검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 171

        41.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this analysis, the analytical model was verified through the normal mode analysis of the piston for the 2.9 liter IDI (indirect injection) engine. Heat transfer analysis was carried out by selecting two cases of applied temperature using the validated model. The first case was a condition of 350℃ on the piston upper surface and 100℃ on the piston body and inner wall. In the second case, the conditions were set to give a temperature of 400℃ on the upper surface of the piston and 100℃ on the piston body and the inner wall. In addition, the temperature distribution due to heat transfer was obtained for the pistons with boundary conditions of two cases, and then the thermal stress distribution due to thermal expansion was obtained using the input. Using this analysis result, the thermal stress caused by thermal expansion due to the thermal conduction of the piston is examined and used as the basic data for design.
        4,000원
        42.
        2020.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Engine components subjected to cyclic thermal and mechanical loads may experience low-cycle or high-cycle fatigue failures. In particular, both of these failures can easily occur in aluminum cylinder heads, which are exposed to high temperatures and combustion pressures. Predicting the fatigue characteristics of the cylinder head are very important in the design stage of engine development. In this study, a finite element analysis was performed to predict the low-cycle thermal fatigue around exhaust ports of the cylinder head. Temperature distributions are obtained through the heat transfer analysis considering thermal cyclic test. The analysis result involves large plastic deformations, indicating compressive stresses at high temperatures and subsequently turn into tensile stresses at cold conditions. And the results showed that the critical regions such as exhaust port with large plastic strains coincided well with crack locations from thermal cyclic test. Next, design changes were made to the critical areas of the exhaust ports, and the results showed that the durability was improved by about 60% over the initial model and there were no problems in the thermal fatigue test.
        4,000원
        51.
        2019.04 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        As a case study on aspect ratio behavior, Kaolin, zeolite, TiO2, pozzolan and diatomaceous earth minerals are investigated using wet milling with 0.3 pai media. The grinding process using small media of 0.3 pai is suitable for current work processing applications. Primary particles with average particle size distribution D50, ~6 μm are shifted to submicron size, D50 ~0.6 μm, after grinding. Grinding of particles is characterized by various size parameters such as sphericity as geometric shape, equivalent diameter, and average particle size distribution. Herein, we systematically provide an overview of factors affecting the primary particle size reduction. Energy consumption for grinding is determined using classical grinding laws, including Rittinger's and Kick's laws. Submicron size is obtained at maximum frictional shear stress. Alterations in properties of wettability, heat resistance, thermal conductivity, and adhesion increase with increasing particle surface area. In the comparison of the aspect ratio of the submicron powder, the air heat conductivity and the total heat release amount increase 68 % and 2 times, respectively.
        4,000원
        52.
        2019.03 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        현재 고려되고 있는 단층 심지층처분장 개념은 부지 소요면적이 지나치게 크기 때문에, 처분밀도를 향상시키기 위한 다층 심지층처분장 개념이 제안되고 있다. 심부암반에 건설된 다층 심지층처분장 주위에 형성된 암반손상대가 심지층처분장의 온도 분포에 미치는 영향이 분석되었다. 다층 심지층처분장의 열해석에는 완충재, 뒤채움재 및 암반에서 일어나는 재포화 현상을 고려한 열-수리 모델이 사용되었다. 암반손상대의 존재는 심지층처분장의 온도 분포에 큰 영향을 미치는 것으로 나 타났으며, 손상대의 크기와 열전도도 저하 정도에 따라 복층 및 삼층 심지층처분장의 최고첨두온도를 각각 최대 7℃와 12℃ 까지 증가시킬 수 있다. 다층 심지층처분장의 첨두온도에 영향을 크게 미치는 인자는 암반손상대에서의 열전도도 저하이며, 처분공 주위에 형성된 암반손상대가 처분터널 주변에 형성된 암반손상대보다 첨두온도에 더 큰 영향을 미친다.
        5,500원
        53.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        of the marketed multi-later insulating curtain was carried out. Experiments is conducted by fabricating a test apparatus for investigating the heat flux characteristics. The multi-later insulating curtain used for the experiment was compared using the P, N, S, U and T company, which are commercially available, and the heat flux due to temperature difference between the experimental apparatus and the outside was compared and analyzed. When the internal temperature of the experimental result is the maximum temperature 60℃, the heat flux of multi-later insulating curtain is T Co.(73.1W/m2) > S Co.(119.5W/m2) > U Co.(155W/m2) > N Co.(163.1 W/m2) > P Co.(177.7W/m2). The heat flux means the quantity of heat passing through the unit time per unit area, and the higher the numerical value, the higher the quantity of heat passing through the multi-layer insulating curtain. This can be determined that high heat fluxes produce low heat resistance. Further, it has been found that the weight of the insulating curtain is largely unrelated to the heat insulating property, and the heat insulating curtain having a thickness containing a high internal air layer is excellent in the heat insulating property. In the future when manufacturing a heat insulating curtain, It is judged that it is desirable to manufacture a combination of heat insulating materials that contain a high internal air layer content and that can maintain the air layer even for long-term use while minimizing the volume.
        4,000원
        56.
        2018.06 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Bird screen meshes are installed at the air inlet and outlet ducts of spent fuel storage casks to inhibit the intrusion of debris from the external environment. The presence of these screens introduces an additional resistance to air flow through the ducts. In this study, a porous media model was developed to simplify the bird screen meshes. CFD analyses were used to derive and verify the flow resistance factors for the porous media model. Thermal analyses were carried out for concrete storage cask using the porous media model. Thermal tests were performed for concrete casks with bird screen meshes. The measured temperatures were compared with the analysis results for the porous model. The analysis results agreed well with the test results. The analysis temperatures were slightly higher than the test temperatures. Therefore, the reliability and conservatism of the analysis results for the porous model have been verified.
        4,000원
        57.
        2018.05 구독 인증기관·개인회원 무료
        As carbon material is being developed the versatile one with merits of metal, non-metal, ceramic and plastic etc., it owes to the characters of light weight and strength comparing with other metal materials. Based on these characters it is applied to vehicle lightening and aerospace industry. Furthermore thermal function utilization, removal of environmental pollution material, prevention of water pollution and the area of medicine science combining into drug as well. Therefore in this study we analyze technology paradigm home and abroad for carbon material on the basis of its relative patents and consider the establishment of technology strategy for its business commercialization
        58.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        쓰레기 소각장이나 산업체의 폐열을 농업에 활용한 사례는 몇몇 있었다. 그러나 온배수를 농업에 활용한 사례는 전무하였으며, 치어, 종패 등을 양식하는 수산업이 대부분이었다. 본 연구에서는 화력발전소의 온배수(폐열)를 열원으로 이용하는 120 RT 규모의 냉난방시스템을 제주특별자치도 서귀포시 안덕면 소재의 5,280m2 아열대 작물(망고) 재배 온실에 설치, 10월에서 다음해 2월까지 약 5개월 동안 난방을 실시하여 난방에너지 비용 절감 효과 등 분석하였다. 난방에너지 비용 절감효과는 면세경유에 대하여 87%이였으며, 또한 발전소의 온배수를 에너지원으로 재활용함으로 서 62%의 이산화탄소 배출 저감 효과를 얻었다. 본 연구를 계기로 2015년에 해수가 수열에너지 분야로 재생에너지에 포함되었다. 해수의 표층의 열을 히트펌프를 사용하여 변환시켜 얻은 에너지라는 수열에너지 분야의 기준과 범위를 볼 때, 이는 온배수가 재생에너지에 포함되었다고 말해도 과언이 아닐 것으로 사료된다. 그 이유는 온배수도 해수임에도 불구하고 온도가 일반 해수 보다 7~8oC 높아, 일반 해수를 히트펌프의 열원으로 이용하는 것보다 온배수를 열원으로 이용했을 때 히트펌프의 성능이 높기 때문이다. 또한 같은 해 농식품부의 폐열 재이용 시설 지원 사업이 발표되어, 발전소 온배수뿐만 아니라 산업체와 소각장의 폐열을 농업에 활용하면 지원을 받을 수 있게 되었다. 이 사업에 의하여 2015년 당진시, 하동군, 제주시, 곡성군이 선정되었으며, 2016년 태안군, 서귀포시 등이 선정되어, 2016년 말 곡성군과 제주시가 공사를 완료, 농업에 폐열을 활용하고 있으며(제주시는 발전소, 곡성군은 산업체 폐열을 이용하고 있음), 기타 지역은 추진 중이다.
        4,000원
        1 2 3 4 5