전자제어 밸브(ECV) 내부로 유입되는 냉매의 유동 특성에 관한 연구 KCI 등재

A Study on the Refrigerant Flow Characteristics Flowing into the Interior of the Electromagnetic Control Valve

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/291792
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
한국기계기술학회지 (Journal of the Korean Society of Mechanical Technology)
한국기계기술학회 (Korean Society of Mechanical Technology)
초록

In this paper, we analyzed the characteristics of the mass flow rate and velocity of the refrigerant in response to a change in the number of holes and the diameter size(Type-1~4) of the valve guide refrigerant to flow from Pc to Ps when the pressure is constant. Type-1 is 40% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate. Type-2 is 64% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate. Type-3 is 50% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate. Type-4 is 47% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate.

목차
Abstract
 1. 서론
 2. 유동 해석 모델 및 조건
 3. 유동 해석 결과
  3.1 Type-1
  3.2 Type-2
  3.3 Type-3
  3.4 Type-4
 4. 결론
 후기
 References
저자
  • 김대영(국립 공주대학교 대학원 기계공학과) | D. Y. Kim
  • 조행묵(국립 공주대학교 기계자동차공학부) | H. M. Cho Corresponding Author