Ultrasonic Velocity Evaluation of Concrete Considering Load Conditions and Micro Pore Structure
In this paper, ultrasonic velocity(UV) test through OPC and Slag concrete is conducted considering porosity under compressive and tensile loading conditions. The test results show that up to 50% of compressive loading condition, UV a little increases and remarkably drops at peak load, however it fluctuates under the tensile loading condition because of the number of increase micro cracks in concrete specimens.