 기공을 형성하였고, CNS 함량을 4.6 wt%까지 증가시킴에 따라 최대기공 크기보다 큰 결함을 야기하지 않으면서 평균 표면 기공 크 기를 약 40% 증가시키는 것으로 나타났다. 또한, CNS 복합막의 다공성 기공 구조는 CNS의 등방성 형태와 상대적으로 낮은 입자 수밀도 덕분에 CNS 첨가에 따른 고분자 용액의 점도 급등이 방지됐기 때문이라고 판단된다. 그러나 너무 다공성이 커 지게 되면 기계적 물성이 저하되므로, 기공구조와 기계적 성질을 포함한 종합적인 고려를 했을 때 CNS2.3이 가장 우수하다 고 관측되었다. CNS2.3은 CNS0에 비해 수투과도가 2배 이상 높을 뿐만 아니라, MBR 공정에서 분리막 세정이 요구될 때까 지의 운전 시간도 5배 이상 연장시킨 것으로 확인되었다.
        4,300원
        9.
        2024.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 인접국가인 일본에서 규모 7.6의 지진이 발생하였다. 이 지진은 대규모의 최초 지진 이후 120회 이상의 여진을 동반하여 지진의 위험성이 두각되었다. 실제로 구조물들은 최초 지진이후 항복하여 지속되는 여진에 의해서도 붕괴될 위험이 있기 때문에 지진 저항력을 향상시킬 필요가 있다. 본 연구에서는 자동복원이 가능한 신소재를 활용하여 지진에 의한 피해를 감소시키면서도 댐퍼와 구조물에 발생되는 잔류변위를 회복시킬 수 있는 자동복원 신소재 댐퍼를 제안한다. 이 댐퍼는 초탄성 형상기억합금과 폴리우레탄으로 구성되며 폴리우레탄에는 선행압축이 적용되어 그로 인한 반발력을 통해 회복특성을 증진시킨 다. 이에 대한 성능을 평가하기 위해 구조실험과 구조실험에 대한 수치해석을 진행하여 댐퍼의 회복특성, 하중특성을 확인하였 다. 또한, OpenSEES프로그램을 활용하여 구조물에 댐퍼를 적용시키고 실제 지진환경에 대한 수치해석을 수행함으로써 지붕변 위, 밑면 전단력 등의 응답을 구하여 자동복원 신소재 댐퍼의 우수성을 검증하였다. 이를 통해 자동복원 신소재 댐퍼를 구조물 에 적용하게 되면 국내 역대 지진 중 가장 규모가 큰 지진이 다시 발생하여도 구조물을 다시 회복할 수 있을 것으로 기대된다.
        4,000원
        10.
        2024.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 기존 (불)투과형 사방댐의 부식 및 시공성 등의 문제를 보완하고자 GFRP와 CFRP를 사용하여 내부식성 투과형 사방댐을 설계한 선행연구의 후속 연구로써 FRP로 제작된 격자형 사방 구조물(Grid)을 설계하여 탈부착이 가능한 투과 형 사방댐을 개발하기 위한 기초 연구이다. 이를 위해 탄소산업진흥원(K-Carbon)의 상용 Grid 제원을 인용하였으며, Grid를 구성 하는 띠(Strip)는 41×21개로 총 4000×2000×1.5 mm의 크기로 설계하였다. Grid의 개발을 위한 기초 연구라는 특성상 Grid의 지지 부(Slot)와 충진재는 파괴되지 않는다고 가정하였으며, FRP의 파괴 이론인 Hashin Damage Criteria에 따라 Grid의 설계하중 작용 시의 안전성을 상용 유한요소해석 프로그램인 ABAQUS로 평가하였다. 그 결과, 0.01~0.03sec 내에서 GFRP와 CFRP Grid가 파괴 되었으며, 이는 Grid의 성능이 충분하지 못함을 의미한다. 이에 따라 Grid의 성능 향상을 위해서 GFRP 및 CFRP(면재)와 Balsa Wood(심재)로 구성된 Sandwich Grid를 개발하였으며, 동일 조건에서 해석을 수행한 결과, Grid 대비 Sandwich Grid가 약 126~140 배 뛰어난 성능을 보였다. 결론적으로 Sandwich Grid를 이용한 탈착형 사방댐은 내구성 및 경제성 측면에서 이점이 분명하다 판 단되지만, 이는 일부 가정 사항과 수치 해석을 기반으로 하는 결과이므로 향후 추가 연구가 수행되어야 할 필요가 있다.
        4,000원
        11.
        2024.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        By developing molds and facilities to horizontally mold the functional part of the dry-cast concrete block, We intend to develop molds and a series of facilities to horizontally mold the functional part of the dry-cast concrete block to increase production per cycle while maintaining existing production methods and major facilities. In order to do so, CAE analysis is first required to develop molds and facilities for horizontally molding the functional part of the drycast concrete block in the horizontal direction. The procedure will be carried out by reviewing the validity of boundary conditions and physical properties, 3D modeling, grid generation, construction of analysis models, model validity, analysis according to frequency changes, and analysis according to physical properties. First, through the comparison of two-point support, three-point support, and two-point and three-point support in the constraint conditions, We would like to compare it with the actual molded product in the horizontal direction. But first of all, it is considered two-point support in the constraint conditions in this paper.
        4,300원
        12.
        2024.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, in newly constructed apartment buildings, the exterior wall structures have been characterized by thinness, having various openings, and a significantly low reinforcement ratio. In this study, a nonlinear finite element analysis was performed to investigate the crack damage characteristics of the exterior wall structure. The limited analysis models for a 10-story exterior wall were constructed based on the prototype apartment building, and nonlinear static analysis (push-over analysis) was performed. Based on the finite element (FE) analysis model, the parametric study was conducted to investigate the effects of various design parameters on the strength and crack width of the exterior walls. As the parameters, the vertical reinforcement ratio and horizontal reinforcement ratio of the wall, as well as the uniformly distributed longitudinal reinforcement ratio and shear reinforcement ratio of the connection beam, were addressed. The analysis results showed that the strength and deformation capacity of the prototype exterior walls were limited by the failure of the connection beam prior to the flexural yielding of the walls. Thus, the increase of wall reinforcement limitedly affected the failure modes, peak strengths, and crack damages. On the other hand, when the reinforcement ratio of the connection beams was increased, the peak strength was increased due to the increase in the load-carrying capacity of the connection beams. Further, the crack damage index decreased as the reinforcement ratio of the connection beam increased. In particular, it was more effective to increase the uniformly distributed longitudinal reinforcement ratio in the connection beams to decrease the crack damage of the coupling beams, regardless of the type of the prototype exterior walls.
        4,200원
        13.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Laurencia is a red algal genus that was described by J.V. Lamouroux in 1813. The main characteristics of this genus have been known as the presence of four pericentral cells in an axial segment, secondary pit connections between adjacent epidermal cells, and the presence of corps en cerise in both epidermal and trichoblast cells. Additionally, the tetrasporangia are arranged in a parallel manner, and male branches feature terminal cup-shaped spermatangial pits. Currently, sixteen Korean Laurencia species have been reported based on their morphological characteristics. In this study, Laurencia decussata and L. pacifica have been added as new records to the Korean algal flora based on a combination of morphological observations and molecular analyses of rbcL sequences. Laurencia decussata has expanded from Australia and New Zealand to Korea, while the distribution of L. pacifica has expanded from USA and Mexico to Korea.
        4,200원
        14.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        가상의 공간에서 함께 즐기는 콘텐츠에 대해 관심이 늘어나고 있다. 더불어 가상공간에서 나만의 아바타도 꾸미고 게임 콘텐츠 역시 즐기고 있다. 이러한 가상의 공간을 메타버스라고 하며 대표적인 플랫폼으로는 제 페토와 로블록스가 있다. 메타버스 플랫폼은 플랫폼의 취지에 맞게 유저가 직접 제작하기 편리한 컨텐츠 제 작 도구를 지원한다. 그러나 일반 유저가 제작한 콘텐츠는 메타버스에서 활동하고 있는 다양한 유저의 관심 과 흥미를 지속적으로 유발하기에는 부족한 부분이 있어 꾸준한 흥행이 어렵다. 본 논문은 기존 게임 엔진을 활용해서 콘텐츠를 제작하는 콘텐츠 개발자로서 메타버스 플랫폼이 제공하는 제작 도구의 효용성을 검증하 고자 게임 엔진의 선택 기준을 참고하여 인터페이스, 개발 언어, 개발 공정의 기준으로 대표하는 플랫폼의 제작 도구를 비교하였다.
        4,000원
        15.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : Safety Evaluation of Wind Loads of Renewable Energy and Photovoltaic Power Structures. METHODS : Structural safety evaluation was conducted on the wind load of 3kW Photovoltaic Power Structures using ABAQUS. Wind speed was reviewed for 36m/s and 60m/s. Effective Mass and Mass Contribution of Photovoltaic Power Structures was utilized up to 90%. 7 steps were set and applied to structural analysis. RESULTS : As a result of the structural analysis, it was confirmed that the long-term blowing load was affected rather than the size of the wind load. Weak areas were identified at the point of the horizontal beam rather than the modules of the Photovoltaic Power Structures. In particular, it was confirmed that stress exceeding the allowable stress was generated at the junction. In order to secure the safety of Photovoltaic Power Structures, it is judged that reinforcement of the branch is necessary. CONCLUSIONS : The safety of Photovoltaic Power Structures structures for wind load is influenced by persistence rather than the size of the wind load. Therefore, in order to prevent this, it is judged that reinforcement of the branch is necessary.
        4,000원
        16.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목적: 본 연구는 남성 척수손상 환자들을 대상으로 사회연결망 분석을 활용하여 작업연결망의 구조를 분석하는 데 목적이 있다. 연구방법: 연구대상은 남성 척수손상 환자 12명이다. 대상자들의 작업연결망 구조는 사회연결망 분석을 활용하였 으며, 연결망 분포에 대한 지표와 중심성에 대한 지표로 구분하여 분석하였다. 연결망 분포에 대한 지표는 밀도, 평균 연결정도, 평균 거리, 포괄성, 고립노드를 분석하였다. 중심성에 대한 지표는 연결정도 중심성과 매개 중심성을 분석하였다. 일상생활 활동의 항목은 지역사회 건강조사 활동항목을 활용하여 조사하였으며, 활동에 대한 강도는 만족도로 설정하였고, 10점 척도로 조사하여 적용하였다. 결과: 연결망 특성에서 밀도는 60%, 평균 연결정도는 8.40, 평균 거리 1.40, 포괄성 100%, 고립노드 0으로 나타났다. 중심성 분석 결과 내향 연결정도 중심성과 외향 연결정도 중심성 모두 참여활동, 개인건강관리, 교제활동의 순으로 높게 나타났다. 매개 중심성 분석 결과 개인건강관리, 교제활동, 여가활동 순으로 높게 나타났다. 결론: 본 연구에서는 사회연결망 분석을 활용하여 척수손상 환자들의 작업수행에 대한 구조와 그 특성을 파악하였다. 본 연구에서 분석한 결과는 척수손상 환자들의 일상 속에서 만족감을 지니며 수행하고 있는 작업수행의 구조를 의미한다. 이에, 본 연구결과는 척수손상 환자들이 자신의 일상을 더욱 의미 있게 구성하고, 작업수행에 적극적으로 참여할 수 있는 근거로서 활용할 수 있는 중요한 의미와 가치를 지니며, 임상적으로 의미를 지닌다. 이에, 본 연구 결과는 척수손상 환자들의 재활과정에서 작업수행에 대한 참여를 확대하고, 영역별 확장을 유도할 수 있는 기초자료로서 활용할 수 있을 것으로 판단된다.
        4,000원
        17.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The membrane structure should maintain the membrane materials in tension for structural stability guaranty. The anchoring part in the membrane structure is an important part. It has the function to introduce tension into membrane materials and function to transmit stress which membrane materials receives to boundary structure such as steel frames. In this paper, it grasps anchoring system of the anchoring part in the membrane structure concerning the fracturing characteristic condition of membrane structure, and the influence which is caused to yield it designates the stress state when breaking the membrane structure which includes the anchoring part and that stress transition mechanism is elucidated as purpose. This paper follows to previous paper, does 1 axial tensile test concerning the bolting part specimen, grasp of fracturing progress of the bolting part and the edge rope and hardness of the rubber, does the appraisal in addition with the difference of bolt tightening torque. As a result, the influence which the bolt anchoring exerts on the fracturing characteristics of the membrane material in the membrane structure anchoring part is examined.
        4,000원
        18.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the seismic response characteristics of the three analysis model with or without TMD were investigated to find out the effective dome shape. The three analysis models are rib type, lattice type and geodesic type dome structure composed of space frame. The maximum vertical and horizontal displacements were evaluated at 1/4 point of the span by applying the resonance harmonic load and historical earthquake loads (El Centro, Kobe, Northridge earthquakes). The study of the effective TMD installation position for the dome structure shows that seismic response control was effective when eight TMDs were installed in all types of analysis model. The investigation of the efficiency of TMD according to dome shape presents that lattice dome and geodesic dome show excellent control performance, while rib dome shows different control performance depending on the historical seismic loads. Therefore, lattice and geodesic types are desirable for seismic response reduction using TMD compared to rib type.
        4,000원
        19.
        2023.11 구독 인증기관·개인회원 무료
        Kori unit 1 and Wolsong unit 1 were permanently shut down in 2017 and 2019, respectively. Both plants were decided to demolish the building without reuse. Large structures must be demolished after removing systems and components in the building, and in the case of large structures, thorough planning is required because of the large scale of work. Therefore, in this study, important considerations in the phase of the demolition plan of large structures when decommissioning were analyzed. The demolition of large structures at nuclear facilities is major one phase of work within a broader decommissioning plan. Furthermore, the actual demolition of the structure (i.e., physical process) represents the last step in a process that begins with extensive planning and analysis. The National Demolition Association (NDA) has provided checklist items that should be considered before the start of a commercial demolition project and/or in the bid process. Important Considerations in the Phase of the demolition plan of large structures when decommissioning of nuclear facilities are Site knowledge and programs, Engineering survey/demolition plan, Hazardous and radioactive materials, Open air demolition, Financial and project management, Permits, Code adherence, and Special programs, Disposal pathway, Final site condition. The results of this study can be used as a basis for the Planning large structures demolition of the Kori unit 1 and Wolsong unit 1.
        20.
        2023.11 구독 인증기관·개인회원 무료
        The process of carbonization followed by a high-temperature halogenation removal of radionuclides is a promising approach to convert low-radioactivity spent ion-exchange (IE) resins into freereleasable non-radioactive waste. The first step of this process is to convert spent ion-exchange resins into the carbon granules that are stable under high-temperature and corrosive-gas flowing conditions. This study investigated the kinetics of carbonization of cation exchange resin (CER) and the changes in structures during the course of carbonization to 1,273 K. Both of model-free and modelfitted kinetic analysis of mixed reactions occurring during the course of carbonization were first conducted based on the non-isothermal TGAs and TGA-FTIR analysis of CER to 1,272 K. The structural changes during the course of carbonization were investigated using the high-resolution FTIR and C-13 NMR of CER samples pyrolyzed to the peak temperature of each reaction steps established by the kinetic analysis. Four individual reaction steps were identified during the course of carbonization to 1,273 K. The first and the third steps were identified as the dehydration and the dissociation of the functional group of —SO3-H+ into SO2 and H2O, respectively. The second and the fourth steps were identified as the cleavage of styrene divinyl benzene copolymer and carbonization of pyrolysis product after the cleavage, respectively. The temperature and time positions of the peaks in the DTG plot are nearly identical to those of the peaks of the Gram Schmidt intensity of FTIR. The structural changes in carbonization identified by high-resolution FTIR and DTG are in agreement with those by C-13 NMR. The results of a detailed examination of the structural changes according to NMR and FTIR were in agreement with the pyrolysis gas evolution characteristics as examined by TGA-FTIR.
        1 2 3 4 5