This study analyzed concentration and characteristics of hazardous substances in treatment of leachate from carcass burial areas by using high temperature thermal desorption (HTTD). Concentrations of pollutants emitted from HTTD treatment of leachate contaminated soil of carcass burial sites satisfied the emission standards for 11 pollutants from domestic waste incineration facilities. Dioxin concentration was 0.0060 ng I-TEQ/Sm3 and 0.0061 (0.0055-0.0070) ng ITEQ/ Sm3 in the normal operation condition and the experimental condition, respectively, which are much lower than the MSWI Standard of 0.1ng I-TEQ/Sm3. As a result, it was considered that leachate from carcass burial areas could be treated by high temperature thermal desorption (HTTD).