논문 상세보기

아스팔트 도로포장에 물순환 파이프 시스템을 이용한 표면온도저감에 관한 연구 KCI 등재

A Study of the Surface Temperature Reduction Using Pipe Cooling System in Asphalt Pavement

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/250057
구독 기관 인증 시 무료 이용이 가능합니다. 4,300원
한국도로학회논문집 (International journal of highway engineering)
한국도로학회 (Korean Society of Road Engineers)
초록

PURPOSES: The purpose of asphalt pavement reducing surface temperature by using Pipe cooling system is to make pleasant city life environment. METHODS: We considered building condition to lay the pipes under asphalt pavement and figured out that temperature reducing effect with pipe cooling system. In addition, we guessed rutting through wheel tracking test with a laid the pipes under asphalt mixture and performed fatigue cracking through a flexural fatigue test for performance evaluation of pipe cooling system. RESULTS: When pipe cooling system worked, the temperature of pavement model reduced quickly in test. The system can turn down the degree by 4 or 5 quickly as well. It didn't affect rutting to lay the pipes under the pavement, but it can get damaged to asphalt pavement in early stage by the result of performance evaluation. CONCLUSIONS: We figured out that pipe cooling system can turn down the temperature of aspalt pavement surface through tests. We suggest that pipe cooling system should be considered one of the effective way to solve urban heat island problem.

저자
  • 윤용규 | Yoon, Yong Kyu
  • 박경원 | Park, Kyung Won
  • 이석근 | Lee, Suk Keun