In this study, various difference sizes of lightweight fine aggregates were used to make concrete
specimens. The pressure waves, ultrasonic velocity and maximum frequency were measured for the specimens. Initial ultrasonic velocities were influenced by the sizes of lightweight fine aggregates, but not by the maximum frequency bandwidth.