Flexural Performance of Steel and Synthetic Fibers in Dry Cast Concrete Mixture

드라이 캐스트 콘크리트 혼합물 내부 스틸 및 합성섬유의 휨 성능

  • 언어ENG
  • URLhttps://db.koreascholar.com/Article/Detail/292113
서비스가 종료되어 열람이 제한될 수 있습니다.
한국구조물진단유지관리공학회 (The Korea Institute For Structural Maintenance and Inspection)
초록

This paper presents the comparison of the test results for material behavior for dry cast steel and synthetic fiber reinforced concrete. ASTM C1609 flexural beam test were carried out for two different fiber dosages of synthetic and steel fibers. Synthetic and steel fiber dosages were 2.4 kg/m3 and 13.1 kg/m3, respectively. From the results of tests, material properties were found including; compressive strength, first-peak load, peak load, and specimen toughness. ASTM beam load- deformation plots were obtained for each fiber beam to show the fiber behavior and strengthening after the initial crack.