The purpose of this study is to verify the transfer function of input acceleration and output control force based on linearizing a damping term of Tuned Liquid Column Damper(TLCD) with nonlinearity analytically. In addition, analysis is conducted for dynamic characteristics according to the design parameter such as section ratio of both vertical and horizontal column and the level of liquid in the vertical column which is used for tuning method. The dynamic characteristics is identified by the analysis for the natural frequency, damping ratio and effective mass ratio of TLCD and a shaking table test for the transfer function. The results indicates that the level of liquid and section ratio affect the characteristics of damping ratio and mass ratio. Damping and mass ratio increase as the section of vertical column of TLCD decreases due to turbulence in the elbow of TLCD.