논문 상세보기

항만센서용 수정진동자의 해수에 의한 부식

Corrosion of Quartz Crystal Marine Sensors in Sea Water

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/261810
서비스가 종료되어 열람이 제한될 수 있습니다.
Journal of Korean Port Research (한국항만학회지)
한국항해항만학회 (Korean Institute of Navigation and Port Research)
초록

A quartz crystal analyzer is utilized to monitor the corrosion process of an aluminum surface of a quartz crystal for marine sensor by sea water. A quartz crystal having 2000 a of aluminum layer is installed in a specially designed cell and is in contact with sea water imitated electrolyte solution. While a constant potential is applied to the cell, the resonant frequency and resonant resistance are simultaneously measured using the quartz crystal analyzer. In addition, surface topographs are taken with an atomic force microscope(AFM) and the element analysis of the surface is conducted using an energy dispersive X-ray spectrometer(EDX). The simultaneous measurement of resonant frequency and resonant resistance during the corrosion process explains the change of surface structure caused by the corrosion. The variation of resonant frequency addresses the amount surface metal dissolution. As a conclusion, it is found that a simple measurement using the quartz crystal analyzer can replace the complex monitoring employing large equipments in the investigation of a corrosion process of sensor surface.

저자
  • 최광재
  • 장상목
  • 김영한