Wireless monitoring system was established to measure PPWS(Prefabricated Parallel Wire Strand) temperature under PPWS erection in Ulsan Grand bridge. The applicability of it to bridge construction site was being evaluated. Wireless function was worked very well within 2km long distance. Transferred data was being analyzed.