As the building maintenance and safety management have recently been brought to attention, the utilization of non-destructive testing methods for internal inspection of concretes is increasing. Non-destructive testing methods, unlike typical destructive testing methods that deconstruct or cut the building in case of issues such as pores, heterogeneous material, cracks or any such equivalent issues inside/outside the building, refer to the testing methods for pores, heterogeneous material, or defectiveness occurring in the specimen without changes or destruction of internal structure using ultrasound, radiation, electromagnetism, fluid, heat, or light. In this study, among such non-destructive testing methods, the impact echo method was used for an experiment to estimate the steel rebar location and thickness in the concrete mock member.