In order to obtain the flexural and shear performance capacity of newly developed WAffle Slab(WAS) System, 14 full-scale 1.98mx10.00m specimens were tested under monotonic load. The Flexural performance was observed and compared with the conventional double-tee slab system using the test result. The shear performance was observed W AS slab using the test result. lt was confirmed that WAS system has enough flexural and shea capacity to carry the design load. Destruction features of test result, it appeared with bending destruction on the whole. According to steel wire increase, tolerance force's also increased. But steel wire increases to follow, it appears brittle destruction aspect. Case of shear test, the stirrup interval to be narrow maximum load appeares the tendency which comes to be destroyed.