논문 상세보기

원전 EQS 면진장치의 성능개선을 위한 연구 KCI 등재

Study on the Performance Improvement of an EQS Device Applied Nuclear Power Plant

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/285137
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
한국지진공학회 (Earthquake Engineering Society of Korea)
초록

This paper presents the performance improvement of an EQS (Eradic Quake System) device applied to a nuclear power plant. For the nuclear facility, the EQS device needs to be ensured to have high quality, flexibility of design and reliability. To improve the reliability of the design, the hysteresis of the device must be exactly predicted. The friction coefficient of PTFE (PolyTetraFluoroEthylene) and the stiffness of the MER-Spring are considered as the factors influencing the hysteresis curve. In this paper, those factors are analysed to predict the behavior of the device and to improve the equipment of the EQS device. The results of the improved EQS device have been verified via a tests to be comparable with the predicted results. The estimation results indicate that considering those factors is more appropriate than the results of the previous design and method.

저자
  • 이유인((주)에스코알티에스) | Lee, You In
  • 이유진( (주)에스코알티에스) | 이유진
  • 이홍표( 한수원(주) 중앙연구원) | 이홍표
  • 조명석( 한수원(주) 중앙연구원) | 조명석
  • 지용수( (주)에스코알티에스) | 지용수
  • 백준호( (주)에스코알티에스) | 백준호