The SPC wall girder is connected to the vertical walls to enhance performance of wall-wall girder connection. The purpose of this study is to investigate the structural characteristics such as strength, Load-displacement relation of wall-wall girder connection under the cyclic load tests. The fracture pattern of the specimens was steel plate separation from concrete in SPC Wall induction of tensile crack failure of SPC Wall concrete.