Flow Analysis of MEMS-based Micro Pump
This research is to investigate the flow characteristics of micropump with two different types of diffuser outlet in micropump (straight and round). Four different outlet diameters(1mm, 1.5mm, 2mm at straight type of diffuser outlet and single outlet diameter(1mm) at round type are utilized for the flow analysis of the diffuser in micropump. Velocity and pressure distributions of fluid over the flow domain are numerically calculated for the shape optimum design of diffuser in micropump with uniform inlet velocity and pressure. According to the calculations of local maximum pressure at diffuser outlet, straight type of diffuser with larger diameter of diffuser outlet is of highest flow energy performance of the flow channel shapes in the present micropump.