논문 상세보기

나트륨 히트파이프의 작동 특성 및 성능에 관한 실험적 연구 KCI 등재

An Experimental Study on the Operational Characteristics and Performance of the Sodium Heat Pipe

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/291746
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
한국기계기술학회지 (Journal of the Korean Society of Mechanical Technology)
한국기계기술학회 (Korean Society of Mechanical Technology)
초록

The experimental study for an operational characteristics and performance of the sodium heat pipe were carried out. For an experiment, the heat pipe which is 1000mm length and 25.4mm diameter of stainless steel container with 50 mesh of screen wick using sodium as a working fluid is manufactured and tested as functions of heat flow rate, inclined angle and operating temperature. The test results are as follows. During the start-up, frontal start up was observed because of the vapor density increasing as increased the hot zone. Also, the heat pipe showed uniform temperature over than 420℃ of the operating temperature. The average heat transfer coefficient increased as the heat flux and the vapor temperature increase, and the range of the total thermal resistance was 0.075~0.04℃/W at the 12~53.55kW/m2 of heat flux and 500~750℃ of operating temperature. The maximum heat flow rate was 750W at the 10 degree of top heating mode.

목차
Abstract
 1. 서론
 2. 실험 장치 및 실험 방법
  2.1 실험 장치
  2.2 실험 방법
 3. 실험 결과 및 고찰
  3.1 나트륨 히트파이프의 시동 특성
  3.2 나트륨 히트파이프의 작동 특성
  3.3 나트륨 히트파이프의 한계 특성
 4. 결론
 References
저자
  • 강환국(동은에이티에스) | Hawn Kook Kang
  • 조운(용인송담대학교 자동차기계과) | Woon Cho Corresponding Author