This study attempts to investigate the impact of pollution by VOCs at schools located around Shihwa national industrial complex. Schools around the Shihwa national industrial complex were divided into two categories based on location, with five schools located near the industrial complex and five schools located near housing development. Samples of the indoor air and the outdoor air were collected from each classified school and analyzed to evaluate the impact of the industrial complex on each school through a comparison and to find the correlation between them. In combination with this, this study attempted to conduct comparative evaluations of the schools in which there might be relatively higher indoor air pollution since new construction and extension or remodelling had recently been carried out with other schools. The samples collected from 10 places in total were analyzed, using GC/MS. TVOCs, and individual component of VOCs, were detected in the schools near shihwa national industrial complex at higher levels than in the schools nearby housing development. TVOCs were detected at the schools in the industrial complex st levels of 166.5 μg/m3, that is, about 1.5 times higher than the level detected at the schools outside the industrial complex. TVOCs were found in the indoor air of the schools that had been extended or remodelled less than 3 years ago at levels of 188.8 μg/m3, while in schools where more than 3 years had passed since extention or remodelling they were found at levels of 97.5 μg/m3, meaning they were about 1.9 times higher in schools in the first 3 years.