초록

Adaptability of a smart top-story isolation system for reduction of seismic responses of tall buildings in regions of low-to-moderate seismicity has been investigated in this study. To this end, 20-story example building structure was selected and an MR damper and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes generated based on design spectrum of low-to-moderate seismicity regions are used for structural analyses.

저자
  • 김현수(선문대학교 건축학부 조교수, 공학박사) | Kim, Hyun-Su Corresponding Author