Radiation Pattern of the Vibrox Transducer
Computer simulation results on the radiation pattern of an ultrasonic beam by the plurall arrangement of the transducers were reported by Sin (1979). This paper describes on the measurement of radiation pattern in case of one vibrox transducer and two vibrox transducers by varying the interval between the transducers. The measured results obtained are as follows; 1. Radiation wave of ultrasonic transducer is propagated to diffuse with spherical wave from center of transducer. 2. In case of one vibrox transducer, the greater the length of transducer, the sharper becomes the radiation pattern. 3. In case of two vibrox transducers, the maine lobe is revealed at the center of two transducers, it is shown difficult to make control freely of radiation pattern by varying merely the interval of transducers.