초록

Existing non-destructive test for evaluation of concrete compressive strength may show deviation in results analysis due to deterioration of precision by strength calibration and dry or humid condition by age, so there needs be testing method to determine long term structural internal force by collecting specimen with no damage of structure and measuring compressive strength through destruction test. This research applied to mock-up member the compressive strength evaluation method using joint separation mold that can plan and produce specimen cured in the same composition environment as concrete structure by attaching arbitrary(joint separation) to the form before concrete piling, and as a result, the management specimen was contrary to the hydration temperature of the member or was affected by external atmospheric temperature, however the joint separation specimen connected to structure and managed in the same environment showed a temperature curve similar to the member and decrease in temperature difference. Additionally, from initial age, with the compressive strength of joint separation specimen most similar to core strength,stable compressive strength can be evaluated up to design criteria strength 100MPa, so the method is proposed as an evaluation technique that can confirm highly reliable concrete quality.

저자
  • 기전도(단국대학교 대학원 건축공학과 대학원 석사과정) | Ki, Jun-Do Corresponding author
  • 김학영(단국대학교 대학원 건축공학과 대학원 박사과정) | Kim, Hak-Young
  • 정상진(단국대학교 건축대학 건축공학과 정교수,공학박사) | Jung, Sang-jin