In this paper, it is evaluated for sound and cold joint concrete under compressive load. To evaluate the permeability of the concrete, to prepare a cold joint specimens. And the water permeability evaluated by comparison of the sound and the cold joint concrete. it selected control, 30%, and 60% of the breaking strength. Results of evaluating the permeability of the cold joint concrete under compressive load, and tended to reduce at 30% of load, to increase at 60% of load.