Because of the sharp increase of its export and import container cargo volumes contrast to the lack of related Container Terminal facility, equipment and inefficient procedure, there is now heavy container cargo congestions in Pusan Container Terminal. As a result of such a situation, many container ships avoid their calls into Pusan port. This is a major cause that in tum kads to weakening intemational competitiveness of the Korean industry. This study, therefore, aims are to make a quantitative analysis of Container Terminal System through the computer simulation, especially focusing on its 4 sub-system of a handling system, 'it is checked whether the current operation is being performed effectively through the computer simulation. The overall findings are as folIows; Firstly, average tonnage of the ships visiting the BCTOC was 32,360 G/T in from January '96, to may '96. The average arrival interval and service time of container ships at BCTOC are 5.63 hours and 18.67 hours respectively. Ship's arrival and service pattern at BCTOC was exponential distribution with 95% confidence and Erlang-4 distribution with 99% confidence. Secondly, average waiting time and number of ships was 9.9 hours, 235 ships(38%) among 620 ships. Number of stevedoring container per ship was average 747.7 TED, standard deviation 379.1 TEU and normal distribution with 99% confidence. Thirdly, from the fact that the average storage days of containers at BCTOC are 2.75 days (3.0 days when import, 2.5 days when export). it is founds that most containers were transfered to the off-dock storage areas with the free periods(5 days when import, 4 days when export), the reason for which is considered to be the insufficient storage area at BCTOC. Fourthly, in the case of gate in-out at BCTOC, occupied containers and emptied containers are 89% and 11% respectively in the gate-in, 75% and 25% seperately in the gate-out. Finally, from the quantitative analysis results for container terminal at BCTOC, ship's average wating time of ships was found to be 20.77 hours and berth occupancy rate(σ) was 0.83. 5~6 berths were required in order that the berth occupancy rate(σ) may be maintained up to 60% degree.