검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 205

        81.
        2014.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Microalgae is known as one alternative energy source of the fossil fuel with the small size of 5 ~ 50 µm and negative charge. Currently, the cost of microalgae recovery process take a large part, about 20 - 30% of total operating cost. Thus, the microalgae recovery method with low cost is needed. In this study, the optimum current for Scenedesmus dimorphus recovery process using electrocoagulation techniques was investigated. Under the electrical current, Al metal in anode electrode is oxidized to oxidation state of Al3+. In the cathode electrode, the water electrolysis generated OH- which combine with Al3+ to produce Al(OH)3. This hydroxide acts as a coagulant to harvest microalgae.Before applying in 1.5 L capacity electrocoagulation reactor, Scenedesmus dimorphus was cultured in 20 L cylindrical reactor to concentration of 1 OD.The microalgae recovery efficiency of electrocoagulation reactor was evaluated under different current conditions from 0.1 ~ 0.3 A. The results show that, the fastest and highest recovery efficiency were achieved at the current or 0.3 A, which the highest energy efficiency was achieved at 0.15 A.
        4,000원
        82.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The predictive capacity of wastewater treatment facility in the industrial park was estimated by the traditional method and on-the-spot survey such as certification of wastewater report and the invoices of water supply and ground water supply. The ratios of a converted wastewater to supplied industrial water between traditional method and on-the-spot survey in the estimation methods were different. By using traditional method, the business type of clothes, accessary and fur production had 77.18 % of waste ratio of wastewater and 10.72 m3/day·1000 m2 unit mass of wastewater as the highest among 9 business types. With the respect to the on-the-spot survey, food manufacturing business type had 75 % of waste ratio of wastewater and 8.35 m3/day·1000 m2 unit mass of wastewater as the highest values. The amount of wastewater from on-the-spot survey method was 541 m3/day less than one from traditional method.
        4,000원
        83.
        2014.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Study on effluent organic matter (EfOM) characteristic and removal efficiency is required, because EfOM is important in regard to the stability of effluents reuse, quality issues of artificial recharge and water conservation of aqueous system. UV technology is widely used in wastewater treatment. Many reports have been conducted on microbial disinfection and micro pollutant reduction with UV treatment. However, the study on EfOM with UV has limited because low/medium pressure UV lamp is not sufficient to affect refractory organics. The high intensity of pulsed UV would mineralize EfOM itself as well as change the characteristics of EfOM. Chlorine demand and DBPs formation is affected on the changed amounts and properties of EfOM. The objective of this study is to investigate the effect on EfOM, chlorine residual, and chlorinated DBPs formation with low pressure and pulsed UV treatment. The removal of organic matter through low pressure UV treatment is insignificant effect. Pulsed UV treatment effectively removes/transforms EfOM. As a result, the chlorine consumption is changed and chlorine DBPs formation is decreased. However, excessive UV treatment caused problems of increasing chlorine consumption and generating unknown by-products.
        4,300원
        84.
        2014.02 구독 인증기관 무료, 개인회원 유료
        Most small laundry factory has been operated without not only environmental expertise but also technical process. The objective of this study is to get the optimal coagulation dosage for satisfaction of discharge permission standard of laundry wastewater treatment plant(WTP) effluents by jar test.The coagulants are alum and sodium hydroxide(NaOH), coagulants aids is polymer. Also, the best coagulation reaction was shown in the following conditions ; Alum 4.13g/L, NaOH 1.03g/L, Polymer 0.27g/L on average. The optimal coagulation dosage could be reduced costs to 4.43 million won a year. It was considered that operating a small WTP was an important technical data in same industry.
        4,000원
        85.
        2014.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        주류를 제외한 과일 및 탄산음료 등을 제조하는 비알코올성 음료품 제조시설에서 발생되는 폐수는 높은 농도의유기물과 낮은 농도의 질소, 인 등을 함유한다. 이러한 폐수의 처리 시설은 주로 호기성 공정과 약품응집 공정으로 구성하고 후단에 사여과지 또는 활성탄 공정을 추가하기도 한다. 하지만 이러한 방식은 긴 체류시간과 침전지 설치로 인해 많은 부지를 필요로 하는 문제가 있다. 본 연구에서는 부지소요 문제와 슬러지 유출로 인한 수질저하 문제를 해결하고자 W식품공장 폐수처리장 인근에 MBR pilot plant를 설치하고 장기간 운영을 통해 데이터를 확보하고 처리 효율을 평가하였다. 약 3개월간음료수 제조공정 폐수를 평막을 적용한 MBR pilot plant로 운전조건을 변화하며 처리한 결과, 처리유량 20 m3/day, HRT 29hr, 4Q 반송조건까지는 유기물 제거율 97% 이상으로 안정적인 처리가 가능했다. 하지만 그 이상의 운전조건에서는 생물반응조의 오염물질 제거율이 감소하였고 TMP가 급격히 증가하는 모습을 보였다.
        4,000원
        86.
        2013.02 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to get basic data for the application of coagulants for treating an industrial wastewater containing NBD COD. The NBD COD concentration of the target wastewater was calculated to be 61 mg/L, which was about 72% of the first stage treated water, and this shows that there must be advanced wastewater treatment process. When Alum(8%) was injected in raw the water, 150ppm was the best dosage and 41% CODmn removal efficiency was obtained. When Alum(8%) was injected in the discharge water, 150ppm was the best dosage, and 19% CODmn removal efficiency was obtained. When powdered activated carbon was injected, 40ppm was the best dosage, 26% CODmn removal efficiency was obtained. The method of injecting Alum(8%) in the discharge water was suitable, when the effluent exceeds the water quality standard by 20%, and the method of injecting the powdered activated carbon was suitable, when the effluent exceeds the water quality standard by 20~40%.
        4,000원
        87.
        2013.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        MBR 기술은 지난 20여 년 동안 처리성능과 효율성 그리고 비용절감 측면에서 빠른 속도로 발전하고 있다. 또한 안정적인 하수처리와 하수재이용관점에서 핵심기술로 널리 인식되고 있다. 본고에서는 MBR 기술의 개발과 상업적 응용에 관한 발전과정을 재조명하고 세계 시장의 전망을 제시하고자 한다. 주요 적용기술에 대해 다음 5가지 측면에서 검토하여 제시하였는데 1) MBR 기술의 진화, 2) MRBs의 상업용 기술, 3) 대용량 MBR 플랜트 설치 사례, 4) MBR 시장의 성장, 5) 기술의 발전방향 순으로 제시하였다. 마지막으로 MBRs에 대한 경제적, 환경적, 그리고 기술적 측면에서 향후 발전방향을 1) 초기투자비, 2) 처리 수질, 3) 분리막 소재/모듈, 4) MBR 장비와 공정, 5) 운영비용, 향후 6) 혐기성 MBRs 공정과 같은 차세대 기술 분야로 나누어 제시하였다.
        5,700원
        89.
        2012.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 생활오수, 산업폐수, 축산폐수 등에서 발생하는 질산성화합물 및 난분해성 화합물을 효과적으로 처리하기 위해 막분리법과 다공 전극형 전기분해법을 조합한 하 폐수의 고도처리 기술을 제안하였고 제안 시스템의 효율성을 검토하였다. 제안하는 시스템은 활성슬러지 공정, 막분리 공정, 다공 전극형 전기분해공정의 3단계로 구성하였다. 본 연구에서 구성되는 막분리 공정은 부유물질을 제거해줌으로써 전기분해공정의 부하를 최소화할 수 있는 역할을 담당할 수 있게 하여 시스템을 안정하게 운전할 수 있도록 하였다. 전기분해 하이브리드 공정에 있어서는 다공성 전극으로 구성함으로써 비표면적의 확대로 인한 전극의 효율성을 높였다. 아울러 외부전압을 인가함에 따라 처리제의 공급 없이 장치에 유입된 물을 분해시킴으로써 산화 환원 반응을 유도하였다. 즉 중간체로서 수소 자유전자 라디칼과 산소원자 라디칼이 발생되어 난분해성 유기물을 산화 분해하는 역할을 담당하도록 하였다. 이는 전극 내에서 발생하는 중간체를 폐용질의 분해에 사용하기 때문에 친환경적 처리공법이었다. 실험결과들은 제안공정이 활성슬러지공법에 비하여 우수한 공정임을 보여 주었다. SS제거율은 제안공정, 막분리공정, 활성슬러지 단독공정에서 각각 약 100%, 약 100%, 약 90%였고 COD 제거효율은 제안공정 약 92%, 막분리공정 약 84%, 활성슬러지 단독공정 약 75%였으며 T-N의 제거효율은 제안공정 약 88%, 막분리공정 약 67% 활성슬러지 단독공정 약 58%였다. 이결과는 SS의 제거에 있어서 막분리 하이브리드 공정만으로도 부유물질이 충분히 제거됨을 나타내고 있었다. COD의 제거에 있어서 막분리 하이브리드 공정은 SS분의 제거를 통한 COD와 SS이외의 유기물질이 소량제거 되었음을 보였고 전기분해 하이브리드 공정에 있어서는 유기물질의 산화반응을 통한 분해로 높은 제거효율을 보였다. T-N의 제거에 있어서는 막분리 하이브리드 공정은 SS분에 포함된 부분과 소량의 유기물에 포함된 부분이 제거되고 있는 반면 전기분해 공정에 있어서는 유기물질의 산화분해반응으로 인한 높은 제거효율을 나타내고 있었다.
        4,000원
        90.
        2012.02 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to evaluate for performance of biochipfiltration phosphorus treatment process developed by ANT21 and to enhance phosphorus water quality standards to meet the optimum operation conditions of phosphorus treatment process are presented. Alum, FeCl3 as the coagulant used, each with a Jar-Test influent water quality and remaval efficiency of phosphorus treatment process when compared to water quality and removal efficiency of T-P are not a big difference, Alum in the removal efficiency and water quality was the most stable and high coagulant in the case of the removal of CODmn, SS, TN. Alum and Polymer processing efficiency when using the water quality was good and treatment water quality is CODmn 19 mg/L, SS 5 mg/L, TN 26 mg/L, T-P 0.135 mg/L less than water quality standards. If Alum is applied to the field, Alum injection amount per m3 influent unit is 24 g. During the field testing operation period, the influent has average COD mn 27 mg/L, SS 10 mg/L, T-N 22 mg/L, T-P 0.910 mg/L, and the final effluent has average CODmn 22 mg/L, SS 4 mg/L, T-N 20 mg/L, T-P 0.166 mg/L respectively. Average removal efficiency of each water quality item was CODmn 21%, SS 65%, T-N 8%, TP 82% and phosphorus treatment process is effective for the removal of SS and T-P but there is a limit to the removal of CODmn and T-N.
        4,600원
        91.
        2011.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        1980년대 이후 국내 하 폐수 처리시설에 대한 지속적인 투자로 하수도 보급률이 90%에 이를 만큼 비약적으로 확충되었다. 21세기 들어 물 부족에 대비한 대체수자원 확보, 기후변화 등 지구환경문제에 대비한 에너지 절감 및 생산, 하천 호소의 지속적인 수질개선 요구 등 사회적 환경적 영향 요소를 감안할 때 더욱 고도화된 선진 하 폐수 처리기술이 필수적이다. 신개념 처리기술은 수질유해물질 및 독성관리기술 등 초고도 처리기술, 맞춤형 재이용기술, 에너지 절감 회수 활용 기술을 유기적으로 조합 연계하는 기술이다. 이러한 선진 처리기술은 국내 수질환경개선은 물론 개도국을 중심으로 급성장세를 보이는 국제 환경시장에서의 경쟁력 확보의 토대가 될 것이므로 글로벌 탑 수준을 지향하는 하 폐수 고도처리 기술개발 사업에서는 상기 기술 분야를 중점 개발하고자 한다. 본 사업단은 방류수 고품질화. 재이용 기술 분야, 에너지자립 분야, 통합관리 분야로 구분, 향후 1단계 5개년(2011-2015) 사업을 본격 추진할 예정이다.
        4,500원
        93.
        2009.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A mathematical model was written for simulating the removal of phenol from wastewater in enzyme-loaded membrane reactor (EMR). The numerical simulation program was developed so as to predict the degradation of phenol through an EMR. Numerical model proves to be effective in searching for optimal operating conditions and creating an optimal microenvironment for the biocatalyst in order to optimize productivity. In this study, several dimensionless parameters such as Thiele Modulus (Φ2, dimensionless Michaelis-Menten constant (ξ), Peclet number (Pe) were introduced to simplify their effects on system efficiency. In particular, the study of phenol conversion at different feed compositions shows that low phenol concentrations and high Thiele Modulus values lead to higher reactant degradation.
        4,200원
        94.
        2008.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 영산강유역 농공폐수처리장 방류수중의 유기오염물질 분포를 관찰하였다. 시료채취 지점은 영산강 유역에 존재하는 4지점의 농공단지 폐수처리장을 선정하였다. 본 연구에서 GC-Ion trap MS로 300종의 일반적인 화학물질을 ppt수준에서 검출할 수 있는 방법을 이용하여 분석하였다. 농공폐수처리방류수에서 검출된 주요 유기오염물질은 농약류, CH구조의 방향족, CHO구조의 프탈레이트류, 그리고 CHO(N) 구조의 아로메틱 아민류였다. 또한 diethylphthalate를 포함한 17종의 내분비계장애물질이 검출되었다. XTT assay를 이용한 세포독성 결과는 TV로 나타냈으며, 그들의 세포독성은 A지점에서 27.2, D지점에서 24.4로 가장 높게 나타났다. 한편 화학적 분석 결과와 생물학적 독성도와는 일치하지 않는 것으로 나타났다.
        4,000원
        95.
        2008.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        전도성 활성탄소와 폴리비닐리덴플로라이드(PVDF)를 이용하여 제조된 탄소막을 이용하여 폐수의 Total dissolved Solid (TDS)를 제거할 수 있는 탄소막 시스템을 제조하였다. 100 ppm의 NaCl, Na2SO4, MgCl2, MgSO4수용액을 이용하여 탄소막의 기본 특성을 알아보았으며, (주)경인양행의 실제폐수인 염료폐수로부터 TDS를 제거하는 실험을 위하여 가로 × 세로가 각각 20cm인 탄소막 240장으로 구성된 Pilot 규모의 탄소막 시스템을 구성하였다. 원폐수를 초순수로 적절히 희석하여 제조된 6가지의 TDS (941, 2050, 2810, 3830, 4960, 6030 ppm)를 지닌 실제폐수를 이용하여 제조된 Pilot규모의 탄소막 시스템의 TDS 제거성능을 알아보았으며, 여러 운전조건에 따른 탄소막 시스템의 분리특성을 알아보았다.
        4,000원
        96.
        2008.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        염색폐수처리를 위하여 피페라진, 메타페닐렌디아미, 트리메소일 클로라이드를 이용하여 계면중합법으로 폴리아마이드계 나노분리막과 폴리아마이드계 역삼투막을 제조하였으며, 이들을 오스모닉스사로부터 구입한 역삼투막의 투과특성과 비교하였다. 이들의 기본 분리투과특성 조사를 위하여 PEG 600, Na2SO4, NaCl 수용액을 이용하였으며, 제조된 분리막들은 전형적인 나노복합막과 저압용 역삼투막의 특성을 나타내었다. 제조된 이들 분리막들을 이용하여 국내 염료 제조업체인 (주)경인양행으로부터 공급된 실제 염색폐수를 처리하였으며, 이때 이들의 분리투과특성을 살펴보았다. 또한 분리막을 이용한 폐수처리 시 발생되는 분리막 오염을 제거하기 위하여 일정시간마다 CIP를 실시하였다. 이때 3종류의 서로 다른 화학세정제를 사용하였으며, 이들의 세척성능을 살펴보았다.
        4,000원
        97.
        2007.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Based on the experiment results of laboratory scale modified anoxic-oxic process for leachate treatment, biological nitrogen removal program was verified in terms of SS, COD, and TN concentration. These measured water qualities concentration could be predicted by biological nitrogen removal program with R2 of 0.994, 0.987, 0.990, respectively. No error was occurred between water qualities concentration and quite wide range of water qualities concentration (i.e., 50-4200 mg/L) during the modelling. Each unit and final effluent of simulated concentration was kept good relationship with that of measured concentration therefore this biological nitrogen removal program for sewage or wastewater treatment plants has good reliance.
        4,000원
        98.
        2007.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The application of membrane bioreactors for the depuration of wastewater coming from the washing of mineral oil storage tanks is described. Microfiltration hollow-fibre membranes were used in the submerged configuration. Filtration tests were carried out with a biomass concentration of about 15 g/L in order to assess the critical flux of the hollow fibre membrane used. Then particular care was taken in carrying out the performance runs in the sub-critical flux region. The reactor performance was very high, with removal efficiencies ranging between 93% and 97% also when the concentration of hydrocarbon was very high. Some kinetic parameters for the COD and the hydrocarbon removal were estimated.
        4,000원
        99.
        2006.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        우유 또는 주스 종이용기를 재활용하여 화장지를 생산하고 있는 제지회사에서 배출되는 제지폐수를 대상으로 주기적 질소 역세척이 가능한 세라믹 정밀여과 시스템을 운전하였다. 제지폐수 재활용을 위해 본 연구에서 7개의 채널이 있는 2 종류의 알루미나 분리막이 사용되었다. 질소 역세척 시간을 40초, 막간압력차 1.0kgf/cm2, 역세척 압력 5.0kgf/cm2로 고정하였을 때 0.4mum의 평균기공 크기를 갖고 있는 HC04 알루미나 분리막의 최적 여과시간 간격은 4분으로 1.0mum의 평균기공인 HV10 분리막의 16분보다 짧았다. 여과시간 간격과 역세척 시간을 고정한 상태에서 막간압력차(TMP)의 영향을 살펴본 결과, 높은 TMP 조건에서는 쉽게 막표면에 케이크가 형성되고 막 내부 구조에도 막오염이 발생하기 때문에 낮은 TMP 조건이 막오염 제어에 유리한 것을 알 수 있었다. 그러나 TMP는 폐수처리 여과 시스템에서 구동력이기 때문에, 가장 높은 TMP 조건에서 가장 많은 총여과부피를 얻을 수 있었다. 한편, 다채널 세라믹 분리막을 사용한 정밀여과시스템에서 얻은 투과수는 탁도가 낮기 때문에 제지공정에서 재활용 될 수 있다.
        4,000원
        100.
        2005.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 도시 하수처리를 위한 막결합형 A2O공정에 관해 실제적인 정보를 얻고자 하는 것이다. 공경 0.25;μm의 평판형 정밀여과막을 공기가 주입되는 호기조에 침지시켜 처리수는 저압으로 여과된다. 인공폐수를 대상으로 최적의 처리수질과 장기운전의 안정성 확보를 위한 내부반송율과 MLSS 농도 등의 최적 운전인자를 산정하고자 하였다. 내부반송은 각각 호기조에서 무산조로 반송한 것을 type 1, 무산조에서 혐기조로 반송한 것을 type 2라고 규정지었다. 플럭스는 15 LMH, type 1을 2Q로 고정하고 실험하였을 때 최적의 운전 조건은 MLSS 농도는 11,000 mg/L, type 2가 IQ로 나타났다. 이때, BOD CODcr, T-N, T-P의 제거율이 각각 97.3%,;94.2%,;64.0%,;63.0%로 타 내부반송율보다 효과적이었다.
        4,000원