논문 상세보기

고온・고압 노내조사시험설비의 부동태 처리 KCI 등재

Passivation for High Temperature and Pressure Irradiation Test Loop

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/169118
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
한국기계기술학회지 (Journal of the Korean Society of Mechanical Technology)
한국기계기술학회 (Korean Society of Mechanical Technology)
초록

Fuel test loop is an irradiation test facility which can conduct the irradiation tests of nuclear fuels and materials at HANARO. The FTL simulates the operating conditions of commercial nuclear power plants such as their pressure, temperature, flow and water chemistry to conduct the irradiation and thermo-hydraulic tests. The passivation of the fuel test loop was performed for the main cooling system in the commissioning stage with satisfaction of the operation criterion such as temperature and water chemistry conditions. The experimental results show that the passivation was completed successfully.

목차
Abstract
 1. 서론
 2. 재료 및 방법
  2.1 핵연료 노내조사시험설비
  2.2 수질제어
  2.3 부동태 처리 제한기준
 3. 부동태 처리
 4. 결과 및 고찰
 5. 결론
 참고문헌
저자
  • 안성호(한국원자력연구원 하나로운영부) | S. H. Ahn
  • 이정영(한국원자력연구원 연구로설계부) | C. Y. Lee
  • 임성팔(한국원자력연구원 하나로운영부) | S. P. Yim
  • 정창용(한국원자력연구원 하나로운영부) | C. Y. Joung