초록

Because a smart isolation system cannot be used as a base isolation system for tall buildings, top-story or mid-story isolation systems are required. In this study, adaptability of a smart top-story isolation system for reduction of seismic responses of tall buildings in regions of low-to-moderate seismicity has been investigated. To this end, 20-story example building structure was selected and an MR damper and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes generated based on design spectrum of low-to-moderate seismicity regions are used for structural analyses. Based on numerical simulation results, it has been shown that a smart top-story isolation system can effectively reduce both structural responses and isolation story drifts of the building structure in low-to-moderate seismicity regions in comparison with a passive top-story isolation system.

목차
 Abstract  1. 서 론  2. 수치해석모델   2.1 20층 빌딩 예제구조물   2.2 최상층 면진시스템의 구성   2.3 중약진 지역의 인공지진하중  3. 제어알고리즘의 개발  4. 지진응답 제어성능 평가  5. 결론  감사의 글  참고문헌
저자
  • 김현수(선문대학교 건축학부 조교수) | Kim, Hyun-Su
  • 강주원( 영남대학교 건축학부 교수) | 강주원